Back to Authors

Campeau, Norbert G.

https://orcid.org/0000-0002-0688-5781

Mayo Clinic

Mayo Clinic

Citations 30

Clinical benefits and current challenges of photon-counting detector CT in vascular imaging
Sadaney, Ahmed O El , Mark, Ian, Froemming, Adam T. , Baffour, Francis , Yu, Lifeng, Leng, Shuai, McCollough, Cynthia H, Leng, Shuai , El Sadaney, Ahmed O , Rajiah, Prabhakar Shantha, Campeau, Norbert G , Froemming, Adam T , Baffour, Francis I , Horst, Kelly K. , Yu, Lifeng , Leng, Shuai , McCollough, Cynthia H , Fletcher, Joel G , Diehn, Felix E. , Rajiah, Prabhakar , Mark, Ian, Campeau, Norbert G. , McCollough, Cynthia H. , Fletcher, Joel G.

Radiology Advances | April 14, 2026 | Volume: 3 | Issue: 3 | Pages: No page available

10.1093/radadv/umag021 Get It

Abstract Photon-counting detector CT (PCD-CT) directly detects individual photons and measures their energies, enabling the acquisition of multi-energy data from a single x-ray source with higher spatial resolution, thereby allowing visualization of smaller arteries and veins and other important imaging features not seen at conventional CT. It also substantially reduces calcium and stent blooming artifacts. Appropriate patient selection and task-based optimization of acquisition, reconstruction, and interpretation are critical to realize these benefits. Vascular imaging examinations for which early evidence shows that PCD-CT demonstrates higher diagnostic performance compared to conventional CT include coronary CT angiography (CTA) for evaluation of partially calcified plaques or stents, peripheral runoff CTA, detection of cerebrospinal fluid-venous fistulas, and head CTA for evaluation of small intracranial vessels and aneurysms. Current limitations include excessive image noise with the sharpest reconstruction kernels and challenges when adapting conventional CT protocols (eg, requiring sharper kernels, thinner slices, higher matrices, tailored scan modes) to achieve time-efficient image reconstruction and hanging protocols. New solutions and directions will include deep-learning-based image noise reduction, improved spectral separation, strategic triage of specific patient populations to PCD-CT systems, and subspecialty clinical practice recommendations for this new technology.
Cerebral Oxygen Budgeting: Network-Level BOLD Dynamics During Acute Hypoxia
Kang, Daehun, Haider, Clifton R. , In, Myung-Ho, Gray, Erin M. , Trzasko, Joshua D. , Welker, Kirk M., Senefeld, Jonathon W., Bernstein, Matt A., Holmes, David R., Joyner, M. J., Huston, John, Shu, Yunhong , Kang, Daehun , Kang, Daehun , Uchida, Koji, Curry, Timothy B. , Senefeld, Jonathon W , Uchida, Kôji , Campeau, Norbert G. , In, Myung‐Ho, Welker, Kirk M. , Wiggins, Chad C. , Senefeld, Jonathon W. , Baker, Sarah , Bernstein, Matt A. , Holmes, David R, Joyner, Michael J. , Huston, John

No container title available | March 31, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.03.27.713294 Get It

Abstract Hypoxia constrains cerebral oxygen availability and challenges brain function and stability. Although hypoxia-responsive functional connectivity (HR-FC) reorganizes rapidly with declining arterial oxygen partial pressure, its relationship to local neurovascular activity remains unclear. We examined time-resolved amplitude of low-frequency fluctuations (ALFF) in blood-oxygenation-level dependent (BOLD) fMRI during graded acute hypoxia in healthy adults, performing a continuous cognitive test (Go/No-go task) with concurrent physiological monitoring. Dynamic ALFF and functional connectivity were estimated using a sliding-window approach and analyzed across large-scale brain networks defined by Schaefer’s 17-network parcellation. Severe hypoxia elicited temporally dissociated responses across modalities. Functional connectivity increased monotonically, whereas ALFF exhibited pronounced nonlinear modulation, including phase-dependent divergence across networks. During hypoxic decompensation, the default mode network (DefaultA) showed marked ALFF suppression, whereas a ventral secondary somatosensory-dominant network (SomMotB) exhibited preferential preservation despite similar engagement in HR-FC. Together, these findings indicate that network-level ALFF captures a distinct yet complementary layer of functional dynamics, with a temporal profile distinct from functional connectivity. Spontaneous BOLD dynamics during acute hypoxia reflect structured network-level modulation rather than a uniform suppression attributable solely to reduced oxygen availability. These findings support a conceptual framework of cerebral oxygen budgeting , in which metabolic constraints reshape functional dynamics across brain networks.
Teaching NeuroImage: Miliary Perivascular Space Enhancement in Sepsis-Associated Posterior Reversible Encephalopathy Syndrome
Hutchinson, Valeria Ariza , Wijdicks, Eelco F M, Wijdicks, Eelco F. M. , Campeau, Norbert, Wijdicks, Eelco Fm , Ariza Hutchinson, Valeria , Campeau, Norbert G.

Neurology | January 22, 2026 | Volume: 106 | Issue: 4 | Pages: No page available

10.1212/wnl.0000000000214654 Get It

3D magnetization‐prepared rapid gradient echo with a RF saturation band on a compact 3T scanner
Speltz, Lydia J. Bardwell , In, Myung‐Ho , Trzasko, Joshua D. , Halverson, Maria, Gray, Erin M. , Shu, Yunhong , Bardwell Speltz, Lydia J , Gray, Erin, In, Myung-Ho , Kang, Daehun , Campeau, Norbert G. , Huston, John , Warner, David O. , Bernstein, Matt A.

Medical Physics | August 14, 2025 | Volume: 52 | Issue: 8 | Pages: No page available

10.1002/mp.18039 Get It

Abstract Background Flow‐related ghost artifact from a 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) sequence results from unsaturated magnetization of incoming arterial flow. This is especially common on MR scanners equipped with smaller radiofrequency (RF) transmit coils. A high‐performance compact 3T (C3T) scanner features a smaller RF‐transmit coil (inner diameter 37 cm, length 40 cm), leading to a rapid fall‐off of the B1 field below the neck. This configuration results in more intense flow‐related ghost artifacts, especially in younger patients. Purpose The C3T scanner's smaller RF‐transmit coil provides RF field coverage over the brain region, causing bright in‐flow arterial signals and flow‐related artifacts in the conventional 3D‐MPRAGE scans. The purpose of this study is to suppress these artifacts by adding a RF saturation band (RFSB) pulses to the 3D‐MPRAGE sequence. Methods The RFSB was added to the 3D‐MPRAGE sequence as a preparation pulse option. To test the effectiveness, 37 subjects were scanned on the C3T under an IRB‐approved protocol using 3D‐MPRAGE with and without RFSB. Ten of those subjects underwent repeated scans with and without RFSB to evaluate test‐retest reliability. A consensus evaluation by two neuroradiologists was performed on all data to compare signal to noise ratio, image contrast, presence of artifacts, and diagnostic confidence. Quantitative analysis included calculating test‐retest differences by image subtraction and evaluating the variance in flow‐artifact‐induced image intensity between the scans with and without RFSB. Additionally, one subject was scanned on a whole‐body 3T scanner using a transmit/receive (T/R) head coil to demonstrate the method's applicability across different MRI platforms as a proof of concept. Results The Wilcoxon signed‐rank test of the neuroradiologist evaluations showed a significant reduction in artifacts and an improvement in diagnostic confidence in the posterior fossa region with and without RFSB ( p < 0.0001). Test–retest analysis showed that adding RFSB significantly reduced image intensity variability in the cerebellum, even among subjects without visible flow artifacts. The normalized difference decreased from 8.71% to 6.41% ( p = 0.0059), suggesting improved image reliability in regions prone to flow‐related artifacts. Additionally, similar findings were observed in scans on a whole‐body 3T with a T/R head coil, demonstrating the broader applicability of this method. Conclusion Incorporating RFSB into 3D‐MPRAGE scans effectively reduces flow‐related ghost artifact on the C3T scanner, improving image quality and diagnostic confidence. These findings suggest that the proposed method could be widely implemented across MRI systems utilizing a smaller RF‐transmit coil.
Improved visualization of the chorda tympani with photon counting detector CT
Joseph, Annie K. , Farnsworth, Paul J. , Carlson, Matthew L. , Benson, John C. , Madhavan, Ajay A. , Lane, John I. , Benson, John , Madhavan, Ajay A , Farnsworth, Paul , Campeau, Norbert G. , Leng, Shuai

Clinical Neuroimaging | August 17, 2024 | Volume: 1 | Issue: 1-2 | Pages: No page available

10.1002/neo2.18 Get It

AbstractBackground and PurposeTo compare the performance of the photon‐counting detector (PCD)‐CT against a cutting‐edge energy‐integrated detector (EID)‐CT to visualize different segments of the chorda tympani nerve.Materials and MethodsAn IRB‐approved protocol prospectively enrolled patients for temporal bone CT on both EID‐CT and PCD‐CT scanners. Fellowship‐trained neuroradiologists compared visualization of chorda tympani segments on each scanner using a 5‐point Likert scale (1 indicating EID is far superior to PCD, 3 indicating they are equivalent, and 5 indicating PCD is far superior to EID). Scores were averaged across segments and tested using a one‐sample Wilcoxon signed‐rank test with a one‐sided alternative hypothesis.ResultsForty temporal bones were evaluated. Average Likert scores for visualization of chorda tympani segments‐chorda tympani canal/proximal segment, middle ear/posterior tympanic segment, and petrotympanic fissure/distal segment‐ on the PCD compared to EID scanner were 4.2 (SD = 0.4), 4.4 (0.5), and 4 (0.0), respectively. The anterior tympanic segment of the chorda tympani was not well visualized on either platform or therefore not scored. PCD compared to the EID scanner had better overall performance (Median = 4.2, 95% CI: [4.1, 5.0], p‐value < .001).ConclusionPCD‐CT improves visualization of the petrous and intratympanic chorda tympani nerve segments, chorda tympani canaliculus, and petrotympanic fissure compared to comparable EID‐CT examinations. The improved visualization of the chorda tympani is important for the characterization of middle ear pathology involving this structure and presurgical planning to determine the size of the facial recess for cochlear implantation and to estimate the risk of nerve injury.
Functional MR elastography measures visual cortex stiffening proportional to visual contrast intensity in regions of activation
Palnitkar, Harish , Murphy, Matthew C. , Glaser, Kevin J. , Welker, Kirk M. , Huston, John , Arani, Arvin , Palnitkar, Harish R, Campeau, Norbert, Arani, Arvin , Sui, Yi , Manduca, Armando , Campeau, Norbert G. , Ehman, Richard L.

Imaging Neuroscience | April 23, 2024 | Volume: 2 | Issue: No issue available | Pages: No page available

10.1162/imag_a_00172 Get It

Abstract Functional MRI (fMRI) is widely used to spatially localize neural activity in the brain associated with functional stimuli. Functional MR Elastography (fMRE) has recently been introduced as a complementary approach that measures the mechanical response to functional stimulus. The hypothesis of the current study is that the stiffness change in fMRE is proportional to the underlying neural activity. This hypothesis is tested by measuring the median stiffness change in the visual cortex as a function of luminance-matched contrast intensity of a checkerboard visual stimulus in 16 healthy subjects. The fMRE signal in the visual cortex was observed to be proportional to the contrast intensity of the visual stimulus. In regions of activation, fMRE signal increased in the range of 2 ± 1% to 5.8 ± 1% and fMRI signal increased by the expected 0.4 ± 0.2% to 0.9 ± 0.2%, for contrast levels of 5% to 100%, respectively. In conclusion, this study shows that the fMRE signal in the visual cortex can be directly modulated by the contrast intensity of a visual stimulus. The presence of some overlap between fMRI and fMRE regions of activation may suggest two distinct mechanisms governing the fMRI and fMRE signals, which will be investigated in future studies.
Volumetric T 2 ‐weighted spin echo imaging with improved SNR using localized
Kim, Dahan , Wang, Dinghui , Chao, Tzu Cheng , Pipe, James G. , Campeau, Norbert, Pipe, James G , Campeau, Norbert G.

Magnetic Resonance in Medicine | August 28, 2023 | Volume: 90 | Issue: 6 | Pages: 2261-2274

10.1002/mrm.29788 Get It

Abstract Purpose To demonstrate T 2 ‐weighted (single‐echo) spin‐echo (SE) imaging with near‐optimal acquisition efficiency by applying SNR‐efficient RF slice encoding and spiral readout. Methods A quadratic‐phase (frequency swept) excitation RF pulse replaced the conventional excitation in T 2 ‐weighted SE sequence to excite a thick slab that is internally spatially encoded by a variable phase along the slice direction. Highly overlapping slabs centered at every desired slice location were acquired in multiple passes, such that the entire imaging volume was excited by contiguous slabs in any given pass. Following 90° excitation, each slab was refocused with a conventional 180° RF to produce a SE signal, followed by a spiral in‐out readout. A noise‐insensitive reconstruction removed the quadratic phase in the spatial frequency domain, yielding desired slice resolution and improved SNR. Results Increasing the RF frequency sweep (hence, excitation width) allowed more frequent encoding of each slice over the multiple passes, improving final image SNR, until crosstalk ensued at excessive slab widths compared to their center‐to‐center spacing. With an optimized slab width, the proposed technique used all passes to acquire every prescribed slice, with substantially improved SNR over conventional SE or 2D‐turbo‐spin‐echo (TSE) scans. Quantitative SNR measurements indicated similar SNR as 3D‐TSE, but radiologist scoring favored 3D‐TSE, mainly because of spiral‐related artifacts and possibly because of regularized reconstructions in 3D‐TSE. Conclusion Using SNR‐efficient slice excitation scheme and spiral readout helped eliminate SNR and temporal inefficiencies in conventional T 2 ‐weighted imaging, yielding SNR independent of TR or number of passes.
High-resolution computed tomography angiography of the orbit using a photon-counting computed tomography scanner
Farnsworth, Paul J. , Yu, Lifeng , Leng, Shuai , Zhou, Zhongxing , Diehn, Felix E. , Leng, Shuai , Farnsworth, Paul , Campeau, Norbert G. , Yu, Lifeng , Fletcher, Joel G. , McCollough, Cynthia H.

Interventional Neuroradiology | July 4, 2023 | Volume: 31 | Issue: 4 | Pages: 539-554

10.1177/15910199231175198 Get It

Background and Purpose Recent introduction of photon counting detector (PCD) computed tomography (CT) scanners into clinical practice further improve CT angiography (CTA) depiction of orbital arterial vasculature compared to conventional energy integrating detector (EID) CT scanners. PCD-CTA of the orbit can provide a detailed arterial roadmap of the orbit which can de diagnostic on its own or serve as a helpful planning adjunct for both diagnostic and therapeutic catheter-based angiography of the orbit. Methods For this review, EID and PCD-CT imaging was obtained in 28 volunteers. The volume CT dose index was closely matched. A dual-energy scanning protocol was used on EID-CT. An ultra-high-resolution (UHR) scan mode was used on PCD-CT. Images were reconstructed at 0.6 mm slice thickness using a closely matched medium-sharp standard resolution (SR) kernel. High-resolution (HR) images with the sharpest quantitative kernel were also reconstructed on PCD-CT at the thinnest slice thickness of 0.2 mm. A denoising algorithm was applied to the HR image series. Results The imaging description of the orbital vascular anatomy presented in this work was derived from these patients’ PCD-CTA images in combination with review of the literature. We found that orbital arterial anatomy is much better depicted with PCD-CTA, and this work can serve primarily as an imaging atlas of the normal orbital vascular anatomy. Conclusion With recent advances in technology, arterial anatomy of the orbit is much better depicted with PCD-CTA as opposed to EID-CTA. Current orbital PCD-CTA technology approaches the necessary resolution threshold for reliable evaluation of central retinal artery occlusion.
Automated CT angiography collateral scoring in anterior large vessel occlusion stroke: A multireader study
Jabal, Mohamed Sobhi , Kallmes, David F. , Harston, George , Schwartz, Kara M., Benson, John C. , Little, Jason T. , Nagelschneider, Alex A. , Nasr, Deena M. , Braksick, Sherry A, Klaas, James P. , Bilgin, Cem , Brinjikji, Waleed , Campeau, Norbert, Schwartz, Kara, Messina, Steven, Carr, Carrie, Benson, John , Little, Jason, Nagelschneider, Alex, Madhavan, Ajay A , Nasr, Deena, Braksick, Sherry, Klaas, James, Bilgin, Cem , Campeau, Norbert G. , Messina, Steven A. , Carr, Carrie M. , Madhavan, Ajay A. , Scharf, Eugene

Interventional Neuroradiology | January 18, 2023 | Volume: 31 | Issue: 1 | Pages: 95-100

10.1177/15910199221150470 Get It

Background Computed tomography (CT) angiography collateral score (CTA-CS) is an important clinical outcome predictor following mechanical thrombectomy for ischemic stroke with large vessel occlusion (LVO). The present multireader study aimed to evaluate the performance of e-CTA software for automated assistance in CTA-CS scoring. Materials and Methods Brain CTA images of 56 patients with anterior LVO were retrospectively processed. Twelve readers of various clinical training, including junior neuroradiologists, senior neuroradiologists, and neurologists graded collateral flow using visual CTA-CS scale in two sessions separated by a washout period. Reference standard was the consensus of three expert readers. Duration of reading time, inter-rater reliability, and statistical comparison of readers’ performance metrics were analyzed between the e-CTA assisted and unassisted sessions. Results e-CTA assistance resulted in significant increase in mean accuracy (58.6% to 67.5%, p = 0.003), mean F1 score (0.574 to 0.676, p = 0.002), mean precision (58.8% to 68%, p = 0.007), and mean recall (58.7% to 69.9%, p = 0.002), especially with slight filling deficit (CTA-CS 2 and 3). Mean reading time was reduced across all readers (103.4 to 59.7 s, p = 0.001), and inter-rater agreement in CTA-CS assessment was increased (Krippendorff's alpha 0.366 to 0.676). Optimized occlusion laterality detection was also noted with mean accuracy (92.9% to 96.8%, p = 0.009). Conclusion Automated assistance for CTA-CS using e-CTA software provided helpful decision support for readers in terms of improving scoring accuracy and reading efficiency for physicians with a range of experience and training backgrounds and leading to significant improvements in inter-rater agreement.
Evaluation of a New, Highly Flexible Radiofrequency Coil for MR Simulation of Patients Undergoing External Beam Radiation Therapy
McGee, Kiaran P. , Campeau, Norbert G. , Witte, Robert J. , Rossman, Philip J., Christopherson, Jackie A., Tryggestad, E., Brinkmann, Debra H. , Daniel, J., Park, Sean S. , Rettmann, Dan , Robb, Fraser , Tryggestad, Erik J, Rettmann, Dan W , Campeau, Norbert G , McGee, Kiaran , Park, Sean S , Ma, Daniel J.

Journal of Clinical Medicine | October 11, 2022 | Volume: 11 | Issue: 20 | Pages: 5984

10.3390/jcm11205984 Get It

Purpose: To evaluate the performance of a new, highly flexible radiofrequency (RF) coil system for imaging patients undergoing MR simulation. Methods: Volumetric phantom and in vivo images were acquired with a commercially available and prototype RF coil set. Phantom evaluation was performed using a silicone-filled humanoid phantom of the head and shoulders. In vivo assessment was performed in five healthy and six patient subjects. Phantom data included T1-weighted volumetric imaging, while in vivo acquisitions included both T1- and T2-weighted volumetric imaging. Signal to noise ratio (SNR) and uniformity metrics were calculated in the phantom data, while SNR values were calculated in vivo. Statistical significance was tested by means of a non-parametric analysis of variance test. Results: At a threshold of p = 0.05, differences in measured SNR distributions within the entire phantom volume were statistically different in two of the three paired coil set comparisons. Differences in per slice average SNR between the two coil sets were all statistically significant, as well as differences in per slice image uniformity. For patients, SNRs within the entire imaging volume were statistically significantly different in four of the nine comparisons and seven of the nine comparisons performed on the per slice average SNR values. For healthy subjects, SNRs within the entire imaging volume were statistically significantly different in seven of the nine comparisons and eight of the nine comparisons when per slice average SNR was tested. Conclusions: Phantom and in vivo results demonstrate that image quality obtained from the novel flexible RF coil set was similar or improved over the conventional coil system. The results also demonstrate that image quality is impacted by the specific coil configurations used for imaging and should be matched appropriately to the anatomic site imaged to ensure optimal and reproducible image quality.