BACKGROUND: A preservation system, the Organ Care System (OCS; TransMedics) uses normothermic pulsatile perfusion during organ transport for heart transplantation. This system has demonstrated favorable outcomes in hearts recovered from extended-criteria donors after brain death (DBD) and donors after circulatory death (DCD). METHODS: The OCS Heart Perfusion Registry collects data on US heart transplantations using the OCS, static cold storage (SCS), or thoracoabdominal normothermic regional perfusion (NRP) and donor hearts recovered from DBD or DCD donors. We analyzed donor and recipient characteristics and posttransplantation outcomes in patients transplanted with OCS donor hearts (either DBD or DCD) compared with SCS hearts, and with OCS hearts from DCD donors compared with those recovered with NRP followed by SCS. Propensity score matching was used in survival analyses to adjust for differences among recipient characteristics. RESULTS: Between 2021 and 2023, 3225 consecutive heart transplantations enrolled from 56 centers were analyzed in the Heart Perfusion Registry. The OCS was used in 854 of 3225 heart transplantations (26.4%), among which 340 (39.8%) were DBD and 514 (60.2%) were DCD donors, whereas 2174 DBD donors were recovered with SCS and another 197 DCD donors with NRP techniques. The OCS-DBD group experienced a greater number of organ offer refusals before final acceptance (13 versus 6; Wilcoxon rank sum, P <0.001) and a longer transport distance (667 miles versus 232 miles; Wilcoxon rank sum, P <0.001) compared with SCS-DBD. Survival at 12 months was similar between the 2 groups (89.9% for OCS-DBD versus 90.6% for SCS-DBD; marginal Cox model, P =0.54). Among the OCS-DCD and SCS-DBD groups, survival at 12 months was also similar (91.0% versus 92.5%, respectively; marginal Cox model, P =0.32). The OCS-DCD and NRP-DCD groups demonstrated similar survival (91.0% versus 91.7%, respectively; log rank, P =0.63), although the transport distance was longer in OCS-DCD compared with DCD with NRP followed by SCS (400 miles versus 223 miles; Wilcoxon rank sum, P <0.001). By 2023, 90% of all OCS donor management and recovery was performed with dedicated organ recovery teams. CONCLUSIONS: We demonstrate that real-world implementation of the OCS for DBD donors (using predominantly a dedicated recovery team) is associated with expanded donor criteria, longer transport distance, and excellent posttransplantation outcomes. In OCS-DCD donors, outcomes parallel those of donors recovered with NRP-DCD and compare favorably with DBD donor organs.
Transplantation Outcomes with Donor Hearts after Circulatory Death
Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P &lt; .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P &lt; .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P &lt; .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Abstract 18299: Device Selection: Does Ventricular Size Matter in LVAD Recipients?
Introduction: Axial and centrifugal-flow left ventricular assist devices (LVAD) have varied response to changes in loading conditions. Whether ventricular size modulates the response to LVAD therapy between the axial flow Heartmate II (HMII) and centrifugal flow Heartware (HVAD) is unknown. Hypothesis: Adverse event and survival rates between devices are affected by recipient pre-op left ventricular end-diastolic diameter (LVEDD). Methods: Data on 1,149 continuous-flow LVAD recipients from May 2004 to May 2015 was pooled from the Mechanical Circulatory Support Research Network (MCSRN). The effect of pre-op LVEDD on the instantaneous hazard of death and adverse events was evaluated between HMII (n=864) and HVAD (n=283). Results: The average LVEDD was 7.0cm and did not differ between the device recipients. Patients with a smaller LVEDD (≤ 6.3cm) were more likely female 39% v. 24% (p < 0.0001) and to have an ischemic cardiomyopathy (30% v. 24%, p = 0.045). For every 1cm increase in pre-op LVEDD, the adjusted hazard ratio (HR) for mortality increased with HVAD (HR 1.31, 95% CI 0.94-1.82, p = 0.005) and decreased with HMII (HR 0.78, 95% CI 0.67-0.92, p = 0.005), Figure 1a. Other predictors of mortality included age (HR 1.31, 95% CI 1.12 - 1.53 per 10y, p < 0.001) and bilirubin (HR 1.15, 95% CI 0.94-1.42 per mg/dL, p = 0.027). LVEDD by device type interaction was not a significant predictor of gastrointestinal bleeding or pump thrombosis. The risk of stroke increased with LVEDD for HVAD and decreased for HMII, but this did not reach statistical significance, Figure 1b. Ischemic etiology of heart failure (HR 1.7 95% CI 1.14 - 2.55, p = 0.01) and HVAD device use (HR 1.47 95% CI 1.00 - 2.17, p = 0.03) were significant predictors of stroke. Conclusions: Our data suggest important differences exist in patient outcomes between HMII and HVAD based on pre-op ventricular size. Studies are needed to determine if these differences in outcome are due to device or flow-specific differences in patient support.
Impact of Patient Distance From Ventricular Assist Device–Implanting Center on Short- and Long-Term Outcomes
Highly specialized left ventricular assist device care is not readily available in many areas, potentially limiting access to therapy. This retrospective analysis examines the relationship of outcomes by patient distance from implanting left ventricular assist device center within the Mechanical Circulatory Support Research Network. Zip codes were used to calculate patient distance, with the primary outcome of interest being 3-year survival by distance from the surgical center. Secondary outcomes included 90-day survival and incident event rates for the following: gastrointestinal bleeding, infection, cerebral event, and pump thrombosis. Across the four centers, there were 1184 patients supported for a median of 486 days. Overall survival was 91 ± 0.8% at 90 days and 61 ± 1.9% at 3 years, with worse 3-year survival in those living >90 vs . ≤90 miles from the ventricular assist device implant center (55 ± 3.0% vs . 64 ± 2.5, p = 0.019). Patients living >90 miles from an implant center were older, more likely to be implanted for destination therapy support, had a prior sternotomy, and had worse renal function than those living closer ( p <0.05 for all). After adjusting for these factors, albumin and center of implant, the hazard ratio did not reach statistical significance (hazard ratio = 1.2; p = 0.14). Except for gastrointestinal bleeding, the event rates for the secondary outcomes were higher for those living closer to the implanting center. Protocols should be designed for more frequent follow-up and increased shared care opportunities to ensure optimal outcomes are achieved in distant patients.
Left Lateral Thoracotomy for Centrifugal Continuous-Flow Left Ventricular Assist Device Placement: An Analysis from the Mechanical Circulatory Support Research Network
Continuous-flow left ventricular assist devices (CF-LVADs) have revolutionized the management of patients with advanced heart failure. Alternative implant strategies are increasingly used for device placement. We reviewed our experience from the Mechanical Circulatory Support Research Network registry with the HeartWare centrifugal CF-LVAD (HVAD). From May 2004 to August 2015, 1,150 patients underwent primary CF-LVAD implantation at our institutions. Within this group, a total of 283 patients (25%) were implanted with the HVAD. A minimally invasive left lateral thoracotomy (MILT) implant strategy was used in 53 patients (20%), of which 22 (42%) were implanted off-pump. Median age at implant was 59 years and 183 patients (65%) were implanted as bridge-to-transplantation. Follow-up was 100% complete for a total of 302 patient-years of support. In-hospital mortality was 4.9% (14 patients), and was comparable between the conventional sternotomy (CS) and MILT cohorts (p = 0.15). Patients in the MILT cohort had a shorter median length of stay (p < 0.01) and had a lower incidence of postimplant pump thrombus (p = 0.02). Cumulative survival at the end of follow-up reached 84%, and was comparable between the two groups (p = 0.298). Multivariate analysis identified preoperative bilirubin level as the only independent predictor of survival. Surgical technique had no impact on survival. In this large, multicenter experience, data demonstrate excellent survival and adverse event profiles for patients supported with the HVAD technology, regardless of surgical implant technique. With constant advancements in device technology along with our increasing clinical experience with the newer techniques, minimally invasive LVAD implantation continues to evolve as a valuable alternative to CS in selected patients.