Back to Authors

Bell, Laura C.

https://orcid.org/0000-0001-8164-8324

Mayo Clinic

Duke University

Citations 6

The QIBA Profile for Dynamic Susceptibility Contrast MRI Quantitative Imaging Biomarkers for Assessing Gliomas
Shiroishi, Mark S. , Erickson, Bradley J. , Hu, Leland , Barboriak, Daniel P. , Becerra, Lino , Bell, Laura C. , Boss, Michael A. , Boxerman, Jerrold L. , Cen, Steven , Cimino, Lisa , Fan, Zhaoyang , Kirsch, John E. , Ameli, N. O. , Nazemi, Sina , Quarles, C. Chad , Rosen, Mark A. , Rodríguez, Luis Salvador, Zahlmann, Gudrun , Obuchowski, Nancy A. , Wu, Ona , Hu, Leland S., Chakhoyan, Ararat , Graaf, Wolter de, Dhakal, Kiran , Erickson, Bradley J., Kadbi, Mo , Quarles, Christopher Chad, Rodríguez, Luis G. , Rosen, Mark, Hu, Leland S , Keenan, Kathryn E , Kirsch, John E , Ameli, Nima , Nazemi, Sina , Quarles, C Chad , Rosen, Mark A , Rodriguez, Luis , Schmainda, Kathleen M , Zahlmann, Gudrun , Zhou, Yuxiang , Obuchowski, Nancy , Wu, Ona , Boxerman, Jerrold L , Boss, Michael A , Erickson, Bradley J , Barboriak, Daniel P , Bell, Laura C , Keenan, Kathryn E. , Zhou, Yuxiang , Hu, Leland S., Conte, Gian Marco , Ellingson, Benjamin M. , Emblem, Kyrre E , Erickson, Bradley J., Quarles, Christopher Chad

Radiology | December 10, 2024 | Volume: 313 | Issue: 3 | Pages: No page available

10.1148/radiol.232555 Get It

The Quantitative Imaging Biomarkers Alliance Profile for dynamic susceptibility contrast (DSC) MRI and its longitudinal claims for the precision of a DSC MRI–derived quantitative imaging biomarker to assess the relative cerebral blood volume changes in gliomas are summarized.
The ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast‐Enhanced challenge
Shalom, Eve , Kim, Harrison , Heijden, Rianne A. van der , Ahmed, Zaki , Patel, Reyna, DiCarlo, Julie C. , Yankeelov, Thomas E. , Stokes, Ashley M. , Grech‐Sollars, Matthew , Sahoo, Prativa , Verma, Sanjay Kumar , Rathore, Divya, Kazerouni, Anum S. , LoCastro, Eve , Paudyal, Ramesh , Wolansky, Ivan A. , Shukla‐Dave, Amita , Schouten, Pepijn, Gurney‐Champion, Oliver J. , Macíček, Ondřej , Vitouš, Jiří , Das, Ayesha , Mikheev, Artem , Rusinek, Henry , Cristinacce, Penny L. Hubbard , Little, Ross A. , Cheung, Susan , O’Connor, James P.B. , Moloney, Brendan, Bobholz, Samuel , Duenweg, Savannah , Laue, Hendrik , Sung, Kyunghyun , Nabavizadeh, Ali , Rad, Hamidreza Saligheh , Hu, Leland , Kazerooni, Anahita Fathi , Shalom, Eve S , van der Heijden, Rianne A , Hormuth, David A , DiCarlo, Julie C , Yankeelov, Thomas E , Dortch, Richard D , Grech-Sollars, Matthew , Kazerouni, Anum S , Partridge, Savannah C , LoCastro, Eve , Wolansky, Ivan A , Jiřík, Radovan , Macíček, Ondřej , Bartoš, Michal , Vitouš, Jiří , Das, Ayesha Bharadwaj , Kim, S Gene , Rusinek, Henry , Berks, Michael , Hubbard Cristinacce, Penny L , O'Connor, James P B , Parker, Geoff J M , LaViolette, Peter S , Bobholz, Samuel , Duenweg, Savannah , Virostko, John , Sung, Kyunghyun , Saligheh Rad, Hamidreza , Sourbron, Steven , Bell, Laura C , Fathi Kazerooni, Anahita , Paudyal, Ramesh , Shukla-Dave, Amita , Sisco, Nicholas J. , Inglese, Marianna , Toschi, Nicola , Singh, Anup K. , Schouten, Pepijn, Bokacheva, Louisa , Bell, Laura C.

Magnetic Resonance in Medicine | December 20, 2023 | Volume: 91 | Issue: 5 | Pages: 1803-1821

10.1002/mrm.29909 Get It

AbstractPurpose has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast‐Enhanced (OSIPI‐DCE) challenge was designed to benchmark methods to better help the efforts to standardize measurement.MethodsA framework was created to evaluate values produced by DCE‐MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' values, the applied software, and a standard operating procedure. These were evaluated using the proposed score defined with accuracy, repeatability, and reproducibility components.ResultsAcross the 10 received submissions, the score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility.ConclusionsThis study reports results from the OSIPI‐DCE challenge and highlights the high inter‐software variability within estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real‐world clinical setting, many of these tools may perform differently with different benchmarking methodology.
BIOM-51. IDENTIFICATION OF A LOW-FLIP ANGLE BASED CBV THRESHOLD FOR FRACTIONAL TUMOR BURDEN (FTB) MAPPING IN RECURRENT GLIOBLASTOMA
Anil, Aliya , Stokes, Ashley M. , Alhilali, Lea , Karis, John P. , Eschbacher, Jennifer , Hu, Leland , Quarles, C. Chad , Bell, Laura C. , Boxerman, Jerrold L. , Schmainda, Kathleen M

Neuro-Oncology | November 11, 2023 | Volume: 25 | Issue: Supplement_5 | Pages: v15-v16

10.1093/neuonc/noad179.0062 Get It

Abstract INTRODUCTION Differentiation of glioblastoma recurrence from post treatment radiation effects (PTRE) would improve patient management. Dynamic susceptibility contrast (DSC) MRI can be used to generate fractional tumor burden (FTB) maps, via application of regional cerebral blood volume (RCBV) thresholds, to spatially differentiate recurrence from PTRE. FTB maps derived from a DSC-MRI protocol that includes a contrast agent preload in addition to the bolus injection and a moderate-flip angle (MFA) been histologically validated. Recently, a single-dose, low-flip angle (LFA) protocol was shown to provide RCBV measurements consistent with the MFA protocol and has been recommended as a consensus protocol. This study aims to identify the RCBV thresholds for the single-dose, LFA protocol that generates FTB maps, concordant with those obtained from the reference double-dose, MFA protocol. METHODS Two sets of DSC-MRI data were collected sequentially from 52 patients using a single-dose, low-flip angle (30o) protocol and a double-dose, moderate flip angle (60o) protocol using TR = 1.5s and TE = 30ms. Standardized RCBV maps (sRCBV) were obtained and co-registered with the post-contrast T1-weighted images using the FDA-approved clinical software, IB Neuro™ and IB Delta Suite™, respectively. The ground truth MFA-based FTB maps were computed using multiple sRCBV thresholds (1.0 and 1.75). An ROC analysis was conducted to identify the optimal, voxel-wise LFA sRCBV thresholds to produce FTB maps that best match the reference maps. RESULTS/ CONCLUSIONS The ROC analysis identified a lower LFA threshold of 1.0 to accurately distinguish PTRE from tumor recurrence and an upper threshold of 1.55 to differentiate aggressive tumor regions. The single-dose, LFA protocol eliminates variations in the contrast agent incubation time between the preload and bolus injection. This study provides motivation for the use of the single-dose LFA protocol in the management of patients with glioblastoma and is a reliable method for distinguishing tumor from PTRE.
Evaluation of single bolus, dual-echo dynamic susceptibility contrast MRI protocols in brain tumor patients
Stokes, Ashley M. , Bergamino, Maurizio, Alhilali, Lea, Hu, Leland S, Karis, John P, Baxter, Leslie C, Bell, Laura C. , Quarles, C Chad, Bell, Laura C , Stokes, Ashley M , Bergamino, Maurizio, Alhilali, Lea, Hu, Leland S, Karis, John P, Baxter, Leslie C, Quarles, C Chad

Journal of Cerebral Blood Flow & Metabolism | August 20, 2021 | Volume: 41 | Issue: 12 | Pages: 3378-3390

10.1177/0271678x211039597 Get It

Relative cerebral blood volume (rCBV) obtained from dynamic susceptibility contrast (DSC) MRI is adversely impacted by contrast agent leakage in brain tumors. Using simulations, we previously demonstrated that multi-echo DSC-MRI protocols provide improvements in contrast agent dosing, pulse sequence flexibility, and rCBV accuracy. The purpose of this study is to assess the in-vivo performance of dual-echo acquisitions in patients with brain tumors (n = 59). To verify pulse sequence flexibility, four single-dose dual-echo acquisitions were tested with variations in contrast agent dose, flip angle, and repetition time, and the resulting dual-echo rCBV was compared to standard single-echo rCBV obtained with preload (double-dose). Dual-echo rCBV was comparable to standard double-dose single-echo protocols (mean (standard deviation) tumor rCBV 2.17 (1.28) vs. 2.06 (1.20), respectively). High rCBV similarity was observed (CCC = 0.96), which was maintained across both flip angle (CCC = 0.98) and repetition time (CCC = 0.96) permutations, demonstrating that dual-echo acquisitions provide flexibility in acquisition parameters. Furthermore, a single dual-echo acquisition was shown to enable quantification of both perfusion and permeability metrics. In conclusion, single-dose dual-echo acquisitions provide similar rCBV to standard double-dose single-echo acquisitions, suggesting contrast agent dose can be reduced while providing significant pulse sequence flexibility and complementary tumor perfusion and permeability metrics.
Development of a spiral spin‐ and gradient‐echo (spiral‐SAGE) approach for improved multi‐parametric dynamic contrast neuroimaging
Stokes, Ashley M. , Ragunathan, Sudarshan , Robison, Ryan K. , Fuentes, Alberto, Karis, John P. , Pipe, James G. , Quarles, C. Chad , Pipe, James G , Bell, Laura C.

Magnetic Resonance in Medicine | July 20, 2021 | Volume: 86 | Issue: 6 | Pages: 3082-3095

10.1002/mrm.28933 Get It

PurposeThe purpose of this study was to develop a spiral‐based combined spin‐ and gradient‐echo (spiral‐SAGE) method for simultaneous dynamic contrast‐enhanced (DCE‐MRI) and dynamic susceptibility contrast MRI (DSC‐MRI).MethodsUsing this sequence, we obtained gradient‐echo TEs of 1.69 and 26 ms, a SE TE of 87.72 ms, with a TR of 1663 ms. Using an iterative SENSE reconstruction followed by deblurring, spiral‐induced image artifacts were minimized. Healthy volunteer images are shown to demonstrate image quality using the optimized reconstruction, as well as for comparison with EPI‐based SAGE. A bioreactor phantom was used to compare dynamic‐contrast time courses with both spiral‐SAGE and EPI‐SAGE. A proof‐of‐concept cohort of patients with brain tumors shows the range of hemodynamic maps available using spiral‐SAGE.ResultsComparison of spiral‐SAGE images with conventional EPI‐SAGE images illustrates substantial reductions of image distortion and artifactual image intensity variations. Bioreactor phantom data show similar dynamic contrast time courses between standard EPI‐SAGE and spiral‐SAGE for the second and third echoes, whereas first‐echo data show improvements in quantifying T1 changes with shorter echo times. In a cohort of patients with brain tumors, spiral‐SAGE–based perfusion and permeability maps are shown with comparison with the standard single‐echo EPI perfusion map.ConclusionSpiral‐SAGE provides a substantial improvement for the assessment of perfusion and permeability by mitigating artifacts typically encountered with EPI and by providing a shorter echo time for improved characterization of permeability. Spiral‐SAGE enables quantification of perfusion, permeability, and vessel architectural parameters, as demonstrated in brain tumors.
NIMG-28. VALIDATION OF SINGLE-DOSE DSC-MRI PROTOCOLS FOR ROBUST PERFUSION ASSESSMENT IN BRAIN TUMORS
Quarles, C. Chad , Semmineh, Natenael , Fuentes, Alberto, Nespodzany, Ashley , Alhilai, Lea, Karis, John P. , Rand, Scott D. , Dardis, Chris, Braun, Kelly, Connelly, Jennifer , Hu, Leland , Boxerman, J. L., Stokes, Ashley M. , Bell, Laura C. , Prah, Melissa A. , Connelly, Jennifer , Zhou, Yuxiang , Schmainda, Kathleen M

Neuro-Oncology | November 11, 2019 | Volume: 21 | Issue: Supplement_6 | Pages: vi167-vi167

10.1093/neuonc/noz175.699 Get It

Abstract Dynamic susceptibility contrast (DSC) MRI measures of brain tumor cerebral blood volume (CBV) are able to predict grade, overall survival and response to treatment. Wide-spread acceptance of DSC-MRI has been challenged by the need to balance contrast agent dose and CBV accuracy. The goal of this study was to identify and validate single-dose, BTIP compliant, DSC-MRI protocols. Using a validated, patient-based DRO, we evaluated CBV accuracy across a range of acquisition parameters (field strength, TR, TE, flip angle, multi-echo acquisitions, dosing protocols) and post-processing steps. To validate the optimal protocols, we next collected DSC-MRI data following ASFNR’s recommended “double – dose” approach, where a single-dose preload (to minimize T1 effects) is given prior to a second bolus injection (for DSC-MRI data acquisition). The single-dose DSC-MRI data was collected during the preload bolus injection. Consistency of the derived CBV data, visual agreement and data characteristics (e.g. CNR) was statistically evaluated. When using a single-dose and routine single-echo pulse sequence, the DRO analysis found that a low flip angle (LFA = 30o) and 30ms TE provided the highest CBV accuracy (concordance correlation coefficient (CCC) = 0.92) and precision (coefficient of variation (CV) = 8.2%)). For comparison, the maximum accuracy found with the DRO utilizes a double-dose injection protocol and yielded a CCC of 0.98 and CV of 6.8%. Single-dose, multi-echo acquisitions provided higher accuracy than the LFA data and matched that found with the double-dose approach. In patients (data collection ongoing), the agreement between single-dose LFA (n > 40) or multi-echo (n > 40) based CBV values and the reference double-dose approach was very high (CCC > 0.94) and were statistically equivalent. Optimized single-dose DSC-MRI protocols provide highly accurate CBV data, use lower doses of contrast agent, and simplify scan procedures, indicating their potential for robust use in clinical practice and trials.