Prospective Observational Study of Pain Severity and Pain Interference Outcomes Following Percutaneous MRI-guided Laser Ablation or Cryoablation for Focal Painful Peripheral, Soft Tissue Vascular Malformations: 12-month Outcomes
Background: Percutaneous image-guided thermal ablation has emerged as a treatment option for vascular malformations (VM). However, prospective data on intermediate to long-term effectiveness with uniform follow-up are lacking. Purpose: To prospectively evaluate the 12-month pain severity and pain interference outcomes following percutaneous MRI-guided laser ablation and cryoablation of focal painful, peripheral soft tissue VM. Materials and Methods: Participants undergoing clinically indicated MRI-guided laser ablation and cryoablation for focal painful (worst pain ≥4 out of 10 on Visual Analog Scale), peripheral soft tissue vascular malformations (VM) were enrolled in an IRB-approved prospective, observational study after giving informed consent. Participants completed the Brief Pain Inventory questionnaire prior to ablation and 1, 3, 6, and 12-month postablation. Differences in pain severity and interference outcomes from baseline on a 0 to 10 scale were compared using a paired t-test. Results: Seventeen participants (15 female; mean age 28.3 ± 9.3 years) underwent 24 MRI-guided and monitored ablation sessions including laser (n = 21), cryoablation (n = 2), or both (n = 1) for treatment of painful slow-flow (n = 16) or high-flow (n = 1) VM. Median maximal VM diameter was 5.7 cm (range 1.1 to 31.0 cm). Mean (±SD) preablation worst pain score was 7.9 ± 1.4. There was a significant decrease in worst pain at 1-month postablation (–3.5 ± 2.9; P = .0007) that was sustained at 3 (–3.4 ± 3.2; P = .0007), 6 (–4.2 ± 3.6; P = .0003), and 12 months (–3.6 ± 3.9; P = .002), with similar results for average, current, and least pain scores. There was a significant improvement in pain interference outcomes at 12-month postablation: general activity (P = .018), walking ability (P = .008), work (P = .003), sleep (P = .007), and enjoyment of life (P = .033). Conclusions: These data suggest that MRI-guided and monitored thermal ablation is safe and provides early and sustained significant improvements in pain severity and pain interference outcomes during the first year of follow-up in participants with focal painful peripheral soft tissue VM.
Self-expanding Transcatheter vs Surgical Aortic Valve Replacement in Intermediate-Risk Patients
Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.