ABSTRACTBackgroundThe self‐expanding, supra‐annular Evolut valve is an established platform for Transcatheter Aortic Valve Implantation (TAVI). Evolut PRO introduced an outer sealing wrap to mitigate paravalvular leakage. We evaluated the 3‐year clinical outcomes and valve performance of the Evolut PRO in standard clinical practice for severe aortic stenosis (AS) patients at intermediate or higher risk for surgery.MethodsThe FORWARD PRO prospective, single‐arm, multicentre, post‐market clinical study enrolled 638 patients with native aortic valve stenosis or failed surgical bioprosthetic aortic valve undergoing TAVI, at intermediate or high risk, with the Evolut PRO valve. Clinical and serial echocardiographic outcomes were followed‐up for 3 years.ResultsTAVI using Evolut PRO was attempted in 629 AS patients (implanted in 97%) (mean age 81.7 years; STS PROM score, 4.7%). At 3 years all‐cause mortality was 25.0%, disabling stroke 6.5% (all‐cause mortality or disabling stroke, 28.5%) and rate of new permanent pacemaker implantation 24.7%. Excellent valve haemodynamics were maintained (mean gradient 8.8 ± 4.7 mm Hg; mean effective orifice area 2.0 ± 0.5 cm2) at 3 years. In a paired analysis of patients with ≥ mild paravalvular leakage (PVL) at discharge, more than two‐thirds demonstrated improved PVL at 3 years. Patients with ≥ mild PVL at discharge had higher median total calcium volume than those with no/trace PVL (p < 0.001).ConclusionsIn clinical practice TAVI with the Evolut PRO valve is associated with favorable clinical outcomes and excellent haemodynamic performance out to 3 years. The observation of improvements in PVL over time warrants further research.
Transcatheter Aortic Valve Implantation by Valve Type in Women With Small Annuli
Importance Historically, women with aortic stenosis have experienced worse outcomes and inadequate recognition compared to men, being both underdiagnosed and undertreated, while also facing underrepresentation in clinical trials. Objective To determine whether women with small aortic annuli undergoing transcatheter aortic valve replacement have better clinical and hemodynamic outcomes with a self-expanding valve (SEV) or balloon-expandable valve (BEV). Design, Setting, Participants The Small Annuli Randomized to Evolut or SAPIEN Trial (SMART) was a large-scale randomized clinical trial focusing on patients with small aortic annuli undergoing transcatheter aortic valve replacement, randomized to receive SEVs or BEVs and included 716 patients treated at 83 centers in Canada, Europe, Israel, and the US from April 2021 to October 2022. This prespecified secondary analysis reports clinical and hemodynamic findings for all 621 women enrolled in SMART. Data for this report were analyzed from February to April 2024. Interventions Transcatheter aortic valve replacement with an SEV or a BEV. Main Outcomes and Measures The composite coprimary clinical end point comprised death, disabling stroke, or heart failure–related rehospitalization. The coprimary valve function end point was the incidence of bioprosthetic valve dysfunction, both assessed through 12 months. Secondary end points included the incidence of moderate or severe prosthesis-patient mismatch. Results A total of 621 women (mean [SD] age, 80.2 [6.2] years; 312 randomized to the SEV group and 309 to the BEV group) were included in the present analysis. At 12 months, there were no significant differences in the coprimary clinical end point between the SEV and BEV groups (9.4% vs 11.8%, absolute risk difference −2.3%; 95% CI −7.2 to 2.5, P = .35). However, SEV implantation was associated with less bioprosthetic valve dysfunction (8.4% vs 41.8%; absolute risk difference, −33.4%; 95% CI, −40.4 to −26.4; P &lt; .001). SEV implantation resulted in lower aortic valve gradients and larger effective orifice areas at 30 days and 12 months and less mild or greater aortic regurgitation at 12 months compared to BEV implantation. Prosthesis-patient mismatch was significantly lower with SEVs, regardless of the definition used and adjustment for body mass index. Use of SEVs was associated with better quality of life outcomes as assessed by the Valve Academic Research Consortium-3 ordinal quality of life measure. Conclusions and Relevance Among women with severe symptomatic aortic stenosis and small aortic annuli undergoing transcatheter aortic valve replacement, the use of SEVs, compared to BEVs, resulted in similar clinical outcomes and a markedly reduced incidence of bioprosthetic valve dysfunction through 12 months, including a lower risk of prosthesis-patient mismatch and better 12-month quality of life. Trial Registration ClinicalTrials.gov Identifier: NCT04722250
Transcatheter Mitral Valve Replacement After Surgical Repair or Replacement
Background: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. Methods: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. Results: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76–996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510–1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR ( P <0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients ( P =0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P <0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P =0.02). The rates of Mitral Valve Academic Research Consortium–defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P =0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74–12.56; P =0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88–21.53; P <0.001) were both independently associated with repeat mitral valve replacement. Conclusions: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.
Mortality prediction after transcatheter treatment of failed bioprosthetic aortic valves utilizing various international scoring systems: Insights from the Valve‐in‐Valve International Data (VIVID)
Abstract Background Transcatheter Aortic Valve Implantation (TAVI) is commonly used to deploy new bioprosthetic valves inside degenerated surgically implanted aortic valves in high risk patients. The three scoring systems used to assess risk of postprocedural mortality are: Logistic EuroSCORE (LES), EuroSCORE II (ES II), and Society of Thoracic Surgeons (STS). Objective The purpose of this study is to analyze the accuracy of LES, ES II, and STS in estimating all‐cause mortality after transcatheter aortic valve‐in‐valve (ViV) implantations, which was not assessed before. Methods Using the Valve‐in‐Valve International Data (VIVID) registry, a total of 1,550 patients from 110 centers were included. The study compared the observed 30‐day overall mortality vs. the respective predicted mortalities calculated by risk scores. The accuracy of prediction models was assessed based on calibration and discrimination. Results Observed mortality at 30 days was 5.3%, while average expected mortalities by LES, ES II and STS were 29.49 (± 17.2), 14.59 (± 8.6), and 9.61 (± 8.51), respectively. All three risk scores overestimated 30‐day mortality with ratios of 0.176 (95% CI 0.138–0.214), 0.342 (95% CI 0.264–0.419), and 0.536 (95% CI 0.421–0.651), respectively. 30‐day mortality ROC curves demonstrated that ES II had the largest AUC at 0.722, followed by STS at 0.704, and LES at 0.698. Conclusions All three scores overestimated mortality at 30 days with ES II showing the highest predictability compared to LES and STS; and therefore, should be recommended for ViV procedures. There is a need for a dedicated scoring system for patients undergoing ViV interventions.