Importance Transcatheter tricuspid valve replacement (TTVR) demonstrated superior outcomes over medical therapy in patients with severe tricuspid regurgitation (TR) in the Edwards EVOQUE Transcatheter Tricuspid Valve Replacement: Pivotal Clinical Investigation of Safety and Clinical Efficacy Using a Novel Device II (TRISCEND II) randomized clinical trial, and received regulatory approval in the US in 2024. Contemporary real-world data on its effectiveness and safety remain limited. Objective To evaluate 30-day clinical, echocardiographic, and health status outcomes of TTVR in real-world use. Design, Setting, and Population Retrospective cohort study of all consecutive patients who underwent TTVR in the US from February 2024 through March 2025 in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Patients had symptomatic, severe TR despite optimal medical therapy and TTVR was deemed appropriate by a heart team. Statistical analysis was conducted from September 2025 to February 2026. Exposure Device-enabled TTVR. Main Outcomes and Measures Thirty-day event rates (all-cause death, stroke, bleeding, new cardiac implantable electronic device [CIED] implantation, heart failure hospitalizations), TR reduction, and changes in health status (New York Heart Association [NYHA] functional class and Kansas City Cardiomyopathy Questionnaire Overall Summary [KCCQ-OS] score) are reported. Subgroup analyses examined the impact of baseline CIED status on outcomes. Results Among 1034 attempted procedures at 82 centers (mean [SD] age, 77.1 [10.6] years; 69.1% female; 73.2% NYHA functional class III/IV), a valve was successfully implanted in 1017 patients (98.4%). Mild or less TR was achieved in 98.4% of patients post procedure and in 97.7% at 30 days. At 30 days, all-cause mortality was 3.1%; stroke, 0.2%; bleeding, 7.9%; new CIED, 15.9% in CIED-naive patients; and heart failure hospitalization, 3.1%. There were significant improvements in NYHA functional class (class I/II, 82.7%; P < .001) and mean KCCQ-OS score (22.4 points; P < .001) from baseline to 30 days. There were no significant differences in 30-day mortality ( P = .47), heart failure hospitalization ( P > .99), and functional outcomes ( P = .55) when patients were stratified by baseline CIED status. Conclusions and Relevance Early US real-world experience with TTVR confirms safety and effectiveness in patients with severe TR. Thirty-day outcomes are consistent with the TRISCEND II pivotal trial, demonstrating acceptable safety, near-complete TR elimination, and significant health status improvements in an older, comorbid population. Rates of new CIED implantation and bleeding were lower than randomized clinical trial experience.
Transcatheter Aortic Valve Implantation by Valve Type in Women With Small Annuli
Importance Historically, women with aortic stenosis have experienced worse outcomes and inadequate recognition compared to men, being both underdiagnosed and undertreated, while also facing underrepresentation in clinical trials. Objective To determine whether women with small aortic annuli undergoing transcatheter aortic valve replacement have better clinical and hemodynamic outcomes with a self-expanding valve (SEV) or balloon-expandable valve (BEV). Design, Setting, Participants The Small Annuli Randomized to Evolut or SAPIEN Trial (SMART) was a large-scale randomized clinical trial focusing on patients with small aortic annuli undergoing transcatheter aortic valve replacement, randomized to receive SEVs or BEVs and included 716 patients treated at 83 centers in Canada, Europe, Israel, and the US from April 2021 to October 2022. This prespecified secondary analysis reports clinical and hemodynamic findings for all 621 women enrolled in SMART. Data for this report were analyzed from February to April 2024. Interventions Transcatheter aortic valve replacement with an SEV or a BEV. Main Outcomes and Measures The composite coprimary clinical end point comprised death, disabling stroke, or heart failure–related rehospitalization. The coprimary valve function end point was the incidence of bioprosthetic valve dysfunction, both assessed through 12 months. Secondary end points included the incidence of moderate or severe prosthesis-patient mismatch. Results A total of 621 women (mean [SD] age, 80.2 [6.2] years; 312 randomized to the SEV group and 309 to the BEV group) were included in the present analysis. At 12 months, there were no significant differences in the coprimary clinical end point between the SEV and BEV groups (9.4% vs 11.8%, absolute risk difference −2.3%; 95% CI −7.2 to 2.5, P = .35). However, SEV implantation was associated with less bioprosthetic valve dysfunction (8.4% vs 41.8%; absolute risk difference, −33.4%; 95% CI, −40.4 to −26.4; P < .001). SEV implantation resulted in lower aortic valve gradients and larger effective orifice areas at 30 days and 12 months and less mild or greater aortic regurgitation at 12 months compared to BEV implantation. Prosthesis-patient mismatch was significantly lower with SEVs, regardless of the definition used and adjustment for body mass index. Use of SEVs was associated with better quality of life outcomes as assessed by the Valve Academic Research Consortium-3 ordinal quality of life measure. Conclusions and Relevance Among women with severe symptomatic aortic stenosis and small aortic annuli undergoing transcatheter aortic valve replacement, the use of SEVs, compared to BEVs, resulted in similar clinical outcomes and a markedly reduced incidence of bioprosthetic valve dysfunction through 12 months, including a lower risk of prosthesis-patient mismatch and better 12-month quality of life. Trial Registration ClinicalTrials.gov Identifier: NCT04722250