First-in-Human Safety and Feasibility of Nodal and Pedal MR Lymphangiography with Gadopiclenol
Thompson, Scott M. , Collins, Jeremy D. , Bendel, Emily C. , Reisenauer, Christopher J., Jundt, Michael C., Yalҫin, Müge, Favazza, Christopher , Lu, Aiming , McDonald, Robert J. , Williamson, Eric E. , Stinson, Eric G. , In, MyungHo, Favazza, Christopher P , Messina, Steven A , Collins, Jeremy , Williamson, Eric , Thompson, Scott , Bendel, Emily , In, Myung-Ho , Jundt, Michael C., In, Myung‐Ho , Messina, Steven A.

Radiology: Cardiothoracic Imaging | July 2, 2026 | Volume: 8 | Issue: 4 | Pages: No page available

10.1148/ryct.260067 Get It

Dynamic gadopiclenol-enhanced nodal and pedal MR lymphangiography was safe, with no adverse events, and feasible for imaging peripheral and central conducting lymphatic anatomy.
Interventional High Monoenergetic Spectral CT for Percutaneous Thermal Ablation Procedures
Parvinian, Ahmad , Huber, Nathan R. , Musa, Juna , Ferrero, Andrea , Welch, Brian T. , Favazza, Christopher , Hibbert, Rebecca , Adamo, Daniel A. , Favazza, Christopher P, Huber, Nathan Robert

Journal of Computer Assisted Tomography | September 16, 2025 | Volume: 50 | Issue: 1 | Pages: 113-117

10.1097/rct.0000000000001786 Get It

Objective: The purpose of this study was to evaluate the potential clinical value of spectral CT for image guidance during percutaneous thermal ablation, particularly investigating high monoenergetic (MonoE) for metal artifact reduction. Materials and Methods: A phantom experiment was performed in which an ablation probe was scanned in “continuous CT” (CCT) mode on a spectral CT scanner. ROI measurements quantified metal artifacts for conventional and MonoE CCT images. Subsequently, a retrospective reader study was conducted with 10 patient cases. Three radiologists reviewed cases to select the optimal MonoE setting and perform a Likert score rating (+2: MonoE preferred, −2: conventional preferred). Results: Phantom measurements indicated a reduction in metal artifact for high MonoE (150 keV: −46 HU) relative to conventional CCT (−122 HU). The MonoE setting preference was 151±21 keV. The mean Likert score was 1.2±0.7. Radiologists indicated a perceived benefit of high MonoE CCT when probe placement was near a critical structure. Conclusions: This study indicates a clinical preference for high MonoE CCT compared with conventional CCT. Insofar as spectral CCT can be offered at a clinically feasible time frame, our results support the assessment of 150 keV image to reduce metal artifact while maintaining satisfactory soft tissue contrast.
Mucinous Appendiceal Neoplasms and Pseudomyxoma Peritonei: Imaging Features and Current Therapies
Jorgenson, Laura C. , Wang, Sherry S. , Navin, Patrick J. , Favazza, Christopher , Venkatesh, Sudhakar K. , Fidler, Jeff L. , Fletcher, Joel G. , Ehman, Eric C. , Sheedy, Shannon P. , Navin, Patrick , Venkatesh, Sudhakar K , Fidler, Jeff L. , Fletcher, Joel G , Grotz, Travis E. , Graham, Rondell P.

RadioGraphics | May 29, 2025 | Volume: 45 | Issue: 6 | Pages: No page available

10.1148/rg.240131 Get It

Radiologists are integral members of the interdisciplinary team for patients with mucinous appendiceal neoplasms and can directly affect care by suggesting the diagnosis of pseudomyxoma peritonei, optimizing imaging protocols for evaluating peritoneal implants, and reporting the primary tumor and spilled tumor cells thoroughly.
Photon Counting Detector CTA for Prostate Artery Embolization Pre-Procedure Planning and Intra-Procedural Guidance: A Case Series
Yousif, Paul , Linch, Forrest , Favazza, Christopher , Ferrero, Andrea , Jundt, Michael C., Linch, Forrest B , Yousif, Paul, Rajiah, Prabhakar , Collins, Jeremy D. , Thompson, Scott M.

No container title available | February 4, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-5898895/v1 Get It

Abstract Background: Prostate artery embolization (PAE) requires a careful understanding of pelvic arterial anatomy and identifying prostatic artery variants. Pre-procedure CTA and intra-procedural cone beam CT are traditional means of planning and performing PAE, with the latter providing guidance for embolization. Photon counting detector (PCD) CT is a novel technology enabling ultra-high spatial resolution (UHR) whole-body imaging, with reconstructed slices as thin as 200 um. For PAE, we obtain a single UHR PCD CT acquisition, which provides both detailed pre-procedure pelvic arterial anatomy information and a registration reference for intra-procedural embolization guidance. Case Presentation: In five patients who underwent technically successful PAE via a left transradial approach, the pre-procedure diagnostic UHR PCD prostate CTA delineated bilateral prostatic artery origins and course in all cases, as confirmed with conventional angiograms. Further, registration of the UHR PCD CT for embolization guidance was successful in all cases, augmenting vessel selection. No complication occurred. Conclusion: UHR PCD CT is a novel acquisition option that is well suited to PAE due to its ability to delineate small vessels. Further, our experience has shown that a single pre-procedure scan can also be utilized for intra-procedural embolization guidance, obviating the need for a traditional cone beam CT angiogram. Further research is needed to assess reductions in radiation dose, contrast use, and intra-procedural time with these techniques.
Novel Use of Motor-Evoked Potential Monitoring During Magnetic Resonance Imaging-Guided Soft-Tissue Cryoablation: A Case Report
Forcrand, Claire de, Oishi, Tatsuya , Woodrum, David A. , Lu, Aiming , Favazza, Chris P., Hoffman, E. Matthew , Pasternak, Jeffrey J., Powell, Garret M. , Teixeira, Miguel T. , Hoffman, Ernest M., Thompson, Scott M. , Adamo, Daniel A. , Favazza, Christopher

A&A Practice | August 6, 2024 | Volume: 18 | Issue: 8 | Pages: e01832

10.1213/xaa.0000000000001832 Get It

Motor-evoked potential (MEP) monitoring is an electrophysiologic technique useful for testing peripheral motor nerve integrity during cryoablation cases with risk of nerve injury. Previously, neuromonitoring within the magnetic resonance imaging (MRI) suite for cryoablation has not been performed as magnetic needles are used which could cause magnetic field interactions with neuromonitoring leads. We present the first report of a patient who underwent MEP monitoring during MRI-guided cryoablation of a vascular malformation adjacent to the brachial plexus. We demonstrate that MEPs may be safely and accurately performed by interleaving MRI and MEPs during treatment, reducing the risk of postprocedural complications.
Thermometry mapping during CT-guided thermal ablations: proof of feasibility and internal validation using spectral CT
Zhang, Kuan , Ferrero, Andrea , In, Myung‐Ho , Favazza, Christopher , Favazza, Christopher P, In, Myung-Ho

Physics in Medicine & Biology | April 30, 2024 | Volume: 69 | Issue: 11 | Pages: 115022

10.1088/1361-6560/ad45a3 Get It

Abstract Objective . Conventional computed tomography (CT) imaging does not provide quantitative information on local thermal changes during percutaneous ablative therapy of cancerous and benign tumors, aside from few qualitative, visual cues. In this study, we have investigated changes in CT signal across a wide range of temperatures and two physical phases for two different tissue mimicking materials, each. Approach . A series of experiments were conducted using an anthropomorphic phantom filled with water-based gel and olive oil, respectively. Multiple, clinically used ablation devices were applied to locally cool or heat the phantom material and were arranged in a configuration that produced thermal changes in regions with inconsequential amounts of metal artifact. Eight fiber optic thermal sensors were positioned in the region absent of metal artifact and were used to record local temperatures throughout the experiments. A spectral CT scanner was used to periodically acquire and generate electron density weighted images. Average electron density weighted values in 1 mm 3 volumes of interest near the temperature sensors were computed and these data were then used to calculate thermal volumetric expansion coefficients for each material and phase. Main results . The experimentally determined expansion coefficients well-matched existing published values and variations with temperature—maximally differing by 5% of the known value. As a proof of concept, a CT-generated temperature map was produced during a heating time point of the water-based gel phantom, demonstrating the capability to map changes in electron density weighted signal to temperature. Significance . This study has demonstrated that spectral CT can be used to estimate local temperature changes for different materials and phases across temperature ranges produced by thermal ablations.
Deep convolutional‐neural‐network‐based metal artifact reduction for CT‐guided interventional oncology procedures (MARIO)
Cao, Wenchao , Parvinian, Ahmad , Welch, Brian T. , Callstrom, Matthew R. , Ren, Liqiang , Missert, A. , Favazza, Christopher , Adamo, Daniel, Welch, Brian, Callstrom, Matthew, Missert, Andrew, Favazza, Christopher P, Adamo, Daniel A. , Missert, Andrew

Medical Physics | February 14, 2024 | Volume: 51 | Issue: 6 | Pages: 4231-4242

10.1002/mp.16980 Get It

AbstractBackgroundComputed tomography (CT) is routinely used to guide cryoablation procedures. Notably, CT‐guidance provides 3D localization of cryoprobes and can be used to delineate frozen tissue during ablation. However, metal‐induced artifacts from ablation probes can make accurate probe placement challenging and degrade the ice ball conspicuity, which in combination could lead to undertreatment of potentially curable lesions.PurposeIn this work, we propose an image‐based neural network (CNN) model for metal artifact reduction for CT‐guided interventional procedures.MethodsAn image domain metal artifact simulation framework was developed and validated for deep‐learning‐based metal artifact reduction for interventional oncology (MARIO). CT scans were acquired for 19 different cryoablation probe configurations. The probe configurations varied in the number of probes and the relative orientations. A combination of intensity thresholding and masking based on maximum intensity projections (MIPs) was used to segment both the probes only and probes + artifact in each phantom image. Each of the probe and probe + artifact images were then inserted into 19 unique patient exams, in the image domain, to simulate metal artifact appearance for CT‐guided interventional oncology procedures. The resulting 361 pairs of simulated image volumes were partitioned into disjoint training and test datasets of 304 and 57 volumes, respectively. From the training partition, 116 600 image patches with a shape of 128 × 128 × 5 pixels were randomly extracted to be used for training data. The input images consisted of a superposition of the patient and probe + artifact images. The target images consisted of a superposition of the patient and probe only images. This dataset was used to optimize a U‐Net type model. The trained model was then applied to 50 independent, previously unseen CT images obtained during renal cryoablations. Three board‐certified radiologists with experience in CT‐guided ablations performed a blinded review of the MARIO images. A total of 100 images (50 original, 50 MARIO processed) were assessed across different aspects of image quality on a 4‐point likert‐type item. Statistical analyses were performed using Wilcoxon signed‐rank test for paired samples.ResultsReader scores were significantly higher for MARIO processed images compared to the original images across all metrics (all p < 0.001). The average scores of the overall image quality, iceball conspicuity, overall metal artifact, needle tip visualization, target region confidence, and worst metal artifact, needle tip visualization, iceball conspicuity, and target region confidence improved by 34.91%, 36.29%, 39.94%, 34.17%, 35.13%, and 45.70%, respectively.ConclusionsThe proposed method of image‐based metal artifact simulation can be used to train a MARIO algorithm to effectively reduce probe‐related metal artifacts in CT‐guided cryoablation procedures.
Adaptation of a channelized Hotelling observer model to accommodate anthropomorphic backgrounds and moving test objects in X‐ray angiography
Gomez‐Cardona, Daniel, Favazza, Christopher , Schueler, Beth A. , Fetterly, Kenneth A. , Favazza, Christopher P, Leng, Shuai

Medical Physics | September 15, 2023 | Volume: 50 | Issue: 11 | Pages: 6737-6747

10.1002/mp.16686 Get It

AbstractBackgroundPrior implementations of the channelized Hotelling observer (CHO) model have succeeded in assessing the performance of X‐ray angiography systems under a variety of imaging conditions. However, often times these conditions do not resemble those present in routine clinical imaging scenarios, such as having complex anthropomorphic backgrounds in conjunction with moving test objects.PurposeThis work builds up on prior established CHO methods and introduces a new approach to switch from the already established “multiple‐sample” CHO implementation to a “single‐sample” technique. The proposed implementation enables the inclusion of moving test objects upon nonuniform backgrounds by allowing only a single sample to represent the test object present condition that is to be used within the statistical test to estimate the detectability index.MethodsTo assess the proposed method, two image data sets were acquired with a clinical X‐ray angiography system. The first set consisted of a uniform background in combination with static test objects while the second consisted of an anthropomorphic chest phantom in conjunction with moving test objects. The first set was used to validate the proposed approach against the multiple‐sample method while the second was used to assess the feasibility of the proposed method under a variety of imaging conditions, including seven object sizes and seven detector target dose (DTD) levels.ResultsFor the uniform background data set, considering all detectability indices greater or equal than 1, the ratio between the detectability indices of the proposed single‐sample approach versus the multiple‐sample method was 0.997 ± 0.056 (range 0.884–1.159). The average single‐direction width of the 95% confidence intervals (CIs) of the detectability index estimates for the multiple‐sample method was 0.38 ± 0.43 (range 0.03–2.20). For the single‐sample approach, the average width was 2.52 ± 0.63 (range 1.11–5.44). For the anthropomorphic background image set, the results were consistent with classical quantum‐limited signal‐to‐noise ratio (SNR) theory. The magnitude of the detectability indices varied predictably with changes in both object size and DTD, with the highest value associated with the highest dose and the largest object size. Additionally, the proposed method was able to capture differences in the imaging performance for a given test object across the field of view, which was associated with the attenuation levels provided by different features of the anthropomorphic background.ConclusionsA new single‐sample variant of the CHO model to assess the performance of X‐ray angiography imaging systems is proposed. The new approach is consistent with quantum‐limited image quality theory and with a standard implementation of the CHO model. The proposed method enables the assessment of moving test objects in combination with complex, nonuniform image backgrounds, thereby opening the possibility to assess imaging conditions which more closely resemble those used in clinical care.
Establishing a quality assurance program for photon counting detector (PCD) CT: Tips and caveats
Ahmed, Zaki , Ferrero, Andrea , Ren, Liqiang , Vrieze, Thomas J., Favazza, Christopher , Yu, Lifeng , Bruesewitz, Michael R. , Favazza, Christopher P, Rajendran, Kishore , Yu, Lifeng , McCollough, Cynthia H. , Leng, Shuai

Journal of Applied Clinical Medical Physics | June 19, 2023 | Volume: 24 | Issue: 7 | Pages: No page available

10.1002/acm2.14074 Get It

AbstractPurposeTo determine the suitability of a quality assurance (QA) program based on the American College of Radiology's (ACR) CT quality control (QC) manual to fully evaluate the unique capabilities of a clinical photon‐counting‐detector (PCD) CT system.MethodsA daily QA program was established to evaluate CT number accuracy and artifacts for both standard and ultra‐high‐resolution (UHR) scan modes. A complete system performance evaluation was conducted in accordance with the ACR CT QC manual by scanning the CT Accreditation Phantom with routine clinical protocols and reconstructing low‐energy‐threshold (T3D) and virtual monoenergetic images (VMIs) between 40 and 120 keV. Spatial resolution was evaluated by computing the modulation transfer function (MTF) for the UHR mode, and multi‐energy performance was evaluated by scanning a body phantom containing four iodine inserts with concentrations between 2 and 15 mg I/cc.ResultsThe daily QA program identified instances when the detector needed recalibration or replacement. CT number accuracy was impacted by image type: CT numbers at 70 keV VMI were within the acceptable range (defined for 120 kV). Other keV VMIs and the T3D reconstruction had at least one insert with CT number outside the acceptable range. The limiting resolution was nearly 40 lp/cm based on MTF measurements, which far exceeds the 12 lp/cm maximum capability of the ACR phantom. The CT numbers in the iodine inserts were accurate on all VMIs (3.8% average percentage error), while the iodine concentrations had an average root mean squared error of 0.3 mg I/cc.ConclusionProtocols and parameters must be properly selected on PCD‐CT to meet current accreditation requirements with the ACR CT phantom. Use of the 70 keV VMI allowed passing all tests prescribed in the ACR CT manual. Additional evaluations such an MTF measurement and multi‐energy phantom scans are also recommended to comprehensively evaluate PCD‐CT scanner performance.
Prospective Observational Study of Pain Severity and Pain Interference Outcomes Following Percutaneous MRI-guided Laser Ablation or Cryoablation for Focal Painful Peripheral, Soft Tissue Vascular Malformations: 12-month Outcomes
Koepsel, Erica M. Knavel , Powell, Garret M. , Bendel, Emily C. , Howe-Clayton, Desirae L., Favazza, Christopher , Lu, Aiming , Anderson, Katelyn , Tollefson, Megha M. , Woodrum, David A. , Thompson, Scott M. , Bjarnason, Haraldur , Polites, Stephanie F. , Adamo, Daniel A.

Journal of Vascular Anomalies | January 4, 2023 | Volume: 4 | Issue: 1 | Pages: e055

10.1097/jova.0000000000000055 Get It

Background: Percutaneous image-guided thermal ablation has emerged as a treatment option for vascular malformations (VM). However, prospective data on intermediate to long-term effectiveness with uniform follow-up are lacking. Purpose: To prospectively evaluate the 12-month pain severity and pain interference outcomes following percutaneous MRI-guided laser ablation and cryoablation of focal painful, peripheral soft tissue VM. Materials and Methods: Participants undergoing clinically indicated MRI-guided laser ablation and cryoablation for focal painful (worst pain ≥4 out of 10 on Visual Analog Scale), peripheral soft tissue vascular malformations (VM) were enrolled in an IRB-approved prospective, observational study after giving informed consent. Participants completed the Brief Pain Inventory questionnaire prior to ablation and 1, 3, 6, and 12-month postablation. Differences in pain severity and interference outcomes from baseline on a 0 to 10 scale were compared using a paired t-test. Results: Seventeen participants (15 female; mean age 28.3 ± 9.3 years) underwent 24 MRI-guided and monitored ablation sessions including laser (n = 21), cryoablation (n = 2), or both (n = 1) for treatment of painful slow-flow (n = 16) or high-flow (n = 1) VM. Median maximal VM diameter was 5.7 cm (range 1.1 to 31.0 cm). Mean (±SD) preablation worst pain score was 7.9 ± 1.4. There was a significant decrease in worst pain at 1-month postablation (–3.5 ± 2.9; P = .0007) that was sustained at 3 (–3.4 ± 3.2; P = .0007), 6 (–4.2 ± 3.6; P = .0003), and 12 months (–3.6 ± 3.9; P = .002), with similar results for average, current, and least pain scores. There was a significant improvement in pain interference outcomes at 12-month postablation: general activity (P = .018), walking ability (P = .008), work (P = .003), sleep (P = .007), and enjoyment of life (P = .033). Conclusions: These data suggest that MRI-guided and monitored thermal ablation is safe and provides early and sustained significant improvements in pain severity and pain interference outcomes during the first year of follow-up in participants with focal painful peripheral soft tissue VM.