AbstractPurposePerfusion MRI reveals important tumor physiological and pathophysiologic information, making it a critical component in managing brain tumor patients. This study aimed to develop a dual‐echo 3D spiral technique with a single‐bolus scheme to simultaneously acquire both dynamic susceptibility contrast (DSC) and dynamic contrast‐enhanced (DCE) data and overcome the limitations of current EPI‐based techniques.MethodsA 3D spiral‐based technique with dual‐echo acquisition was implemented and optimized on a 3T MRI scanner with a spiral staircase trajectory and through‐plane SENSE acceleration for improved speed and image quality, in‐plane variable‐density undersampling combined with a sliding‐window acquisition and reconstruction approach for increased speed, and an advanced iterative deblurring algorithm. Four volunteers were scanned and compared with the standard of care (SOC) single‐echo EPI and a dual‐echo EPI technique. Two patients were scanned with the spiral technique during a preload bolus and compared with the SOC single‐echo EPI collected during the second bolus injection.ResultsVolunteer data demonstrated that the spiral technique achieved high image quality, reduced geometric artifacts, and high temporal SNR compared with both single‐echo and dual‐echo EPI. Patient perfusion data showed that the spiral acquisition achieved accurate DSC quantification comparable to SOC single‐echo dual‐dose EPI, with the additional DCE information.ConclusionA 3D dual‐echo spiral technique was developed to simultaneously acquire both DSC and DCE data in a single‐bolus injection with reduced contrast use. Preliminary volunteer and patient data demonstrated increased temporal SNR, reduced geometric artifacts, and accurate perfusion quantification, suggesting a competitive alternative to SOC‐EPI techniques for brain perfusion MRI.
Development of a spiral spin‐ and gradient‐echo (spiral‐SAGE) approach for improved multi‐parametric dynamic contrast neuroimaging
PurposeThe purpose of this study was to develop a spiral‐based combined spin‐ and gradient‐echo (spiral‐SAGE) method for simultaneous dynamic contrast‐enhanced (DCE‐MRI) and dynamic susceptibility contrast MRI (DSC‐MRI).MethodsUsing this sequence, we obtained gradient‐echo TEs of 1.69 and 26 ms, a SE TE of 87.72 ms, with a TR of 1663 ms. Using an iterative SENSE reconstruction followed by deblurring, spiral‐induced image artifacts were minimized. Healthy volunteer images are shown to demonstrate image quality using the optimized reconstruction, as well as for comparison with EPI‐based SAGE. A bioreactor phantom was used to compare dynamic‐contrast time courses with both spiral‐SAGE and EPI‐SAGE. A proof‐of‐concept cohort of patients with brain tumors shows the range of hemodynamic maps available using spiral‐SAGE.ResultsComparison of spiral‐SAGE images with conventional EPI‐SAGE images illustrates substantial reductions of image distortion and artifactual image intensity variations. Bioreactor phantom data show similar dynamic contrast time courses between standard EPI‐SAGE and spiral‐SAGE for the second and third echoes, whereas first‐echo data show improvements in quantifying T1 changes with shorter echo times. In a cohort of patients with brain tumors, spiral‐SAGE–based perfusion and permeability maps are shown with comparison with the standard single‐echo EPI perfusion map.ConclusionSpiral‐SAGE provides a substantial improvement for the assessment of perfusion and permeability by mitigating artifacts typically encountered with EPI and by providing a shorter echo time for improved characterization of permeability. Spiral‐SAGE enables quantification of perfusion, permeability, and vessel architectural parameters, as demonstrated in brain tumors.