Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Computed Tomography–Based Indexed Aortic Annulus Size to Predict Prosthesis-Patient Mismatch
Background: Hemodynamic performance of prostheses after transcatheter aortic valve replacement (TAVR) is generally better than after surgical aortic valve replacement (SAVR), especially in patients with a small native annulus size. However, it remains unclear whether differences are consistent for patients with a different propensity for developing prosthesis-patient mismatch (PPM), considering annulus size and body size of patients. Methods and Results: The SURTAVI trial (Surgical Replacement and Transcatheter Aortic Implantation) compared TAVR using a self-expandable valve with SAVR in intermediate-risk patients. Multidetector computed tomography–based aortic annulus size consisted of the perimeter-derived diameter, which was divided by body surface area to produce an indexed annulus size. Patients were categorized into a small (9–12 mm/m 2 ), medium (>12–14 mm/m 2 ), and large (>14–18 mm/m 2 ) group according to indexed annulus size. We compared TAVR and SAVR for PPM, hemodynamics, and clinical, and functional outcomes through 1-year follow-up within the size groups. Patients who underwent TAVR received a larger prosthesis with increasing indexed annulus size ( P <0.001), while there was no difference in prosthesis size in patients who underwent SAVR ( P =0.74). Patients in all size groups had significantly larger indexed effective orifice area and lower mean gradients at discharge after TAVR versus SAVR. Rates of PPM were significantly lower with TAVR versus SAVR in all groups ( P <0.001) and declined with larger indexed annulus sizes with both TAVR ( P =0.04) and SAVR ( P =0.03). Indexed annulus size was an independent predictor of PPM after TAVR and SAVR. Clinical outcomes were comparable between TAVR and SAVR across all groups, apart from a significantly higher rate of reintervention after TAVR versus SAVR in the large indexed annulus size group (2.5% versus 0%; P =0.01) but without significant interaction ( P int =0.81). Conclusions: Rates of PPM were significantly lower after TAVR than after SAVR across all groups of indexed annulus size, reflecting better hemodynamic performance of transcatheter versus surgical valves, irrespective of the propensity to develop PPM. More attention should be directed to prevention of PPM after SAVR. This information should be considered by the Heart Team to recommend a specific procedure or valve. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT01586910.
Outcomes From Transcatheter Aortic Valve Replacement in Patients With Low-Flow, Low-Gradient Aortic Stenosis and Left Ventricular Ejection Fraction Less Than 30%