Back to Authors

Witte, Robert J.

https://orcid.org/0000-0001-9641-2787

Mayo Clinic

Mayo Clinic

Citations 12

The Use of Magnetic Resonance Imaging in Radiation Therapy Treatment Simulation and Planning
McGee, Kiaran P. , Yu, Victoria , Witte, Robert J. , Kishan, Amar U. , Valle, Luca , Wiesinger, Florian , De‐Colle, Chiara , Cao, Yue , Breen, William G. , Traughber, Bryan J, McGee, Kiaran , Cao, Minsong , Das, Indra J. , Traughber, Bryan

Journal of Magnetic Resonance Imaging | January 24, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/jmri.29246 Get It

Ever since its introduction as a diagnostic imaging tool the potential of magnetic resonance imaging (MRI) in radiation therapy (RT) treatment simulation and planning has been recognized. Recent technical advances have addressed many of the impediments to use of this technology and as a result have resulted in rapid and growing adoption of MRI in RT. The purpose of this article is to provide a broad review of the multiple uses of MR in the RT treatment simulation and planning process, identify several of the most used clinical scenarios in which MR is integral to the simulation and planning process, highlight existing limitations and provide multiple unmet needs thereby highlighting opportunities for the diagnostic MR imaging community to contribute and collaborate with our oncology colleagues.Evidence Level5Technical EfficacyStage 5
Morphometric Analysis on T1-Weighted MRI Complements Visual MRI Review in Focal Cortical Dysplasia (P4.073)
Quiroga, Diego Tovar, Witte, Robert J. , Almansa, Alexandra Santana , Brinkmann, Benjamin H. , Quiroga, Diego F. Tovar, Kenney‐Jung, Daniel , Britton, Jeffrey W. , Wong‐Kisiel, Lily C.

Neurology | December 7, 2023 | Volume: 88 | Issue: 16_supplement | Pages: No page available

10.1212/wnl.88.16_supplement.p4.073 Get It

The stronger the better - diagnostic utility of 7 Tesla MRI in epilepsy patients (4354)
Chalia, Mayur , Witte, Robert J. , Welker, Kirk M. , Panda, Ananya , Brinkmann, Benjamin H. , Britton, Jeffrey W. , Wong‐Kisiel, Lily C.

Neurology | December 7, 2023 | Volume: 96 | Issue: 15_supplement | Pages: No page available

10.1212/wnl.96.15_supplement.4354 Get It

Presurgical Evaluation and Surgical Outcomes in Medically Refractory Epilepsy and Temporal Encephalocele (2764)
Kanth, Kiran , Cascino, Gregory D. , Krecke, Karl N. , Witte, Robert J. , Britton, Jeffrey W. , Gompel, Jamie J. Van , Wong‐Kisiel, Lily C.

Neurology | December 7, 2023 | Volume: 94 | Issue: 15_supplement | Pages: No page available

10.1212/wnl.94.15_supplement.2764 Get It

Limited resection preserved verbal memory outcome in drug-resistant dominant temporal lobe epilepsy due to temporal encephaloceles (S24.002)
Smith, Kelsey , Alden, Eva , Kanth, Kiran , Krecke, Karl N. , Witte, Robert J. , So, Elson, Cascino, Gregory D. , Smith, Kelsey, Gompel, Jamie J. Van , So, Elson L., Britton, Jeffrey W. , Wong‐Kisiel, Lily C.

Neurology | December 6, 2023 | Volume: 98 | Issue: 18_supplement | Pages: No page available

10.1212/wnl.98.18_supplement.1735 Get It

EEG Source Localization in Temporal Encephaloceles: Concordance With Surgical Resection and Clinical Outcomes
Cox, Benjamin C. , Kanth, Kiran , Krecke, Karl N. , Witte, Robert J. , Brinkmann, Benjamin H. , Agashe, Shruti H, Wong-Kisiel, Lily C. , Brinkmann, Benjamin H , Agashe, Shruti , Smith, Kelsey M. , Gompel, Jamie J. Van , Wong‐Kisiel, Lily C.

Journal of Clinical Neurophysiology | September 27, 2023 | Volume: 41 | Issue: 6 | Pages: 515-521

10.1097/wnp.0000000000001021 Get It

Purpose: Temporal encephaloceles are a cause of drug-resistant temporal lobe epilepsy; however, their relationship with epileptogenesis is unclear, and optimal surgical resection is uncertain. EEG source localization (ESL) may guide surgical decision-making. Methods: We reviewed patients at Mayo Clinic Rochester with drug-resistant temporal lobe epilepsy and temporal encephaloceles, who underwent limited resection and had 1-year outcomes. EEG source localization was performed using standard density scalp EEG of ictal and interictal activity. Distance from dipole and standardized low-resolution brain electromagnetic tomography (sLORETA) solutions to the encephalocele were measured. Concordance of ESL with encephalocele and surgical resection was compared with 1-year surgical outcomes. Results: Seventeen patients met criteria. The mean distances from ESL results to encephalocele center for dipole and sLORETA analyses were 23 mm (SD 9) and 22 mm (SD 11), respectively. Ten patients (55.6%) had Engel I outcomes at 1 year. Dipole-encephalocele distance and sLORETA-encephalocele distance were significantly longer in patients with Engel I outcome and patients whose encephalocele was contained by sLORETA had worse outcome as well; however, multiple logistic regression analysis found that only containment of encephalocele by the sLORETA current density was significant (P < 0.05), odds ratio 0.12 (95% confidence interval [0.021, 0.71]). Conclusions: EEG source localization of scalp EEG localizes near encephaloceles, however, typically not in the encephalocele itself; this may be due to scalp EEG sampling propagated activity or alternatively that the seizure onset zone extends beyond the herniated cortex. Surprisingly, we observed increased ESL to encephalocele distances in patients with excellent surgical outcomes. Larger cohort studies including intracranial EEG data are needed to further explore this finding.
Evaluation of a New, Highly Flexible Radiofrequency Coil for MR Simulation of Patients Undergoing External Beam Radiation Therapy
McGee, Kiaran P. , Campeau, Norbert G. , Witte, Robert J. , Rossman, Philip J., Christopherson, Jackie A., Tryggestad, E., Brinkmann, Debra H. , Daniel, J., Park, Sean S. , Rettmann, Dan , Robb, Fraser , Tryggestad, Erik J, Rettmann, Dan W , Campeau, Norbert G , McGee, Kiaran , Park, Sean S , Ma, Daniel J.

Journal of Clinical Medicine | October 11, 2022 | Volume: 11 | Issue: 20 | Pages: 5984

10.3390/jcm11205984 Get It

Purpose: To evaluate the performance of a new, highly flexible radiofrequency (RF) coil system for imaging patients undergoing MR simulation. Methods: Volumetric phantom and in vivo images were acquired with a commercially available and prototype RF coil set. Phantom evaluation was performed using a silicone-filled humanoid phantom of the head and shoulders. In vivo assessment was performed in five healthy and six patient subjects. Phantom data included T1-weighted volumetric imaging, while in vivo acquisitions included both T1- and T2-weighted volumetric imaging. Signal to noise ratio (SNR) and uniformity metrics were calculated in the phantom data, while SNR values were calculated in vivo. Statistical significance was tested by means of a non-parametric analysis of variance test. Results: At a threshold of p = 0.05, differences in measured SNR distributions within the entire phantom volume were statistically different in two of the three paired coil set comparisons. Differences in per slice average SNR between the two coil sets were all statistically significant, as well as differences in per slice image uniformity. For patients, SNRs within the entire imaging volume were statistically significantly different in four of the nine comparisons and seven of the nine comparisons performed on the per slice average SNR values. For healthy subjects, SNRs within the entire imaging volume were statistically significantly different in seven of the nine comparisons and eight of the nine comparisons when per slice average SNR was tested. Conclusions: Phantom and in vivo results demonstrate that image quality obtained from the novel flexible RF coil set was similar or improved over the conventional coil system. The results also demonstrate that image quality is impacted by the specific coil configurations used for imaging and should be matched appropriately to the anatomic site imaged to ensure optimal and reproducible image quality.
Whole Brain 3D MR Fingerprinting in Multiple Sclerosis: A Pilot Investigation
Mostardeiro, Thomaz R. , Panda, Ananya , Witte, Robert J. , Lu, Aiming , McGee, Kiaran P. , Campeau, Norbert G. , Sui, Yi

No container title available | January 15, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-142251/v1 Get It

Abstract Background: MR fingerprinting (MRF) is a novel imaging method proposed for the diagnosis of Multiple Sclerosis (MS). This study aims to determine if MR Fingerprinting (MRF) relaxometry can differentiate frontal normal appearing white matter (F-NAWM) and splenium in patients diagnosed with MS as compared to controls and to characterize the relaxometry of demyelinating plaques relative to the time of diagnosis.Methods: Three-dimensional (3D) MRF data were acquired on a 3.0T MRI system resulting in isotropic voxels (1x1x1mm3) and a total acquisition time of 4min 38s. Data were collected on 18 subjects paired with 18 controls. Regions of interested were drawn over MRF-derived T1 relaxometry maps encompassing selected MS lesions, F-NAWM and splenium. T1 and T2 relaxometry features from those segmented areas were used to classify MS lesions from F-NAWM and splenium with T-distributed stochastic neighbor embedding algorithms (T-SNE). Partial least squares discriminant analysis (PLS-DA) was performed to discriminate NAWM and Splenium in MS compared with controls. Results: Mean out-of-fold machine learning prediction accuracy for discriminant results between MS patients and controls for F-NAWM was 65% and approached 90% for the splenium. There was significant positive correlation between time since diagnosis and MS lesions mean T2 (p=0.015), minimum T1 (p=0.03) and negative correlation with splenium uniformity (p=0.04). Perfect discrimination (AUC=1) was achieved between selected features from MS lesions and F-NAWM.Conclusions: 3D-MRF has the ability to differentiate between MS and controls based on relaxometry properties from the F-NAWM and splenium. Whole brain coverage allows the assessment of quantitative properties within lesions that provide chronological assessment of the time from MS diagnosis.
Segmentation errors and intertest reliability in automated and manually traced hippocampal volumes
Brinkmann, Benjamin H. , Kenney‐Jung, Daniel , Mandrekar, Jay , Watson, Robert E. , Welker, Kirk M. , Witte, Robert J. , Guragain, Hari, Watson, Robert E , Brinkmann, Benjamin H , Guragain, Hari, Britton, Jeffrey W.

Annals of Clinical and Translational Neurology | September 6, 2019 | Volume: 6 | Issue: 9 | Pages: 1807-1814

10.1002/acn3.50885 Get It

AbstractObjectiveTo rigorously compare automated atlas‐based and manual tracing hippocampal segmentation for accuracy, repeatability, and clinical acceptability given a relevant range of imaging abnormalities in clinical epilepsy.MethodsForty‐nine patients with hippocampal asymmetry were identified from our institutional radiology database, including two patients with significant anatomic deformations. Manual hippocampal tracing was performed by experienced technologists on 3T MPRAGE images, measuring hippocampal volume up to the tectal plate, excluding the hippocampal tail. The same images were processed using NeuroQuant and FreeSurfer software. Ten subjects underwent repeated manual hippocampal tracings by two additional technologists blinded to previous results to evaluate consistency. Ten patients with two clinical MRI studies had volume measurements repeated using NeuroQuant and FreeSurfer.ResultsFreeSurfer raw volumes were significantly lower than NeuroQuant (P < 0.001, right and left), and hippocampal asymmetry estimates were lower for both automatic methods than manual tracing (P < 0.0001). Differences remained significant after scaling volumes to age, gender, and scanner matched normative percentiles. Volume reproducibility was fair (0.4–0.59) for manual tracing, and excellent (>0.75) for both automated methods. Asymmetry index reproducibility was excellent (>0.75) for manual tracing and FreeSurfer segmentation and fair (0.4–0.59) for NeuroQuant segmentation. Both automatic segmentation methods failed on the two cases with anatomic deformations. Segmentation errors were visually identified in 25 NeuroQuant and 27 FreeSurfer segmentations, and nine (18%) NeuroQuant and six (12%) FreeSurfer errors were judged clinically significant.InterpretationAutomated hippocampal volumes are more reproducible than hand‐traced hippocampal volumes. However, these methods fail in some cases, and significant segmentation errors can occur.
Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography
Carlson, Matthew L. , Witte, Robert J. , Krecke, Karl N. , Grimes, Josh, Koeller, Kelly K. , Bruesewitz, Michael R. , Lane, John I. , Leng, Shuai , Diehn, Felix E. , McCollough, Cynthia H.

Otology & Neurotology | May 31, 2017 | Volume: 38 | Issue: 7 | Pages: 978-984

10.1097/mao.0000000000001463 Get It

Hypothesis: A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Background: Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Methods: Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Results: Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p < 0.01), superior scalar localization (p < 0.01), and reduced blooming artifact (p < 0.05), compared with conventional 64-slice MDCT. There was no significant difference between platforms when comparing streak or ring artifact. Conclusion: The new generation 192-slice MDCT scanner offers several notable advantages for cochlear implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.