Back to Authors

Ahmed, Zaki

https://orcid.org/0000-0001-5648-0590

Mayo Clinic

Mayo Clinic

Citations 5

Performance evaluation of single‐ and dual‐contrast spectral imaging on a photon‐counting‐detector CT
Ren, Liqiang , Zhou, Zhongxing , Ahmed, Zaki , Yu, Lifeng , Rajendran, Kishore , Fletcher, Joel G. , McCollough, Cynthia H. , Yu, Lifeng

Medical Physics | September 5, 2024 | Volume: 51 | Issue: 11 | Pages: 8034-8046

10.1002/mp.17367 Get It

AbstractBackgroundThe first commercially available photon‐counting‐detector CT (PCD‐CT) has been introduced for clinical use. However, its spectral performance on single‐ and dual‐contrast imaging tasks has not been comprehensively assessed.PurposeTo evaluate the spectral imaging performance of a clinical PCD‐CT system for single‐contrast material [iodine (I) or gadolinium (Gd)] and dual‐contrast materials (I and Gd) in comparison with a dual‐source dual‐energy CT (DS‐DECT).MethodsIodine (5, 10, and 15 mg/mL) and gadolinium (3.3, 6.6, and 9.9 mg/mL) samples, and their mixtures (I/Gd: 5/3.3 and 10/6.6 mg/mL) were prepared and placed in two torso‐shaped water phantoms (lateral dimensions: 30 and 40 cm). These phantoms were scanned on a PCD‐CT (NAEOTOM Alpha, Siemens) at 90, 120, and 140 kV. The same phantoms were scanned on a DS‐DECT (SOMATOM Force, Siemens) with 70/Sn150, 80/Sn150, 90/Sn150, and 100/Sn150 kV. The radiation dose levels were matched [volume CT dose index (CTDIvol): 10 mGy for the 30 cm phantom and 20 mGy for the 40 cm phantom] across all tube voltage settings and between scanners. Two‐material decomposition (I/water or Gd/water) was performed on iodine or gadolinium samples, and three‐material decomposition (I/Gd/water) on both individual samples and mixtures. On each decomposed image, mean mass concentration (± standard deviation) was measured in circular region‐of‐interests placed on the contrast samples. Root‐mean‐square‐error (RMSE) values of iodine and gadolinium concentrations were reported based on the measurements across all contrast samples and repeated on 10 consecutive slices.ResultsFor all material decomposition tasks on the DS‐DECT, the kV pairs with greater spectral separation (70/Sn150 kV and 80/Sn150 kV) yielded lower RMSE values than other DS‐DECT and PCD‐CT alternatives. Specifically, for the optimal 70/Sn150 kV, RMSE values were 1.2 ± 0.1 mg/mL (I) for I/water material decomposition, 1.0 ± 0.1 mg/mL (Gd) for Gd/water material decomposition, and 4.5 ± 0.2 mg/mL (I) and 3.7 ± 0.2 mg/mL (Gd), respectively, for I/Gd/water material decomposition. On the PCD‐CT, the optimal tube voltages were 120 or 140 kV for I/water decomposition with RMSE values of 2.0 ± 0.1 mg/mL (I). For Gd/water decomposition on PCD‐CT, the optimal tube voltage was 140 kV with gadolinium RMSE values of 1.5 ± 0.1 mg/mL (Gd), with the 90 kV setting on PCD‐CT generating higher RMSE values for gadolinium concentration compared to all DS‐DECT and PCD‐CT alternatives. For three material decomposition, both imaging modalities demonstrated substantially higher RMSE values for iodine and gadolinium, with 90 kV being the optimal tube potential for Gd/I quantitation on PCD‐CT [5.4 ± 0.3 mg/mL (I) and 3.9 ± 0.2 mg/mL (Gd)], and DS‐DECT at 100/Sn150 kV having larger RMSE values for both materials compared to the alternatives for either modality.ConclusionOptimal tube voltage for material decomposition on the clinical PCD‐CT is task‐dependent but inferior to DS‐DECT using 70/Sn150 kV or 80/Sn150 kV in two‐material decomposition for single‐contrast imaging (iodine/water or gadolinium/water). Three material decomposition (iodine/gadolinium/water) in dual‐contrast imaging yields substantially higher RMSE for both imaging platforms.
The ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast‐Enhanced challenge
Shalom, Eve , Kim, Harrison , Heijden, Rianne A. van der , Ahmed, Zaki , Patel, Reyna, DiCarlo, Julie C. , Yankeelov, Thomas E. , Stokes, Ashley M. , Grech‐Sollars, Matthew , Sahoo, Prativa , Verma, Sanjay Kumar , Rathore, Divya, Kazerouni, Anum S. , LoCastro, Eve , Paudyal, Ramesh , Wolansky, Ivan A. , Shukla‐Dave, Amita , Schouten, Pepijn, Gurney‐Champion, Oliver J. , Macíček, Ondřej , Vitouš, Jiří , Das, Ayesha , Mikheev, Artem , Rusinek, Henry , Cristinacce, Penny L. Hubbard , Little, Ross A. , Cheung, Susan , O’Connor, James P.B. , Moloney, Brendan, Bobholz, Samuel , Duenweg, Savannah , Laue, Hendrik , Sung, Kyunghyun , Nabavizadeh, Ali , Rad, Hamidreza Saligheh , Hu, Leland , Kazerooni, Anahita Fathi , Shalom, Eve S , van der Heijden, Rianne A , Hormuth, David A , DiCarlo, Julie C , Yankeelov, Thomas E , Dortch, Richard D , Grech-Sollars, Matthew , Kazerouni, Anum S , Partridge, Savannah C , LoCastro, Eve , Wolansky, Ivan A , Jiřík, Radovan , Macíček, Ondřej , Bartoš, Michal , Vitouš, Jiří , Das, Ayesha Bharadwaj , Kim, S Gene , Rusinek, Henry , Berks, Michael , Hubbard Cristinacce, Penny L , O'Connor, James P B , Parker, Geoff J M , LaViolette, Peter S , Bobholz, Samuel , Duenweg, Savannah , Virostko, John , Sung, Kyunghyun , Saligheh Rad, Hamidreza , Sourbron, Steven , Bell, Laura C , Fathi Kazerooni, Anahita , Paudyal, Ramesh , Shukla-Dave, Amita , Sisco, Nicholas J. , Inglese, Marianna , Toschi, Nicola , Singh, Anup K. , Schouten, Pepijn, Bokacheva, Louisa , Bell, Laura C.

Magnetic Resonance in Medicine | December 20, 2023 | Volume: 91 | Issue: 5 | Pages: 1803-1821

10.1002/mrm.29909 Get It

AbstractPurpose has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast‐Enhanced (OSIPI‐DCE) challenge was designed to benchmark methods to better help the efforts to standardize measurement.MethodsA framework was created to evaluate values produced by DCE‐MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' values, the applied software, and a standard operating procedure. These were evaluated using the proposed score defined with accuracy, repeatability, and reproducibility components.ResultsAcross the 10 received submissions, the score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility.ConclusionsThis study reports results from the OSIPI‐DCE challenge and highlights the high inter‐software variability within estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real‐world clinical setting, many of these tools may perform differently with different benchmarking methodology.
Locally Low-Rank Denoising of Multi-Echo Functional MRI Data With Application in Resting-State Analysis
Meyer, Nolan , Ahmed, Zaki , In, Myung‐Ho , Shu, Yunhong , Trzasko, Joshua D. , Meyer, Nolan K , In, Myung-Ho , Kang, Daehun , Huston, John , Bernstein, Matt A.

Topics in Magnetic Resonance Imaging | October 5, 2023 | Volume: 32 | Issue: 5 | Pages: 37-49

10.1097/rmr.0000000000000307 Get It

Abstract: Objectives: Locally low-rank (LLR) denoising of functional magnetic resonance imaging (fMRI) time series image data is extended to multi-echo (ME) data. The proposed method extends the capabilities of non-physiologic noise suppression beyond single-echo applications with a dedicated ME algorithm. Materials and Methods: Following an institutional review board (IRB) approved protocol, resting-state fMRI data were acquired in 7 healthy subjects. A compact 3T scanner enabled whole-brain acquisition of multiband ME fMRI data at high spatial resolution (1.4 × 1.4 × 2.8 mm3) with a 1810 ms repetition time (TR). Image data were denoised with ME-LLR preceding functional processing. The results of connectivity maps generated from denoised data were compared with maps generated with equivalent processing of non-denoised images. To assess ME-LLR as a method to reduce scan time, comparisons were made between maps computed from image data with full and retrospectively truncated durations. Assessments were completed with seed-based connectivity analyses using echo-combined image data. In a feasibility assessment, nondenoised and denoised full-duration echo-combined data were equivalently processed with independent component analysis (ICA) and compared. Results: ME-LLR denoising yielded strengthened resting-state network connectivity maps after nuisance regression and seed-based connectivity analysis. In assessing ME-LLR as a scan reduction mechanism, maps generated from denoised data at half scan time showed comparable quality with maps generated from full-duration, non-denoised data, at both single subject and group levels. ME-LLR substantially increased temporal signal-to-noise ratio (tSNR) for image data respective to each individual echo and for image data after nuisance regression. Among echo-specific image volumes, increases in tSNR yielded by ME-LLR were most pronounced for image data with the longest echo time and thereby lowest SNR. ICA showed resting-state networks consistently identified between non-denoised and denoised data, with clearer demarcation of networks for ME-LLR. Conclusions: ME-LLR is demonstrated to suppress non-physiologic noise, enhance functional connectivity map quality, and could potentially facilitate scan time reduction in ME-fMRI.
Establishing a quality assurance program for photon counting detector (PCD) CT: Tips and caveats
Ahmed, Zaki , Ferrero, Andrea , Ren, Liqiang , Vrieze, Thomas J., Favazza, Christopher , Yu, Lifeng , Bruesewitz, Michael R. , Favazza, Christopher P, Rajendran, Kishore , Yu, Lifeng , McCollough, Cynthia H. , Leng, Shuai

Journal of Applied Clinical Medical Physics | June 19, 2023 | Volume: 24 | Issue: 7 | Pages: No page available

10.1002/acm2.14074 Get It

AbstractPurposeTo determine the suitability of a quality assurance (QA) program based on the American College of Radiology's (ACR) CT quality control (QC) manual to fully evaluate the unique capabilities of a clinical photon‐counting‐detector (PCD) CT system.MethodsA daily QA program was established to evaluate CT number accuracy and artifacts for both standard and ultra‐high‐resolution (UHR) scan modes. A complete system performance evaluation was conducted in accordance with the ACR CT QC manual by scanning the CT Accreditation Phantom with routine clinical protocols and reconstructing low‐energy‐threshold (T3D) and virtual monoenergetic images (VMIs) between 40 and 120 keV. Spatial resolution was evaluated by computing the modulation transfer function (MTF) for the UHR mode, and multi‐energy performance was evaluated by scanning a body phantom containing four iodine inserts with concentrations between 2 and 15 mg I/cc.ResultsThe daily QA program identified instances when the detector needed recalibration or replacement. CT number accuracy was impacted by image type: CT numbers at 70 keV VMI were within the acceptable range (defined for 120 kV). Other keV VMIs and the T3D reconstruction had at least one insert with CT number outside the acceptable range. The limiting resolution was nearly 40 lp/cm based on MTF measurements, which far exceeds the 12 lp/cm maximum capability of the ACR phantom. The CT numbers in the iodine inserts were accurate on all VMIs (3.8% average percentage error), while the iodine concentrations had an average root mean squared error of 0.3 mg I/cc.ConclusionProtocols and parameters must be properly selected on PCD‐CT to meet current accreditation requirements with the ACR CT phantom. Use of the 70 keV VMI allowed passing all tests prescribed in the ACR CT manual. Additional evaluations such an MTF measurement and multi‐energy phantom scans are also recommended to comprehensively evaluate PCD‐CT scanner performance.
Improved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients
Kang, Daehun , In, Myung‐Ho , Halverson, Maria, Meyer, Nolan , Ahmed, Zaki , Gray, Erin M. , Fernandez, Brice , Black, David F. , Welker, Kirk M. , Trzasko, Joshua D. , Huston, John , Shu, Yunhong , Huston, John , Halverson, Maria A, Meyer, Nolan K , Ahmed, Zaki , Fernandez, Brice , Shu, Yunhong , Kang, Daehun , In, Myung-Ho , Jo, Hang Joon , Madhavan, Radhika , Foo, Thomas , Bernstein, Matt A.

Sensors | April 28, 2023 | Volume: 23 | Issue: 9 | Pages: 4329

10.3390/s23094329 Get It

In blood-oxygen-level-dependent (BOLD)-based resting-state functional (RS-fMRI) studies, usage of multi-echo echo-planar-imaging (ME-EPI) is limited due to unacceptable late echo times when high spatial resolution is used. Equipped with high-performance gradients, the compact 3T MRI system (C3T) enables a three-echo whole-brain ME-EPI protocol with smaller than 2.5 mm isotropic voxel and shorter than 1 s repetition time, as required in landmark fMRI studies. The performance of the ME-EPI was comprehensively evaluated with signal variance reduction and region-of-interest-, seed- and independent-component-analysis-based functional connectivity analyses and compared with a counterpart of single-echo EPI with the shortest TR possible. Through the multi-echo combination, the thermal noise level is reduced. Functional connectivity, as well as signal intensity, are recovered in the medial orbital sulcus and anterior transverse collateral sulcus in ME-EPI. It is demonstrated that ME-EPI provides superior sensitivity and accuracy for detecting functional connectivity and/or brain networks in comparison with single-echo EPI. In conclusion, the high-performance gradient enabled high-spatial-temporal resolution ME-EPI would be the method of choice for RS-fMRI study on the C3T.