Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Outcomes of Transcatheter Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Disease
Background: Patients with bicuspid aortic valve (AV) stenosis were excluded from the pivotal evaluations of transcatheter AV replacement (TAVR) devices. We sought to evaluate the outcomes of TAVR in patients with bicuspid AV stenosis in comparison with those with tricuspid AV stenosis. Methods: We used data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry (November 2011 through November 2018) to determine device success, procedural outcomes, post-TAVR valve performance, and in-hospital clinical outcomes (mortality, stroke, and major bleeding) according to valve morphology (bicuspid versus tricuspid). Results were stratified by older and current (Sapien 3 and Evolut R) generation valve prostheses. Medicare administrative claims were used to evaluate mortality and stroke to 1 year among eligible individuals (≥65 years). Results: After exclusions, there were 170 959 eligible procedures at 593 sites during the specified interval. Of these, 5412 TAVR procedures (3.2%) were performed in patients with bicuspid AV, including 3705 with current-generation devices. In comparison with patients with tricuspid valves, patients with bicuspid AV were younger and had a lower Society of Thoracic Surgeons Predicted Risk of Operative Mortality score. When current-generation devices were used to treat patients with bicuspid AV, device success increased (93.5 versus 96.3; P =0.001) and the incidence of 2+ aortic insufficiency declined (14.0% versus 2.7%; P <0.001) in comparison with older-generation devices. With current-generation devices, device success was slightly lower in the bicuspid (versus tricuspid) AV group (96.3% in bicuspid versus 97.4% in tricuspid, P =0.07), with a slightly higher incidence of residual moderate or severe aortic insufficiency among patients with bicuspid AV (2.7% versus 2.1%; P <0.001). A lower 1-year adjusted risk of mortality (hazard ratio, 0.88 [95% CI, 0.78–0.99]) was observed for patients with bicuspid AV versus patients with tricuspid AV in the Medicare-linked cohort, whereas no difference was observed in the 1-year adjusted risk of stroke (hazard ratio, 1.14 [95% CI, 0.94–1.39]). Conclusions: Using current-generation devices, procedural, postprocedural, and 1-year outcomes were comparable following TAVR for bicuspid AV versus tricuspid AV disease. With newer-generation devices, TAVR is a viable treatment option for patients with bicuspid AV disease.