Abstract White matter bundles play a crucial role in cognitive functions by rapidly transmitting information between brain regions. Inter-areal conduction guides the integration of information and conduction velocity is a fundamental parameter in theories and models of brain function. However, distributions of conduction velocity remain difficult to characterize in vivo in humans. In this work, we integrated diffusion magnetic resonance imaging (dMRI) tractography with intracranial electrical stimulation during clinical stereo-electroencephalography (sEEG) monitoring in 17 subjects to measure conduction velocity within four major white matter bundles. Our findings reveal that human brain conduction is characterized by high variability both within and between bundles, reflecting a predominance of slow connections alongside rare high-speed connections. Because conduction velocity in myelinated fibers follows an approximately linear relationship with axon diameter, we derive underlying axon diameter distributions and show that these estimates are comparable to previous post-mortem studies. These findings demonstrate a heavily skewed distribution of human neural conduction velocities and show that structural heterogeneity shapes the timing and integration of information in large-scale networks.
3D magnetization‐prepared rapid gradient echo with a RF saturation band on a compact 3T scanner
Abstract Background Flow‐related ghost artifact from a 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) sequence results from unsaturated magnetization of incoming arterial flow. This is especially common on MR scanners equipped with smaller radiofrequency (RF) transmit coils. A high‐performance compact 3T (C3T) scanner features a smaller RF‐transmit coil (inner diameter 37 cm, length 40 cm), leading to a rapid fall‐off of the B1 field below the neck. This configuration results in more intense flow‐related ghost artifacts, especially in younger patients. Purpose The C3T scanner's smaller RF‐transmit coil provides RF field coverage over the brain region, causing bright in‐flow arterial signals and flow‐related artifacts in the conventional 3D‐MPRAGE scans. The purpose of this study is to suppress these artifacts by adding a RF saturation band (RFSB) pulses to the 3D‐MPRAGE sequence. Methods The RFSB was added to the 3D‐MPRAGE sequence as a preparation pulse option. To test the effectiveness, 37 subjects were scanned on the C3T under an IRB‐approved protocol using 3D‐MPRAGE with and without RFSB. Ten of those subjects underwent repeated scans with and without RFSB to evaluate test‐retest reliability. A consensus evaluation by two neuroradiologists was performed on all data to compare signal to noise ratio, image contrast, presence of artifacts, and diagnostic confidence. Quantitative analysis included calculating test‐retest differences by image subtraction and evaluating the variance in flow‐artifact‐induced image intensity between the scans with and without RFSB. Additionally, one subject was scanned on a whole‐body 3T scanner using a transmit/receive (T/R) head coil to demonstrate the method's applicability across different MRI platforms as a proof of concept. Results The Wilcoxon signed‐rank test of the neuroradiologist evaluations showed a significant reduction in artifacts and an improvement in diagnostic confidence in the posterior fossa region with and without RFSB ( p < 0.0001). Test–retest analysis showed that adding RFSB significantly reduced image intensity variability in the cerebellum, even among subjects without visible flow artifacts. The normalized difference decreased from 8.71% to 6.41% ( p = 0.0059), suggesting improved image reliability in regions prone to flow‐related artifacts. Additionally, similar findings were observed in scans on a whole‐body 3T with a T/R head coil, demonstrating the broader applicability of this method. Conclusion Incorporating RFSB into 3D‐MPRAGE scans effectively reduces flow‐related ghost artifact on the C3T scanner, improving image quality and diagnostic confidence. These findings suggest that the proposed method could be widely implemented across MRI systems utilizing a smaller RF‐transmit coil.
Lightweight, compact, and high‐performance 3T MR system for imaging the brain and extremities
PurposeTo build and evaluate a small‐footprint, lightweight, high‐performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole‐body clinical 3T MRI scanners, while achieving substantial reductions in installation costs.MethodsA conduction‐cooled magnet was developed that uses less than 12 liters of liquid helium in a gas‐charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42‐cm inner‐diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet‐gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80‐mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1‐MVA gradient drivers.ResultsIn a comparison of anatomical imaging in 16 patients using T2‐weighted 3D fluid‐attenuated inversion recovery (FLAIR) between the compact 3T and whole‐body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80‐mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain.ConclusionsThe compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole‐body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.