Back to Authors

Bell, Laura C

0000-0001-8164-8324

Mayo Clinic

Barrow Neurological Institute

Citations 3

The QIBA Profile for Dynamic Susceptibility Contrast MRI Quantitative Imaging Biomarkers for Assessing Gliomas
Shiroishi, Mark S. , Erickson, Bradley J. , Hu, Leland , Barboriak, Daniel P. , Becerra, Lino , Bell, Laura C. , Boss, Michael A. , Boxerman, Jerrold L. , Cen, Steven , Cimino, Lisa , Fan, Zhaoyang , Kirsch, John E. , Ameli, N. O. , Nazemi, Sina , Quarles, C. Chad , Rosen, Mark A. , Rodríguez, Luis Salvador, Zahlmann, Gudrun , Obuchowski, Nancy A. , Wu, Ona , Hu, Leland S., Chakhoyan, Ararat , Graaf, Wolter de, Dhakal, Kiran , Erickson, Bradley J., Kadbi, Mo , Quarles, Christopher Chad, Rodríguez, Luis G. , Rosen, Mark, Hu, Leland S , Keenan, Kathryn E , Kirsch, John E , Ameli, Nima , Nazemi, Sina , Quarles, C Chad , Rosen, Mark A , Rodriguez, Luis , Schmainda, Kathleen M , Zahlmann, Gudrun , Zhou, Yuxiang , Obuchowski, Nancy , Wu, Ona , Boxerman, Jerrold L , Boss, Michael A , Erickson, Bradley J , Barboriak, Daniel P , Bell, Laura C , Keenan, Kathryn E. , Zhou, Yuxiang , Hu, Leland S., Conte, Gian Marco , Ellingson, Benjamin M. , Emblem, Kyrre E , Erickson, Bradley J., Quarles, Christopher Chad

Radiology | December 10, 2024 | Volume: 313 | Issue: 3 | Pages: No page available

10.1148/radiol.232555 Get It

The Quantitative Imaging Biomarkers Alliance Profile for dynamic susceptibility contrast (DSC) MRI and its longitudinal claims for the precision of a DSC MRI–derived quantitative imaging biomarker to assess the relative cerebral blood volume changes in gliomas are summarized.
The ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast‐Enhanced challenge
Shalom, Eve , Kim, Harrison , Heijden, Rianne A. van der , Ahmed, Zaki , Patel, Reyna, DiCarlo, Julie C. , Yankeelov, Thomas E. , Stokes, Ashley M. , Grech‐Sollars, Matthew , Sahoo, Prativa , Verma, Sanjay Kumar , Rathore, Divya, Kazerouni, Anum S. , LoCastro, Eve , Paudyal, Ramesh , Wolansky, Ivan A. , Shukla‐Dave, Amita , Schouten, Pepijn, Gurney‐Champion, Oliver J. , Macíček, Ondřej , Vitouš, Jiří , Das, Ayesha , Mikheev, Artem , Rusinek, Henry , Cristinacce, Penny L. Hubbard , Little, Ross A. , Cheung, Susan , O’Connor, James P.B. , Moloney, Brendan, Bobholz, Samuel , Duenweg, Savannah , Laue, Hendrik , Sung, Kyunghyun , Nabavizadeh, Ali , Rad, Hamidreza Saligheh , Hu, Leland , Kazerooni, Anahita Fathi , Shalom, Eve S , van der Heijden, Rianne A , Hormuth, David A , DiCarlo, Julie C , Yankeelov, Thomas E , Dortch, Richard D , Grech-Sollars, Matthew , Kazerouni, Anum S , Partridge, Savannah C , LoCastro, Eve , Wolansky, Ivan A , Jiřík, Radovan , Macíček, Ondřej , Bartoš, Michal , Vitouš, Jiří , Das, Ayesha Bharadwaj , Kim, S Gene , Rusinek, Henry , Berks, Michael , Hubbard Cristinacce, Penny L , O'Connor, James P B , Parker, Geoff J M , LaViolette, Peter S , Bobholz, Samuel , Duenweg, Savannah , Virostko, John , Sung, Kyunghyun , Saligheh Rad, Hamidreza , Sourbron, Steven , Bell, Laura C , Fathi Kazerooni, Anahita , Paudyal, Ramesh , Shukla-Dave, Amita , Sisco, Nicholas J. , Inglese, Marianna , Toschi, Nicola , Singh, Anup K. , Schouten, Pepijn, Bokacheva, Louisa , Bell, Laura C.

Magnetic Resonance in Medicine | December 20, 2023 | Volume: 91 | Issue: 5 | Pages: 1803-1821

10.1002/mrm.29909 Get It

AbstractPurpose has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast‐Enhanced (OSIPI‐DCE) challenge was designed to benchmark methods to better help the efforts to standardize measurement.MethodsA framework was created to evaluate values produced by DCE‐MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' values, the applied software, and a standard operating procedure. These were evaluated using the proposed score defined with accuracy, repeatability, and reproducibility components.ResultsAcross the 10 received submissions, the score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility.ConclusionsThis study reports results from the OSIPI‐DCE challenge and highlights the high inter‐software variability within estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real‐world clinical setting, many of these tools may perform differently with different benchmarking methodology.
Evaluation of single bolus, dual-echo dynamic susceptibility contrast MRI protocols in brain tumor patients
Stokes, Ashley M. , Bergamino, Maurizio, Alhilali, Lea, Hu, Leland S, Karis, John P, Baxter, Leslie C, Bell, Laura C. , Quarles, C Chad, Bell, Laura C , Stokes, Ashley M , Bergamino, Maurizio, Alhilali, Lea, Hu, Leland S, Karis, John P, Baxter, Leslie C, Quarles, C Chad

Journal of Cerebral Blood Flow & Metabolism | August 20, 2021 | Volume: 41 | Issue: 12 | Pages: 3378-3390

10.1177/0271678x211039597 Get It

Relative cerebral blood volume (rCBV) obtained from dynamic susceptibility contrast (DSC) MRI is adversely impacted by contrast agent leakage in brain tumors. Using simulations, we previously demonstrated that multi-echo DSC-MRI protocols provide improvements in contrast agent dosing, pulse sequence flexibility, and rCBV accuracy. The purpose of this study is to assess the in-vivo performance of dual-echo acquisitions in patients with brain tumors (n = 59). To verify pulse sequence flexibility, four single-dose dual-echo acquisitions were tested with variations in contrast agent dose, flip angle, and repetition time, and the resulting dual-echo rCBV was compared to standard single-echo rCBV obtained with preload (double-dose). Dual-echo rCBV was comparable to standard double-dose single-echo protocols (mean (standard deviation) tumor rCBV 2.17 (1.28) vs. 2.06 (1.20), respectively). High rCBV similarity was observed (CCC = 0.96), which was maintained across both flip angle (CCC = 0.98) and repetition time (CCC = 0.96) permutations, demonstrating that dual-echo acquisitions provide flexibility in acquisition parameters. Furthermore, a single dual-echo acquisition was shown to enable quantification of both perfusion and permeability metrics. In conclusion, single-dose dual-echo acquisitions provide similar rCBV to standard double-dose single-echo acquisitions, suggesting contrast agent dose can be reduced while providing significant pulse sequence flexibility and complementary tumor perfusion and permeability metrics.