Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Clinical Predictors of Mortality in Prehospital Distress Calls by Emergency Medical Service Subscribers
(1) Introduction: Most studies rely on in-hospital data to predict cardiovascular risk and do not include prehospital information that is substantially important for early decision making. The aim of the study was to define clinical parameters in the prehospital setting, which may affect clinical outcomes. (2) Methods: In this population-based study, we performed a retrospective analysis of emergency calls that were made by patients to the largest private emergency medical services (EMS) in Israel, SHL Telemedicine Ltd., who were treated on-site by the EMS team. Demographics, clinical characteristics, and clinical outcomes were analyzed. Mortality was evaluated at three time points: 1, 3, and 12 months’ follow-up. The first EMS prehospital measurements of the systolic blood pressure (SBP) were recorded and analyzed. Logistic regression analyses were performed. (3) Results: A total of 64,320 emergency calls were included with a follow-up of 12 months post index EMS call. Fifty-five percent of patients were men and the mean age was 70.2 ± 13.1 years. During follow-up of 12 months, 7.6% of patients died. Age above 80 years (OR 3.34; 95% CI 3.03–3.69, p < 0.005), first EMS SBP ≤ 130 mm Hg (OR 2.61; 95% CI 2.36–2.88, p < 0.005), dyspnea at presentation (OR 2.55; 95% CI 2.29–2.83, p < 0001), and chest pain with ischemic ECG changes (OR 1.95; 95% CI 1.71–2.23, p < 0.001) were the highest predictors of 1 month mortality and remained so for mortality at 3 and 12 months. In contrast, history of hypertension and first EMS prehospital SBP ≥ 160 mm Hg were significantly associated with decreased mortality at 1, 3 and 12 months. (4) Conclusions: We identified risk predictors for all-cause mortality in a large cohort of patients during prehospital EMS calls. Age over 80 years, first EMS-documented prehospital SBP < 130 mm Hg, and dyspnea at presentation were the most profound risk predictors for short- and long-term mortality. The current study demonstrates that in prehospital EMS call settings, several parameters can be used to improve prioritization and management of high-risk patients.
Transcatheter Mitral Valve Replacement After Surgical Repair or Replacement
Background: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. Methods: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. Results: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76–996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510–1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR ( P <0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients ( P =0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P <0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P =0.02). The rates of Mitral Valve Academic Research Consortium–defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P =0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74–12.56; P =0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88–21.53; P <0.001) were both independently associated with repeat mitral valve replacement. Conclusions: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.
Mortality prediction after transcatheter treatment of failed bioprosthetic aortic valves utilizing various international scoring systems: Insights from the Valve‐in‐Valve International Data (VIVID)
Abstract Background Transcatheter Aortic Valve Implantation (TAVI) is commonly used to deploy new bioprosthetic valves inside degenerated surgically implanted aortic valves in high risk patients. The three scoring systems used to assess risk of postprocedural mortality are: Logistic EuroSCORE (LES), EuroSCORE II (ES II), and Society of Thoracic Surgeons (STS). Objective The purpose of this study is to analyze the accuracy of LES, ES II, and STS in estimating all‐cause mortality after transcatheter aortic valve‐in‐valve (ViV) implantations, which was not assessed before. Methods Using the Valve‐in‐Valve International Data (VIVID) registry, a total of 1,550 patients from 110 centers were included. The study compared the observed 30‐day overall mortality vs. the respective predicted mortalities calculated by risk scores. The accuracy of prediction models was assessed based on calibration and discrimination. Results Observed mortality at 30 days was 5.3%, while average expected mortalities by LES, ES II and STS were 29.49 (± 17.2), 14.59 (± 8.6), and 9.61 (± 8.51), respectively. All three risk scores overestimated 30‐day mortality with ratios of 0.176 (95% CI 0.138–0.214), 0.342 (95% CI 0.264–0.419), and 0.536 (95% CI 0.421–0.651), respectively. 30‐day mortality ROC curves demonstrated that ES II had the largest AUC at 0.722, followed by STS at 0.704, and LES at 0.698. Conclusions All three scores overestimated mortality at 30 days with ES II showing the highest predictability compared to LES and STS; and therefore, should be recommended for ViV procedures. There is a need for a dedicated scoring system for patients undergoing ViV interventions.
Standardized Definition of Structural Valve Degeneration for Surgical and Transcatheter Bioprosthetic Aortic Valves
Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.