Abstract Hypoxia constrains cerebral oxygen availability and challenges brain function and stability. Although hypoxia-responsive functional connectivity (HR-FC) reorganizes rapidly with declining arterial oxygen partial pressure, its relationship to local neurovascular activity remains unclear. We examined time-resolved amplitude of low-frequency fluctuations (ALFF) in blood-oxygenation-level dependent (BOLD) fMRI during graded acute hypoxia in healthy adults, performing a continuous cognitive test (Go/No-go task) with concurrent physiological monitoring. Dynamic ALFF and functional connectivity were estimated using a sliding-window approach and analyzed across large-scale brain networks defined by Schaefer’s 17-network parcellation. Severe hypoxia elicited temporally dissociated responses across modalities. Functional connectivity increased monotonically, whereas ALFF exhibited pronounced nonlinear modulation, including phase-dependent divergence across networks. During hypoxic decompensation, the default mode network (DefaultA) showed marked ALFF suppression, whereas a ventral secondary somatosensory-dominant network (SomMotB) exhibited preferential preservation despite similar engagement in HR-FC. Together, these findings indicate that network-level ALFF captures a distinct yet complementary layer of functional dynamics, with a temporal profile distinct from functional connectivity. Spontaneous BOLD dynamics during acute hypoxia reflect structured network-level modulation rather than a uniform suppression attributable solely to reduced oxygen availability. These findings support a conceptual framework of cerebral oxygen budgeting , in which metabolic constraints reshape functional dynamics across brain networks.
Relationship Between Degree of Stenosis and Time-to-Peak Delay in High Grade Asymptomatic Carotid Artery Disease
BACKGROUND: Cerebral hemodynamic impairment in patients with asymptomatic high-grade (>70%) internal carotid artery (ICA) stenosis is associated with risk of stroke and cognitive decline, but correlations between the degree of stenosis and hemodynamic impairment are derived from small case series. Using baseline data from 242 participants in the CREST-H study (Carotid Revascularization and Medical Management for Asymptomatic Carotid Stenosis–Hemodynamics), we hypothesized that the degree of stenosis in the ICA would correlate with time-to-peak (TTP) delay in ipsilateral cerebral blood flow using MR/CT perfusion scans, adjusting for demographic and cardiovascular risk variables. METHODS: From all participants, ICAs were insonated using a 7 to 10 MHz probe for peak systolic velocity (PSV) and end diastolic velocity. Dynamic contrast perfusion imaging was standardized across 61 CREST-H sites, using standard sequential T2*-weighted perfusion imaging. CT perfusion used standard clinical protocols. TTP delay was calculated in the ipsilateral versus contralateral hemispheres. In cross-sectional analysis, linear regression was used to model TTP delay as the outcome variable and PSV, end diastolic velocity, and PSV ICA/common carotid artery ratio on the index and nonindex side as primary predictor variables in 6 separate models, adjusting for covariates, followed by automated backward elimination model reduction. RESULTS: Among 392 CREST-H participants, the 242 with complete data for all variables were included in the regression analysis (age, 70±7.6; 62% M). End diastolic velocity on the index side correlated with TTP delay (β=0.003, P =0.005). PSV had a similar correlation but did not reach significance (β=0.001, P =0.099), nor did ICA/common carotid artery ratio (β=0.003, P =0.126). Nonindex side PSV, end diastolic velocity, and ICA/common carotid artery ratio showed no correlation with TTP delay ( P =0.268, P =0.495, P =0.380, respectively). Circle of Willis completeness did not correlate with TTP. CONCLUSIONS: In this large cohort of patients with high-grade asymptomatic carotid stenosis, higher end-diastolic flow velocities correlated with greater TTP delays, supporting a definition of hemodynamically significant stenosis. Our findings have implications for the management of asymptomatic carotid stenosis, which will be tested in the CREST-H study. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03121209.
Magnetic resonance elastography characterization of meningioma mechanical properties for improved neurosurgical planning and resection: a prospective cohort study
Background: Accurate characterization of tumor stiffness and adhesion is crucial when surgically resecting meningiomas. Currently, such determinations are difficult to ascertain through standard preoperative imaging diagnostics and clinical experience. Herein, we explored magnetic resonance elastography (MRE) as a means of assessing these parameters and thereby improving neurosurgical resections. Methods: This prospective study of 193 patients with meningiomas involved three distinct patient subsets (cohort 1, 88 [2017–2021]; cohort 2, 55 [2022–2023]; cohort 3, 50 [2023–2024]. We analyzed preoperatively obtained MRE data on meningioma stiffness (cohorts 1 and 2) and adhesion (cohort 2) for accuracy, while matching subjects with or without MRE studies (cohort 3, 1:1 ratio) to define the role of preoperative MRE in improving operative outcomes. Results: Areas under the curve (AUCs) for MRE in gauging meningioma stiffness and adhesion were 0.87 and 0.89, respectively. Both parameters significantly surpassed empiric predictions of stiffness and adhesion rendered by surgeons and radiologists, based on routine magnetic resonance imaging (MRI). MRE-determined stiffness measures independently correlated with prolonged resection duration, whereas MRE-assessed adhesion showed independent associations with increased blood loss, longer duration of tumor resection, and higher risk of pial injury. Ultimately, results based on cohort 3 demonstrated that MRE has great potential in this setting to improve neurosurgical procedures by significantly reducing intraoperative bleeding, resection duration, and risks of pial injury. Conclusion: MRE is a promising, noninvasive tool for accurately assessing meningioma stiffness and adhesion, standing to improve the precision and safety of needed surgical intervention.
Medical Management and Revascularization for Asymptomatic Carotid Stenosis
ABSTRACT Background Magnetic resonance elastography (MRE) has demonstrated potential in characterizing intracranial tumors, including glioblastoma. The influence of pathology on measurement consistency and interobserver agreement needs evaluation to promote MRE implementation as a quantitative biomarker. Purpose To assess repeatability and interobserver agreement of absolute and normalized magnitude of the complex shear modulus (| G *|), storage modulus ( G ′), and loss modulus ( G ″) in glioblastoma. Study Type Prospective. Population Thirteen adults (5 male, 8 female, mean age 66.23 years) with histopathologically confirmed glioblastoma. Field Strength/Sequence 3 T MRI, modified single‐shot spin‐echo echo‐planar imaging. Assessment Two same‐session MRE acquisitions were performed with patient repositioning. The solid tumor component was independently segmented by 2 observers on contrast‐enhanced T1‐weighted images co‐registered to MRE maps. Statistical Tests Repeatability was assessed using the repeatability coefficient, coefficient of variation, and Bland–Altman plots, and interobserver agreement by the intraclass correlation coefficient. The Wilcoxon signed‐rank test compared parameters and coefficients of variation between tumor‐normal‐appearing white matter and absolute and normalized measurements. Significance was set at 0.05. Results Tumor | G *| and G ′ showed repeatability coefficients of 0.07–0.08 kPa and 0.05 kPa, compared with 0.13 kPa (| G *|) and 0.15–0.16 kPa ( G ′) for normalized measurements. Coefficients of variation in tumor regions were 1.42% ± 1.12%–1.60% ± 1.41% for | G *| and 1.19% ± 0.96%–2.08% ± 2.22% for G ′, significantly lower than normalized values (4.82% ± 4.49%–4.21% ± 4.27% for | G *|; 5.12% ± 5.04%–5.45% ± 4.53% for G ′). Tumor | G *| and G ′ showed excellent interobserver agreement (intraclass correlation coefficients 0.97 and 0.95). Tumor G ″ demonstrated higher variability than | G *| and G ′ (coefficients of variation 8.58% ± 7.69%–7.51% ± 6.73%), with no significant difference between absolute and normalized measurements ( p = 0.14). Data Conclusion Tumor | G *| and G ′ are the most repeatable metrics in glioblastoma. Normalization reduces measurement repeatability due to normal‐appearing white matter variability. The small sample size ( n = 13) limits generalizability. Evidence Level 2. Technical Efficacy Stage 2.
3D magnetization‐prepared rapid gradient echo with a RF saturation band on a compact 3T scanner
Abstract Background Flow‐related ghost artifact from a 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) sequence results from unsaturated magnetization of incoming arterial flow. This is especially common on MR scanners equipped with smaller radiofrequency (RF) transmit coils. A high‐performance compact 3T (C3T) scanner features a smaller RF‐transmit coil (inner diameter 37 cm, length 40 cm), leading to a rapid fall‐off of the B1 field below the neck. This configuration results in more intense flow‐related ghost artifacts, especially in younger patients. Purpose The C3T scanner's smaller RF‐transmit coil provides RF field coverage over the brain region, causing bright in‐flow arterial signals and flow‐related artifacts in the conventional 3D‐MPRAGE scans. The purpose of this study is to suppress these artifacts by adding a RF saturation band (RFSB) pulses to the 3D‐MPRAGE sequence. Methods The RFSB was added to the 3D‐MPRAGE sequence as a preparation pulse option. To test the effectiveness, 37 subjects were scanned on the C3T under an IRB‐approved protocol using 3D‐MPRAGE with and without RFSB. Ten of those subjects underwent repeated scans with and without RFSB to evaluate test‐retest reliability. A consensus evaluation by two neuroradiologists was performed on all data to compare signal to noise ratio, image contrast, presence of artifacts, and diagnostic confidence. Quantitative analysis included calculating test‐retest differences by image subtraction and evaluating the variance in flow‐artifact‐induced image intensity between the scans with and without RFSB. Additionally, one subject was scanned on a whole‐body 3T scanner using a transmit/receive (T/R) head coil to demonstrate the method's applicability across different MRI platforms as a proof of concept. Results The Wilcoxon signed‐rank test of the neuroradiologist evaluations showed a significant reduction in artifacts and an improvement in diagnostic confidence in the posterior fossa region with and without RFSB ( p < 0.0001). Test–retest analysis showed that adding RFSB significantly reduced image intensity variability in the cerebellum, even among subjects without visible flow artifacts. The normalized difference decreased from 8.71% to 6.41% ( p = 0.0059), suggesting improved image reliability in regions prone to flow‐related artifacts. Additionally, similar findings were observed in scans on a whole‐body 3T with a T/R head coil, demonstrating the broader applicability of this method. Conclusion Incorporating RFSB into 3D‐MPRAGE scans effectively reduces flow‐related ghost artifact on the C3T scanner, improving image quality and diagnostic confidence. These findings suggest that the proposed method could be widely implemented across MRI systems utilizing a smaller RF‐transmit coil.
Evaluation of Brain Stiffness in Patients Undergoing Carotid Angioplasty and Stenting Using Magnetic Resonance Elastography
ABSTRACTBackgroundPercutaneous transluminal angioplasty and stenting (PTAS) in patients with carotid stenosis may have potential effects on brain parenchyma. However, current studies on parenchymal changes are scarce due to the need for advanced imaging modalities. Consequently, the alterations in brain parenchyma following PTAS remain an unsolved issue.PurposeTo investigate changes to the brain parenchyma using magnetic resonance elastography (MRE).Study TypeProspective.Population13 patients (6 women and 7 men; 39 MRI imaging sessions) with severe unilateral carotid stenosis patients indicated for PTAS were recruited between 2021 and 2024.Field Strength/SequenceNoncontrast MRI sequences including MRE (spin echo) were acquired using 3 T scanners.AssessmentAll patients underwent MRE before (preprocedural), within 24 h (early postprocedural) and 3 months after (delayed postprocedural) PTAS. Preprocedural and delayed postprocedural ultrasonographic peak systolic velocity (PSV) was recorded. MRE stiffness and damping ratio were evaluated via neural network inversion of the whole brain, in 14 gray matter (GM) and 12 white matter (WM) regions.Statistical TestsStiffness and damping ratio differences between each pair of MR sessions for each subject were identified by paired sample t tests. The correlations of stiffness and damping ratio with stenosis grade and ultrasonographic PSV dynamics were evaluated by Pearson correlation coefficients. The statistical significance was defined as p < 0.05.ResultsThe stiffness of lesion side insula, deep GM, and deep WM increased significantly from preprocedural to delayed postprocedural MRE. Increasing deep GM stiffness on the lesion side was positively correlated with the DSA stenosis grade significantly (r = 0.609). The lesion side insula stiffness increments were positively correlated with PSV decrements significantly (r = 0.664).Data ConclusionRegional brain stiffness increased 3 months after PTAS. Lesion side stiffness was positively correlated with stenosis grades in deep GM and PSV decrements in the insula.Evidence Level2.Technical EfficacyStage 2.
White matter stimulation with single electrical pulses modulates neuronal activity in visual cortex