Lightweight, compact, and high‐performance 3T MR system for imaging the brain and extremities
Foo, Thomas , Laskaris, E.T., Vermilyea, Mark, Xu, Minfeng , Thompson, Paul, Conte, Gene, Epps, Christopher Van, Immer, Christopher, Tan, Ek T. , Graziani, Dominic, Mathieu, Jean‐Baptise, Hardy, Christopher J., Schenck, John F., Fiveland, Eric, Stautner, Wolfgang , Ricci, Justin, Piel, Joseph E., Park, Keith, Hua, Yihe , Bai, Ye , Kagan, Alex, Stanley, David A. , Weavers, Paul T., Gray, Erin M. , Shu, Yunhong , Frick, Matthew A., Trzasko, Joshua D. , Foo, Thomas K F , Tan, Ek T , Gray, Erin, Trzasko, Joshua, Bernstein, Matt A , Thompson, Paul, Epps, Chris Van, Lee, Seung‐Kyun , Campeau, Norbert G. , Huston, John , Bernstein, Matt A.

Magnetic Resonance in Medicine | March 15, 2018 | Volume: 80 | Issue: 5 | Pages: 2232-2245

10.1002/mrm.27175 Get It

PurposeTo build and evaluate a small‐footprint, lightweight, high‐performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole‐body clinical 3T MRI scanners, while achieving substantial reductions in installation costs.MethodsA conduction‐cooled magnet was developed that uses less than 12 liters of liquid helium in a gas‐charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42‐cm inner‐diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet‐gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80‐mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1‐MVA gradient drivers.ResultsIn a comparison of anatomical imaging in 16 patients using T2‐weighted 3D fluid‐attenuated inversion recovery (FLAIR) between the compact 3T and whole‐body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80‐mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain.ConclusionsThe compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole‐body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
Peripheral nerve stimulation characteristics of an asymmetric head‐only gradient coil compatible with a high‐channel‐count receiver array
Lee, Seung‐Kyun , Mathieu, Jean‐Baptiste, Graziani, Dominic, Piel, Joseph E., Budesheim, Eric, Fiveland, Eric, Hardy, Christopher J., Tan, Ek T. , Amm, Bruce, Foo, Thomas , Shu, Yunhong , Schenck, John F., Bernstein, Matt A. , Huston, John , Foo, Thomas K F , Tan, Ek T

Magnetic Resonance in Medicine | December 2, 2015 | Volume: 76 | Issue: 6 | Pages: 1939-1950

10.1002/mrm.26044 Get It

PurposeTo characterize peripheral nerve stimulation (PNS) of an asymmetric head‐only gradient coil that is compatible with a commercial high–channel‐count receive‐only array.MethodsTwo prototypes of an asymmetric head‐only gradient coil set with a 42‐cm inner diameter were constructed for brain imaging at 3T with maximum performance specifications of up to 85 mT/m and 708 T/m/s. Tests were performed in 24 volunteers to measure PNS thresholds with the transverse (x = left–right; y = anterior–posterior [A/P]) gradient coils of both prototypes. Fourteen of these 24 volunteers were also tested for the z‐gradient PNS in the second prototype and were scanned with high–slew‐rate echo planar imaging (EPI) immediately after the PNS tests.ResultsFor both prototypes, the y‐gradient PNS threshold was markedly higher than the x‐gradient threshold. The z‐gradient threshold was intermediate between those for the x‐ and y‐coils. Of the 24 volunteers, only two experienced y‐gradient PNS at 80 mT/m and 500 T/m/s. All volunteers underwent the EPI scan without PNS when the readout direction was set to A/P.ConclusionMeasured PNS characteristics of asymmetric head‐only gradient coil prototypes indicate that such coils, especially in the A/P direction, can be used for fast EPI readout in high‐performance neuroimaging scans with substantially reduced PNS concerns compared with conventional whole body gradient coils. Magn Reson Med 76:1939–1950, 2016. © 2015 International Society for Magnetic Resonance in Medicine