Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Thirty-Day Outcomes of Transcatheter Mitral Valve Replacement for Degenerated Mitral Bioprostheses (Valve-in-Valve), Failed Surgical Rings (Valve-in-Ring), and Native Valve With Severe Mitral Annular Calcification (Valve-in-Mitral Annular Calcification) in
Background: Transcatheter mitral valve replacement using aortic transcatheter heart valves has recently become an alternative for patients with degenerated mitral bioprostheses, failed surgical repairs with annuloplasty rings or severe mitral annular calcification who are poor surgical candidates. Outcomes of these procedures are collected in the Society of Thoracic Surgeons/American College of Cardiology/Transcatheter Valve Therapy Registry. A comprehensive analysis of mitral valve-in-valve (MViV), mitral valve-in-ring (MViR), and valve-in-mitral annular calcification (ViMAC) outcomes has not been performed. We sought to evaluate short-term outcomes of early experience with MViV, MViR, and ViMAC in the United States. Methods: Retrospective analysis of data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Results: Nine hundred three high-risk patients (median Society of Thoracic Surgeons score 10%) underwent MViV (n=680), MViR (n=123), or ViMAC (n=100) between March 2013 and June 2017 at 172 hospitals. Median age was 75 years, 59.2% female. Technical and procedural success were higher in MViV. Left ventricular outflow tract obstruction occurred more frequently with ViMAC (ViMAC=10%, MViR=4.9%, MViV=0.7%; P <0.001). In-hospital mortality (MViV=6.3%, MViR=9%, ViMAC=18%; P =0.004) and 30-day mortality (MViV=8.1%, MViR=11.5%, ViMAC=21.8%; P =0.003) were higher in ViMAC. At 30-day follow-up, median mean mitral valve gradient was 7 mm Hg, most patients (96.7%) had mitral regurgitation grade ≤1 (+) and were in New York Heart Association class I to II (81.7%). Conclusions: MViV using aortic balloon-expandable transcatheter heart valves is associated with a low complication rate, a 30-day mortality lower than predicted by the Society of Thoracic Surgeons score, and superior short-term outcomes than MViR and ViMAC. At 30 days, patients in all groups experienced improvement of symptoms, and valve performance remained stable. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02245763.