Importance Transcatheter tricuspid valve replacement (TTVR) demonstrated superior outcomes over medical therapy in patients with severe tricuspid regurgitation (TR) in the Edwards EVOQUE Transcatheter Tricuspid Valve Replacement: Pivotal Clinical Investigation of Safety and Clinical Efficacy Using a Novel Device II (TRISCEND II) randomized clinical trial, and received regulatory approval in the US in 2024. Contemporary real-world data on its effectiveness and safety remain limited. Objective To evaluate 30-day clinical, echocardiographic, and health status outcomes of TTVR in real-world use. Design, Setting, and Population Retrospective cohort study of all consecutive patients who underwent TTVR in the US from February 2024 through March 2025 in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Patients had symptomatic, severe TR despite optimal medical therapy and TTVR was deemed appropriate by a heart team. Statistical analysis was conducted from September 2025 to February 2026. Exposure Device-enabled TTVR. Main Outcomes and Measures Thirty-day event rates (all-cause death, stroke, bleeding, new cardiac implantable electronic device [CIED] implantation, heart failure hospitalizations), TR reduction, and changes in health status (New York Heart Association [NYHA] functional class and Kansas City Cardiomyopathy Questionnaire Overall Summary [KCCQ-OS] score) are reported. Subgroup analyses examined the impact of baseline CIED status on outcomes. Results Among 1034 attempted procedures at 82 centers (mean [SD] age, 77.1 [10.6] years; 69.1% female; 73.2% NYHA functional class III/IV), a valve was successfully implanted in 1017 patients (98.4%). Mild or less TR was achieved in 98.4% of patients post procedure and in 97.7% at 30 days. At 30 days, all-cause mortality was 3.1%; stroke, 0.2%; bleeding, 7.9%; new CIED, 15.9% in CIED-naive patients; and heart failure hospitalization, 3.1%. There were significant improvements in NYHA functional class (class I/II, 82.7%; P < .001) and mean KCCQ-OS score (22.4 points; P < .001) from baseline to 30 days. There were no significant differences in 30-day mortality ( P = .47), heart failure hospitalization ( P > .99), and functional outcomes ( P = .55) when patients were stratified by baseline CIED status. Conclusions and Relevance Early US real-world experience with TTVR confirms safety and effectiveness in patients with severe TR. Thirty-day outcomes are consistent with the TRISCEND II pivotal trial, demonstrating acceptable safety, near-complete TR elimination, and significant health status improvements in an older, comorbid population. Rates of new CIED implantation and bleeding were lower than randomized clinical trial experience.
Tricuspid valve replacement outcomes by baseline tricuspid regurgitation severity: the TRISCEND II trial
Abstract Background and Aims The TRISCEND II trial demonstrated superior clinical benefits for patients with ≥severe tricuspid regurgitation (TR) treated with the EVOQUE transcatheter tricuspid valve replacement (TTVR) system plus medical therapy vs medical therapy alone. This work reports 1-year and 18-month outcomes in patients stratified by baseline TR severity. Methods The multicentre, prospective TRISCEND II trial enrolled 400 patients with symptomatic, ≥severe TR, and randomized 2:1 to TTVR (n = 267) or control (n = 133). In a post hoc analysis, patients were stratified into severe TR (n = 172) and massive/torrential TR (n = 220) cohorts. Clinical and quality-of-life outcomes were reported at 1 year, with Kaplan–Meier estimates for all-cause mortality and heart failure (HF) hospitalization assessed at 18 months. Study oversight included an independent echocardiographic core laboratory, clinical events committee, and data safety monitoring board. Results One year after TTVR, TR was ≤mild in 95.2% of severe TR and 95.3% of massive/torrential TR patients. The primary safety and effectiveness endpoint (win ratio) favoured TTVR over control regardless of baseline TR severity: severe {1.64 [95% confidence interval (CI): 1.11, 2.43]} and massive/torrential [2.20 (1.55, 3.14)]. At 18 months, TTVR patients had similar mortality to controls [rate difference: severe 0.2% (−11.6, 11.9), massive/torrential −5.8% (−17.6, 6.0)], whereas HF hospitalization rates favoured TTVR in the massive/torrential cohort [vs control, severe 9.8% (−3.0, 22.7), massive/torrential -15.2% (−28.9, −1.5)]. Conclusions Patients with ≥severe TR benefit from TTVR, experiencing improvements in TR severity, functional capacity, and quality of life regardless of baseline TR severity, with a signal for greater benefit in patients with more advanced disease.
Structural Valve Deterioration After Self-Expanding Transcatheter or Surgical Aortic Valve Implantation in Patients at Intermediate or High Risk
ImportanceThe frequency and clinical importance of structural valve deterioration (SVD) in patients undergoing self-expanding transcatheter aortic valve implantation (TAVI) or surgery is poorly understood.ObjectiveTo evaluate the 5-year incidence, clinical outcomes, and predictors of hemodynamic SVD in patients undergoing self-expanding TAVI or surgery.Design, Setting, and ParticipantsThis post hoc analysis pooled data from the CoreValve US High Risk Pivotal (n = 615) and SURTAVI (n = 1484) randomized clinical trials (RCTs); it was supplemented by the CoreValve Extreme Risk Pivotal trial (n = 485) and CoreValve Continued Access Study (n = 2178). Patients with severe aortic valve stenosis deemed to be at intermediate or increased risk of 30-day surgical mortality were included. Data were collected from December 2010 to June 2016, and data were analyzed from December 2021 to October 2022.InterventionsPatients were randomized to self-expanding TAVI or surgery in the RCTs or underwent self-expanding TAVI for clinical indications in the nonrandomized studies.Main Outcomes and MeasuresThe primary end point was the incidence of SVD through 5 years (from the RCTs). Factors associated with SVD and its association with clinical outcomes were evaluated for the pooled RCT and non-RCT population. SVD was defined as (1) an increase in mean gradient of 10 mm Hg or greater from discharge or at 30 days to last echocardiography with a final mean gradient of 20 mm Hg or greater or (2) new-onset moderate or severe intraprosthetic aortic regurgitation or an increase of 1 grade or more.ResultsOf 4762 included patients, 2605 (54.7%) were male, and the mean (SD) age was 82.1 (7.4) years. A total of 2099 RCT patients, including 1128 who received TAVI and 971 who received surgery, and 2663 non-RCT patients who received TAVI were included. The cumulative incidence of SVD treating death as a competing risk was lower in patients undergoing TAVI than surgery (TAVI, 2.20%; surgery, 4.38%; hazard ratio [HR], 0.46; 95% CI, 0.27-0.78; P = .004). This lower risk was most pronounced in patients with smaller annuli (23 mm diameter or smaller; TAVI, 1.32%; surgery, 5.84%; HR, 0.21; 95% CI, 0.06-0.73; P = .02). SVD was associated with increased 5-year all-cause mortality (HR, 2.03; 95% CI, 1.46-2.82; P < .001), cardiovascular mortality (HR, 1.86; 95% CI, 1.20-2.90; P = .006), and valve disease or worsening heart failure hospitalizations (HR, 2.17; 95% CI, 1.23-3.84; P = .008). Predictors of SVD were developed from multivariate analysis.Conclusions and RelevanceThis study found a lower rate of SVD in patients undergoing self-expanding TAVI vs surgery at 5 years. Doppler echocardiography was a valuable tool to detect SVD, which was associated with worse clinical outcomes.Trial RegistrationClinicalTrials.gov Identifiers: NCT01240902, NCT01586910, and NCT01531374
Self-expanding Transcatheter vs Surgical Aortic Valve Replacement in Intermediate-Risk Patients
Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Early outcomes from the
CLASP IID
trial roll‐in cohort for prohibitive risk patients with degenerative mitral regurgitation