Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Abstract 23079: Clinical Outcomes of Transcatheter Mitral Valve Replacement for Degenerated Mitral Bioprostheses (Mitral Valve-in-Valve) and Surgical Rings (Mitral Valve-in-Ring) in the United States: Data From the STS/ACC/TVT Registry
Introduction: Transcatheter mitral valve replacement (TMVR) using aortic transcatheter heart valves (THV) is developing as an alternative to surgery for patients with severe mitral valve disease due to degenerated mitral bioprostheses or failed surgical rings who are poor surgical candidates. Outcomes of off-label procedures in the United States are being collected in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy (STS/ACC TVT) Registry. A comprehensive analysis of mitral Valve-in-Valve (VIV) versus Valve-in-Ring (VIR) outcomes has not previously been performed. Objectives: To evaluate in-hospital and 30-day clinical outcomes of mitral VIV and VIR procedures in the United States. Methods: Retrospective analysis of data from the STS/ACC TVT Registry on patients who underwent mitral VIV or VIR procedures. Results: 587 patients underwent TMVR VIV (n=494) or VIR (n=93) procedures between January 2013 and December 2016 at 144 hospitals. Median age was 76 (VIV) and 73 (VIR) years, (p=0.024), 60.9% (VIV) and 44.1% (VIR) were female (p=0.003), median left ventricular ejection fraction was 55% in VIV and 50% in VIR (p <0.001), and median STS score was 10.5% (VIV) and 9.2% (VIR), p=0.131. Transseptal access was utilized in 35% VIV and 46.2% VIR procedures, p=0.081. Procedural success was achieved in 74.4% of VIV and 57.8%VIR (p=0.239). Left ventricular outflow tract (LVOT) obstruction was more common in VIR (5.4%) vs VIV (0.06%), p=0.003. Post-procedure median mean mitral valve gradient was 4mmHg in both groups. 95.7% of VIV and 86% of VIR patients had post-procedure mitral regurgitation ≤1(+), p<0.001. In-hospital mortality was 6.9% for VIV and 9.7% for VIR (p=0.343). 30-day mortality was 9% for VIV and 12% for VIR (p=0.387). At 30-day follow up, 85.6% of VIV and 77.7% of VIR patients were in New York Heart Association class I or II (p=0.398). Conclusions: TMVR VIV and VIR using aortic transcatheter heart valves in high surgical risk patients are associated with similar in-hospital and 30-day mortality and symptom benefit. LVOT obstruction post-TMVR and residual mitral regurgitation ≥2 (+) were more frequent in VIR procedures. The long-term effect of these procedures is not known and requires further evaluation.
Short‐ and mid‐term outcomes in percutaneous mitral valve replacement using balloon expandable valves
AbstractBackgroundDue to elevated surgical risk, transcatheter mitral valve replacement (TMVR) is used as an alternative for treating failed bioprosthetic valves, annuloplasty repairs and mitral annular calcification (MAC). We report the procedural and longitudinal outcomes for each subtype: Mitral valve‐in‐valve (MVIV), mitral valve‐in‐ring (MViR), and valve‐in‐MAC (ViMAC).MethodsConsecutive patients undergoing TMVR from October 2013 to December 2019 were assessed. Patients at high risk for left ventricular outflow tract obstruction had either alcohol septal ablation or intentional laceration of the anterior leaflet (LAMPOON).ResultsEight‐eight patients underwent TMVR; 38 MViV, 31 MViR, and 19 ViMAC procedures were performed. The median Society of Thoracic Surgery 30‐day predicted risk of mortality was 8.2% (IQR 5.2, 19.9) for all. Sapien 3 (78%) and transseptal access (98%) were utilized in most cases. All‐cause in‐hospital mortality, technical, and procedural success were 8%, 83%, and 66% respectively. Median follow up was 1.4 years (IQR 0.5–2.9 years) and overall survival was 40% at 4 years. Differential survival rates were observed with MViV doing the best, followed by MViR and ViMAC having a <20% survival at 4 years. After adjusting for co‐variates, MViV procedure was the strongest predictor of survival (HR 0.24 [95% CI 0.079–0.7]).ConclusionTMVR is performed in at high‐risk patients with attenuated long‐term survival. MViV has the best success and survival rate, but long‐term survival in MViR and ViMAC is guarded.
Early outcomes from the
CLASP IID
trial roll‐in cohort for prohibitive risk patients with degenerative mitral regurgitation
Thirty-Day Outcomes of Transcatheter Mitral Valve Replacement for Degenerated Mitral Bioprostheses (Valve-in-Valve), Failed Surgical Rings (Valve-in-Ring), and Native Valve With Severe Mitral Annular Calcification (Valve-in-Mitral Annular Calcification) in
Background: Transcatheter mitral valve replacement using aortic transcatheter heart valves has recently become an alternative for patients with degenerated mitral bioprostheses, failed surgical repairs with annuloplasty rings or severe mitral annular calcification who are poor surgical candidates. Outcomes of these procedures are collected in the Society of Thoracic Surgeons/American College of Cardiology/Transcatheter Valve Therapy Registry. A comprehensive analysis of mitral valve-in-valve (MViV), mitral valve-in-ring (MViR), and valve-in-mitral annular calcification (ViMAC) outcomes has not been performed. We sought to evaluate short-term outcomes of early experience with MViV, MViR, and ViMAC in the United States. Methods: Retrospective analysis of data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Results: Nine hundred three high-risk patients (median Society of Thoracic Surgeons score 10%) underwent MViV (n=680), MViR (n=123), or ViMAC (n=100) between March 2013 and June 2017 at 172 hospitals. Median age was 75 years, 59.2% female. Technical and procedural success were higher in MViV. Left ventricular outflow tract obstruction occurred more frequently with ViMAC (ViMAC=10%, MViR=4.9%, MViV=0.7%; P <0.001). In-hospital mortality (MViV=6.3%, MViR=9%, ViMAC=18%; P =0.004) and 30-day mortality (MViV=8.1%, MViR=11.5%, ViMAC=21.8%; P =0.003) were higher in ViMAC. At 30-day follow-up, median mean mitral valve gradient was 7 mm Hg, most patients (96.7%) had mitral regurgitation grade ≤1 (+) and were in New York Heart Association class I to II (81.7%). Conclusions: MViV using aortic balloon-expandable transcatheter heart valves is associated with a low complication rate, a 30-day mortality lower than predicted by the Society of Thoracic Surgeons score, and superior short-term outcomes than MViR and ViMAC. At 30 days, patients in all groups experienced improvement of symptoms, and valve performance remained stable. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02245763.
Complete percutaneous apical access and closure: Short and intermediate term outcomes
AbstractObjectivesTo examine the safety of utilizing transapical access during structural interventions.BackgroundComplex interventions of the mitral or aortic region sometimes require coaxial forces to orient and deliver devices. Apical access can provide coaxial countertraction for either transseptal or retrograde aortic access. This manuscript describes the single center experience of small bore transapical access.MethodsRetrospective review of cases from 2013 to 2018 at Henry Ford Hospital was performed. Patient demographics and procedure characteristics were abstracted to describe the safety of transapical access using small bore sheaths.ResultsA total 21 cases were performed at Henry Ford, most of them for transcatheter mitral valve replacement (81%). The mean sheath size used was 4.7 ± 0.9 Fr and protamine was used at the end of 57% of cases. All patients received nitinol‐based plugs, 80.1% were from the Amplatz Duct Occluder II type. Four major complications related apical puncture occurred, two pericardial effusions, two hemothorax. Over a median follow time of 430 days (IQR 50–652) a total of five deaths occurred, two related to the procedure and three late deaths with a median time of 362 days (range 205–628 days). No deaths were associated with transapical access. Echocardiographic follow up did not detect any late structural complications from occluder devices.ConclusionsTransapical access and closure with nitinol‐based devices is feasible and facilitates complex interventions where coaxial forces are need for device delivery and alignment. The most common complication is bleeding and this should be kept in perspective when treating high‐risk patients.
Pivotal Clinical Study to Evaluate the Safety and Effectiveness of the MANTA Percutaneous Vascular Closure Device
Background: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device. Methods and Results: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%). Conclusions: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.