Evaluation of a Liquid Biopsy-Breast Cancer Methylation (LBx-BCM) Cartridge Assay for Predicting Early Disease Progression and Survival: TBCRC 005 Prospective Trial
Abstract Purpose: We previously demonstrated that high levels of circulating methylated DNA are associated with subsequent disease progression in women with metastatic breast cancer (MBC). In this study, we evaluated the clinical utility of a novel liquid biopsy-breast cancer methylation (LBx-BCM) prototype assay using the GeneXpert cartridge system for early assessment of disease progression in MBC. Experimental Design: The 9-marker LBx-BCM prototype assay was evaluated in TBCRC 005, a prospective biomarker study, using plasma collected at baseline, week 4, and week 8 from 144 patients with MBC. Results: At week 4, patients with MBC with high cumulative methylation (CM) had a significantly shorter median PFS (2.88 months vs. 6.60 months, P = 0.001) and OS (14.52 months vs. 22.44 months, P = 0.005) compared with those with low CM. In a multivariable model, high versus low CM was also associated with shorter PFS (HR, 1.90; 95% CI, 1.20–3.01; P = 0.006). Change in CM from baseline to week 4 (OR, 4.60; 95% CI, 1.77–11.93; P = 0.002) and high levels of CM at week 4 (OR, 2.78; 95% CI, 1.29–5.99; P = 0.009) were associated with progressive disease at the time of first restaging. A robust risk model based on week 4 circulating CM levels was developed to predict disease progression as early as 3 months after initiating a new treatment. Conclusions: The automated LBx-BCM prototype assay is a promising clinical tool for detecting disease progression a month after initiating treatment in women with MBC undergoing routine care. The next step is to validate its clinical utility for specific treatments.
Self-expanding Transcatheter vs Surgical Aortic Valve Replacement in Intermediate-Risk Patients
Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.