PurposeThe purpose of this study was to develop a spiral‐based combined spin‐ and gradient‐echo (spiral‐SAGE) method for simultaneous dynamic contrast‐enhanced (DCE‐MRI) and dynamic susceptibility contrast MRI (DSC‐MRI).MethodsUsing this sequence, we obtained gradient‐echo TEs of 1.69 and 26 ms, a SE TE of 87.72 ms, with a TR of 1663 ms. Using an iterative SENSE reconstruction followed by deblurring, spiral‐induced image artifacts were minimized. Healthy volunteer images are shown to demonstrate image quality using the optimized reconstruction, as well as for comparison with EPI‐based SAGE. A bioreactor phantom was used to compare dynamic‐contrast time courses with both spiral‐SAGE and EPI‐SAGE. A proof‐of‐concept cohort of patients with brain tumors shows the range of hemodynamic maps available using spiral‐SAGE.ResultsComparison of spiral‐SAGE images with conventional EPI‐SAGE images illustrates substantial reductions of image distortion and artifactual image intensity variations. Bioreactor phantom data show similar dynamic contrast time courses between standard EPI‐SAGE and spiral‐SAGE for the second and third echoes, whereas first‐echo data show improvements in quantifying T1 changes with shorter echo times. In a cohort of patients with brain tumors, spiral‐SAGE–based perfusion and permeability maps are shown with comparison with the standard single‐echo EPI perfusion map.ConclusionSpiral‐SAGE provides a substantial improvement for the assessment of perfusion and permeability by mitigating artifacts typically encountered with EPI and by providing a shorter echo time for improved characterization of permeability. Spiral‐SAGE enables quantification of perfusion, permeability, and vessel architectural parameters, as demonstrated in brain tumors.
NIMG-28. VALIDATION OF SINGLE-DOSE DSC-MRI PROTOCOLS FOR ROBUST PERFUSION ASSESSMENT IN BRAIN TUMORS
Abstract Dynamic susceptibility contrast (DSC) MRI measures of brain tumor cerebral blood volume (CBV) are able to predict grade, overall survival and response to treatment. Wide-spread acceptance of DSC-MRI has been challenged by the need to balance contrast agent dose and CBV accuracy. The goal of this study was to identify and validate single-dose, BTIP compliant, DSC-MRI protocols. Using a validated, patient-based DRO, we evaluated CBV accuracy across a range of acquisition parameters (field strength, TR, TE, flip angle, multi-echo acquisitions, dosing protocols) and post-processing steps. To validate the optimal protocols, we next collected DSC-MRI data following ASFNR’s recommended “double – dose” approach, where a single-dose preload (to minimize T1 effects) is given prior to a second bolus injection (for DSC-MRI data acquisition). The single-dose DSC-MRI data was collected during the preload bolus injection. Consistency of the derived CBV data, visual agreement and data characteristics (e.g. CNR) was statistically evaluated. When using a single-dose and routine single-echo pulse sequence, the DRO analysis found that a low flip angle (LFA = 30o) and 30ms TE provided the highest CBV accuracy (concordance correlation coefficient (CCC) = 0.92) and precision (coefficient of variation (CV) = 8.2%)). For comparison, the maximum accuracy found with the DRO utilizes a double-dose injection protocol and yielded a CCC of 0.98 and CV of 6.8%. Single-dose, multi-echo acquisitions provided higher accuracy than the LFA data and matched that found with the double-dose approach. In patients (data collection ongoing), the agreement between single-dose LFA (n > 40) or multi-echo (n > 40) based CBV values and the reference double-dose approach was very high (CCC > 0.94) and were statistically equivalent. Optimized single-dose DSC-MRI protocols provide highly accurate CBV data, use lower doses of contrast agent, and simplify scan procedures, indicating their potential for robust use in clinical practice and trials.