Back to Authors

Vrieze, Thomas J.

Mayo Clinic

Mayo Clinic

Citations 9

Establishing a quality assurance program for photon counting detector (PCD) CT: Tips and caveats
Ahmed, Zaki , Ferrero, Andrea , Ren, Liqiang , Vrieze, Thomas J., Favazza, Christopher , Yu, Lifeng , Bruesewitz, Michael R. , Favazza, Christopher P, Rajendran, Kishore , Yu, Lifeng , McCollough, Cynthia H. , Leng, Shuai

Journal of Applied Clinical Medical Physics | June 19, 2023 | Volume: 24 | Issue: 7 | Pages: No page available

10.1002/acm2.14074 Get It

AbstractPurposeTo determine the suitability of a quality assurance (QA) program based on the American College of Radiology's (ACR) CT quality control (QC) manual to fully evaluate the unique capabilities of a clinical photon‐counting‐detector (PCD) CT system.MethodsA daily QA program was established to evaluate CT number accuracy and artifacts for both standard and ultra‐high‐resolution (UHR) scan modes. A complete system performance evaluation was conducted in accordance with the ACR CT QC manual by scanning the CT Accreditation Phantom with routine clinical protocols and reconstructing low‐energy‐threshold (T3D) and virtual monoenergetic images (VMIs) between 40 and 120 keV. Spatial resolution was evaluated by computing the modulation transfer function (MTF) for the UHR mode, and multi‐energy performance was evaluated by scanning a body phantom containing four iodine inserts with concentrations between 2 and 15 mg I/cc.ResultsThe daily QA program identified instances when the detector needed recalibration or replacement. CT number accuracy was impacted by image type: CT numbers at 70 keV VMI were within the acceptable range (defined for 120 kV). Other keV VMIs and the T3D reconstruction had at least one insert with CT number outside the acceptable range. The limiting resolution was nearly 40 lp/cm based on MTF measurements, which far exceeds the 12 lp/cm maximum capability of the ACR phantom. The CT numbers in the iodine inserts were accurate on all VMIs (3.8% average percentage error), while the iodine concentrations had an average root mean squared error of 0.3 mg I/cc.ConclusionProtocols and parameters must be properly selected on PCD‐CT to meet current accreditation requirements with the ACR CT phantom. Use of the 70 keV VMI allowed passing all tests prescribed in the ACR CT manual. Additional evaluations such an MTF measurement and multi‐energy phantom scans are also recommended to comprehensively evaluate PCD‐CT scanner performance.
Dependence of Water-equivalent Diameter and Size-specific Dose Estimates on CT Tube Potential
McCollough, Cynthia H. , McCollough, Shannon , Schneider, Justine J. , Moen, Taylor R., Weaver, Jayse , Vrieze, Thomas J., Yu, Lifeng , Leng, Shuai , McCollough, Shannon L , Weaver, Jayse M , McCollough, Cynthia H , Leng, Shuai , Yu, Lifeng

Radiology | January 18, 2022 | Volume: 303 | Issue: 2 | Pages: 404-411

10.1148/radiol.210860 Get It

Basal Ganglia Calcification Is Associated With Local and Systemic Metabolic Mechanisms in Adult Hypoparathyroidism
Zavatta, Guido , Tebben, Peter J. , McCollough, Cynthia H. , Yu, Lifeng , Vrieze, Thomas J., Clarke, B.L. , Vrieze, Thomas, Clarke, Bart L , McCollough, Cynthia H , Tebben, Peter , Yu, Lifeng

The Journal of Clinical Endocrinology & Metabolism | March 31, 2021 | Volume: 106 | Issue: 7 | Pages: 1900-1917

10.1210/clinem/dgab162 Get It

Abstract Context Hypoparathyroidism is characterized by low serum calcium, increased serum phosphorus, and inappropriately low or decreased serum parathyroid hormone, which may be associated with soft tissue calcification in the basal ganglia of the brain. Objective To assess the prevalence and factors involved in the pathophysiology of basal ganglia calcification (BGC) in the brain in chronic hypoparathyroidism and to evaluate proposed pathophysiologic mechanisms. Design Case-control study with retrospective review of medical records over 20 years. Setting Single academic medical center. Patients 142 patients with chronic hypoparathyroidism and computed tomography (CT) head scans followed between January 1, 2000 and July 9, 2020, and 426 age- and sex-matched controls with CT head scans over the same interval. Interventions None. Main Outcome Measures Demographic, biochemical, and CT head imaging findings, with semiquantitative assessment of volumetric BGC. Results The study found that 25.4% of 142 patients followed for a median of 17 years after diagnosis of chronic hypoparathyroidism had BGC, which developed at a younger age than in controls. BGC was 5.1-fold more common in nonsurgical patients and less common in postsurgical patients. Low serum calcium and low calcium/phosphate ratio correlated with BGC. Neither serum phosphorus nor calcium × phosphate product predicted BGC. Lower serum calcium was associated with greater volume of BGC. The extent of BGC varied widely, with nonsurgical patients generally having a greater volume and distribution of calcification. Conclusions BGC is associated with low serum calcium and low serum calcium/phosphate ratio, which may be related to severity of the disease, its etiology, or duration of treatment.
Technical Note: Increased photon starvation artifacts at low helical pitch in ultra‐low‐dose CT
Browne, Jacinta E. , Bruesewitz, Michael R. , Vrieze, Thomas J., Yu, Lifeng , Browne, Jacinta , McCollough, Cynthia H. , Yu, Lifeng

Medical Physics | October 3, 2019 | Volume: 46 | Issue: 12 | Pages: 5538-5543

10.1002/mp.13845 Get It

PurposeThe aim of this study was to demonstrate that a low helical pitch causes increased photon starvation artifacts at ultra‐low‐dose CT.MethodsA cylindrical water phantom with a diameter of 30 cm was scanned on two different generation CT scanners: a 64‐slice scanner (Sensation 64, Siemens Healthcare) and a 192‐slice scanner (Somatom Force, Siemens Healthcare) at multiple effective mAs levels (mAs/pitch = 200, 100, 50, 25, and 12). The corresponding CTDIvol values were 4.1, 2.0, 1.0, 0.5 mGy, on the 64‐slice scanner and 3.8, 1.9, 1.0, 0.5 mGy on the 192‐slice scanner, for the selected effective mAs values. For each dose setting, the scan was repeated at four helical pitches: 1.2, 0.9, 0.6, and the lowest achievable pitch on each scanner. The tube current was automatically adjusted by the scanner so that the effective mAs, and thus CTDIvol, were kept the same for different pitches. All CT data sets were reconstructed with a slice thickness of 3mm and a medium smooth kernel. Images acquired at the same dose level but different helical pitches were visually inspected to assess photon starvation artifacts and noise levels.ResultsAt the same radiation dose, image noise increased with the decreasing helical pitch. The increase was more severe on the old‐generation 64‐slice scanner. Photon starvation artifacts were evident at 200 effective mAs on the 64‐slice scanner at 80 kV. On the 192‐slice scanner there was no visible photon starvation artifacts at both 200 and 50 effective mAs (CTDIvol = 4.1 mGy and 1.0 mGy, respectively); nor was there a visible impact from the lower helical pitch. Only when the dose was lowered to be extremely low (~0.26 mGy, achievable at 70 kV), did photon starvation artifacts become evident.ConclusionsA low helical pitch may increase image noise and photon starvation artifacts compared to a higher pitch for the same dose level, particularly at ultra‐low dose CT.
Lead Shielding in Pediatric Chest CT: Effect of Apron Placement Outside the Scan Volume on Radiation Dose Reduction
Yu, Lifeng , Bruesewitz, Michael R. , Vrieze, Thomas J., Yu, Lifeng , McCollough, Cynthia H.

American Journal of Roentgenology | November 13, 2018 | Volume: 212 | Issue: 1 | Pages: 151-156

10.2214/ajr.17.19405 Get It

Implementation and evaluation of a protocol management system for automated review of CT protocols
Grimes, Joshua, Vrieze, Thomas J., McCollough, C, Leng, Shuai , Zhang, Yi

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 17 | Issue: 5 | Pages: 523-533

10.1120/jacmp.v17i5.6164 Get It

Protocol review is important to decrease the risk of patient injury and increase the consistency of CT image quality. A large volume of CT protocols makes manual review labor‐intensive, error‐prone, and costly. To address these challenges, we have developed a software system for automatically managing and monitoring CT protocols on a frequent basis. This article describes our experiences in the implementation and evaluation of this protocol monitoring system. In particular, we discuss various strategies for addressing each of the steps in our protocol‐monitoring workflow, which are: maintaining an accurate set of master protocols, retrieving protocols from the scanners, comparing scanner protocols to master protocols, reviewing flagged differences between the scanner and master protocols, and updating the scanner and/or master protocols. In our initial evaluation focusing only on abdomen and pelvis protocols, we detected 309 modified protocols in a 24‐week trial period. About one‐quarter of these modified protocols were determined to contain inappropriate (i.e., erroneous) protocol parameter modifications that needed to be corrected on the scanner. The most frequently affected parameter was the series description, which was inappropriately modified 47 times. Two inappropriate modifications were made to the tube current, which is particularly important to flag as this parameter impacts both radiation dose and image quality. The CT protocol changes detected in this work provide strong motivation for the use of an automated CT protocol quality control system to ensure protocol accuracy and consistency.PACS number(s): 87.57.Q‐
Construction of realistic phantoms from patient images and a commercial three-dimensional printer
Chen, Baiyu , Vrieze, Thomas J., Kuhlmann, Joel, Yu, Lifeng , Alexander, Amy E. , Matsumoto, Jane M., Vrieze, Thomas, Alexander, Amy, Matsumoto, Jane, Leng, Shuai , Yu, Lifeng , Morris, Jonathan M. , McCollough, Cynthia H. , McCollough, Cynthia H , Leng, Shuai , Morris, Jonathan

Journal of Medical Imaging | July 8, 2016 | Volume: 3 | Issue: 3 | Pages: 033501

10.1117/1.jmi.3.3.033501 Get It

Radiation Dose Levels for Interventional CT Procedures
Christner, Jodie A., Carlson, Stephanie K., Jacobsen, Megan C. , Vrieze, Thomas J., Atwell, Thomas D. , Leng, Shuai , McCollough, Cynthia H.

American Journal of Roentgenology | July 1, 2011 | Volume: 197 | Issue: 1 | Pages: W97-W103

10.2214/ajr.10.5057 Get It

Dose and Image Quality Evaluation of a Dedicated Cone-Beam CT System for High-Contrast Neurologic Applications
Yu, Lifeng , Vrieze, Thomas J., Bruesewitz, Michael R. , Kofler, James M., DeLone, David R. , Pallanch, John F., Lindell, E. Paul , Yu, Lifeng , McCollough, Cynthia H.

American Journal of Roentgenology | January 21, 2010 | Volume: 194 | Issue: 2 | Pages: W193-W201

10.2214/ajr.09.2951 Get It