Back to Authors

Brinkmann, Benjamin H.

https://orcid.org/0000-0002-2392-8608

Mayo Clinic

Mayo Clinic

Citations 89

Clinical utility of age-matched z-score maps from a large normative pediatric [18F]-FDG PET database for localizing epileptogenic abnormalities: illustrative cases
Lim, Seokbeen , Min, Paul H., Dizdar, Nur, Diaz, Miguel D., Guérin, J. , Silvera, Michelle, Wong-Kisiel, Lily C. , Salehinejad, Hojjat , Bilgin, Gokce Belge , Bilgin, Cem , Brinkmann, Benjamin H. , Britton, Jeffrey W. , Johnson, Derek R., Messina, Steven, Kemp, Bradley J. , Kendi, A. Tuba, Zhang, Jun, Lowe, Val J. , MD, Miller, Lim, Seokbeen

No container title available | September 24, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-11143642/v1 Get It

Abstract Introduction Quantitative interpretation of pediatric brain [ 18 F]-FDG PET is limited by the lack of age-matched normative reference databases, despite substantial developmental variation in cerebral glucose metabolism. This study aimed to construct a large-scale normative pediatric [ 18 F]-FDG PET database and develop an age-specific z-score mapping framework for quantitative evaluation of pediatric epilepsy. Method Pediatric brain PET data were retrospectively derived from clinically acquired whole-body or dedicated [ 18 F]-FDG PET examinations in participants 0–19 years of age without neurologic disease or visible brain abnormalities. A total of 417 PET scans from 341 participants were stratified into five developmental age groups: infancy, early childhood, middle childhood/school age, adolescence, and late adolescence. SUVR maps were generated using whole-brain atlas and brainstem reference regions. Voxel-wise t-test analyses were performed to characterize age- and sex-related metabolic differences. Age-specific voxel-wise mean and standard deviation maps were generated from the normative cohort and used to calculate age-matched hypometabolic z-score maps in 14 pediatric patients with epilepsy. The resulting abnormalities were qualitatively evaluated for concordance with epileptogenic findings identified on clinical MRI and/or PET by expert image review. Results Voxel-wise analyses demonstrated prominent age-dependent SUVR differences, particularly between infancy and older age groups. With whole-brain atlas normalization, older children showed progressively higher relative SUVR in cortical and cerebellar gray matter regions, whereas infancy showed relatively higher SUVR in the occipital cortex, white matter, thalamus, and brainstem. Brainstem normalization produced distinct developmental patterns, emphasizing higher white matter SUVR in infancy and broader gray matter differences in older groups. Sex-related differences were limited and regionally specific. Whole-brain atlas normalization showed lower variability than brainstem normalization and was selected for z-score mapping. In representative epilepsy cases, age-matched z-score maps identified focal or regional hypometabolism corresponding to malformations of cortical development, focal cortical dysplasia, mesial temporal sclerosis, nonlesional MRI cases, remote insult, tumor-related abnormalities, and Sturge-Weber syndrome. Discussion A large-scale normative pediatric [18F]-FDG PET database can support developmentally appropriate quantitative interpretation of pediatric brain PET. Age-matched z-score mapping may complement visual assessment by highlighting abnormal cerebral glucose metabolism in pediatric epilepsy, although findings should be interpreted with MRI, EEG, seizure semiology, and other presurgical data.
Seizure forecasting: The long and winding road to clinical translation
Stirling, Rachel E. , Cook, Mark , Goldenholz, Daniel M. , Rao, Vikram R. , Vieluf, Solveig , Brinkmann, Benjamin H. , Karoly, Phillipa J , Stirling, Rachel E , Cook, Mark J , Goldenholz, Daniel M , Baud, Maxime O , Rao, Vikram R , Vieluf, Solveig , Brinkmann, Benjamin H , Karoly, Philippa J. , Baud, Maxime O.

Epilepsia | July 20, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/epi.70394 Get It

Abstract Seizure forecasting has progressed from theoretical aspiration to a rapidly advancing research domain, yet clinical translation remains limited. Over the past decades, advances in algorithm development, chronic electroencephalography (EEG), wearable sensors, and the characterization of seizure cycles have demonstrated that seizure risk is not random but fluctuates according to identifiable biological rhythms and patient‐specific patterns. Forecasting algorithms have shown promising performance across diverse retrospective datasets, including intracranial EEG, subscalp recordings, wearable physiological signals, and even self‐reported diaries. However, the clinical value of forecasting is contentious. Prospective real‐world validation and regulatory approval of patient‐facing forecasting systems remain rare. This review incorporates perspectives presented at the 5th International Congress on Mobile Health and Digital Technology in Epilepsy (2025). We examine barriers impeding clinical translation and current attempts to address them. Crucially, forecasting performance cannot be evaluated in isolation from intended use. Applications range from low‐risk uses, like scheduling diagnostic monitoring or visualization of historical trends, to higher risk interventions, including medication titration and adaptive neuromodulation. Each application entails distinct performance thresholds, ethical considerations, and regulatory requirements. Translational challenges include reliable seizure annotation, nonstationarity dynamics of biological cycles, and practical constraints for real‐time deployment. Ethical concerns center on miscalibrated reliance on low‐risk states, potential anxiety associated with high‐risk advisories, and the heterogeneity of patient preferences and risk tolerance. Regulatory pathways are likely to depend on clearly defined use cases and clinically meaningful endpoints, which may extend beyond seizure counts to include quality of life, anxiety, locus of control, and other patient‐reported outcomes. Ultimately, translation will require rigorous prospective evaluation against transparent benchmarks, sustainable scientific–commercial partnerships, and integration of probabilistic risk information into clinical workflows. With careful implementation, seizure forecasting may evolve from proof‐of‐concept research into a clinically meaningful component of epilepsy management, and we remain cautiously optimistic.
Thalamocortical seizure onset patterns in drug-resistant focal epilepsy
Simpson, Hugh D. , Křemen, Václav , Sladky, Vladimir , Brinkmann, Benjamin H. , Gregg, Nicholas M. , Lundstrom, Brian N. , Miller, Kai J. , Brinkmann, Benjamin H , Kremen, Vaclav , Lundstrom, Brian Nils , Gregg, Nicholas M , Gompel, Jamie J. Van , Worrell, Gregory A.

Brain Communications | June 18, 2026 | Volume: 8 | Issue: 4 | Pages: No page available

10.1093/braincomms/fcag227 Get It

Abstract Drug-resistant epilepsy affects tens of millions of people worldwide and is associated with considerable morbidity and mortality. Thalamic deep brain stimulation and cortical responsive neurostimulation are proven treatments for focal epilepsy. Both have been used to target a range of thalamic nuclei; yet, the roles of these thalamic nuclei in focal seizure generation remain incompletely understood. Thirteen patients with drug-resistant focal epilepsy undergoing intracranial EEG were consented to undergo investigation of thalamocortical networks. Sampled regions included cortical, mesial temporal, and thalamic brain regions. Visual and spectral analyses were performed to identify seizure onset patterns and correlate thalamic and cortical seizure activity. Thalamic ictal discharges were observed in 89% of seizures. Of these, 56% demonstrated synchronous thalamocortical activity with distinct patterns. These onset patterns included hypersynchronous spiking, low-voltage fast activity, ictal baseline shifts, and broadband suppression. Multiple thalamic nuclei were involved in ictal organization and propagation, with the specific nuclei depending on the cortical seizure network. The thalamus plays a crucial role in focal onset seizure generation and propagation, with distinct seizure onset patterns and nuclei involved. These findings support exploring a broader range of thalamic nuclei in epilepsy neurostimulation and have implications for seizure detection settings in intracranial sensing devices.
Widening participation in the International League Against Epilepsy: Looking to the future
Cross, J. Helen , Coleman, Lauren, Oritz, Sebastian, Ivaniuk, Alina, Nome, Cecilie G. , Roza, Eugenia, Shafer, Patricia O. , Gaudecker, Jane von, Ryan, Chris, Brinkmann, Benjamin H. , Neuray, Caroline , Welty, Tim, Wiebe, Samuel , Guekht, Alla, Shafer, Patricia Osborne , Brinkmann, Benjamin H , Cross, Helen J , Ivaniuk, Alina , Roza, Eugenia , Gaudecker, Jane R. von , Wiebe, Samuel , Guekht, Alla B.

Epilepsia Open | April 28, 2026 | Volume: 11 | Issue: 3 | Pages: 719-726

10.1002/epi4.70272 Get It

Abstract The International League Against Epilepsy (ILAE) is a global organization dedicated to improving the lives of people with epilepsy through education, research, and advocacy. Recognizing the need for broader engagement and multidisciplinary collaboration, the ILAE has established five sections: Young Epilepsy Section (YES), Nursing, Social Work and Social Services (SWSSS), Neurotechnology, and Pharmacy. These sections aim to strengthen professional networks, enhance education, and promote innovation in epilepsy care. YES fosters leadership and participation among early‐career professionals, whereas the Nursing Section addresses gaps in epilepsy‐specific training and competency development. SWSSS emphasizes psychosocial care, advocacy, and health equity, supporting Intersectoral Global Action Plan (IGAP) objectives through culturally sensitive interventions. The Neurotechnology section advances the integration and development of innovative tools for diagnosis and treatment, and the Pharmacy section focuses on optimizing medication management and access to antiseizure medications globally. Collectively, these sections contribute to the WHO IGAP by improving policy, care delivery, research, and public health responses. Looking ahead, ILAE seeks to expand multidisciplinary participation, encourage cross‐sectional collaboration, and maintain its role as a leading force in global epilepsy care. Through these initiatives, ILAE continues to build capacity, foster inclusivity, and drive progress toward equitable, comprehensive epilepsy services worldwide. Plain Language Summary The International League Against Epilepsy (ILAE) is the global organization responsible for all healthcare professionals involved in the care of those with epilepsy. Recognizing the increasing number of different disciplines now contributing to epilepsy care, and the need to develop professionals of the future, the ILAE has recognized “sections” of like‐minded individuals to encourage networking and communication. Together, these sections contribute to the WHO Intersectoral Global Action Plan (IGAP) by improving policy, care delivery, research, and public health responses. Moving forward, the ILAE seeks to expand multidisciplinary participation, encourage collaboration, and maintain its role as a leading force in global epilepsy care.
Seizure burden and treatment efficacy evaluation in anti-LGI1 autoimmune encephalitis patients using wearable device: a pilot feasibility study
Cui, Jie , Duque-Lopez, Andrea, Brinkmann, Gabriella , Boney, Joseph, Ethridge, Julianna, Worrell, Gregory, Dubey, Divyanshu, Dubey, Divyanshu , Stabile, Andrea , Faust, Louis , Brinkmann, Benjamin, Dubey, Divyanshu , Cui, Jie , Worrell, Gregory A. , Brinkmann, Benjamin H.

BMJ Neurology Open | January 22, 2026 | Volume: 8 | Issue: 1 | Pages: e001403

10.1136/bmjno-2025-001403 Get It

Background Patients with anti-leucine-rich glioma-inactivated 1 (anti-LGI1) autoimmune encephalitis (AIE) frequently present with faciobrachial dystonic seizures (FBDS), which are often under-detected due to their subtle motor features and lack of consistent EEG correlates. Conventional in-hospital monitoring and patient-reported seizure diaries are limited, particularly during nocturnal periods. In this pilot feasibility study, we evaluated the use of a wearable device (Empatica E4) to objectively monitor FBDS-related motor and autonomic activity in seven patients with anti-LGI1 AIE and four control subjects. Methods Wearable recordings included accelerometry (ACC), electrodermal activity (EDA), photoplethysmography (PPG) and skin temperature. A support vector machine-based algorithm was developed to identify disorder-related events using ACC and EDA features. Analyses were restricted to sleep periods to minimise confounding from voluntary movements. Results Pretreatment recordings from two patients (P1 and P2) showed significantly elevated motor event frequency, ACC magnitude and EDA activity compared to controls. Post-treatment recordings demonstrated marked reductions in these metrics, consistent with patient-reported clinical improvement. Other patients showed variable results depending on treatment timing and signal quality. Conclusion Our pilot study demonstrates the feasibility of using wearable technology for objective, real-world monitoring and assessment of patient status in anti-LGI1 AIE. Nocturnal monitoring offers a low-noise baseline for detecting seizure-related activity and may support earlier diagnosis, more accurate evaluation of treatment response and reduced reliance on resource-intensive inpatient evaluations. Future studies should expand monitoring to daytime periods and validate findings against conventional modalities such as video-EEG and electromyography polygraphy.
Tracking seizure cycles beats a prospective moving average: Commentary on "Rigorous evaluation of five e‐diary alone seizure forecasting tools"
Stirling, Rachel E. , Brinkmann, Benjamin H. , Freestone, Dean R. , Karoly, Philippa J, Karoly, Phillipa J , Brinkmann, Benjamin H , Freestone, Dean R , Stirling, Rachel E , Karoly, Philippa J.

Epilepsia | December 31, 2025 | Volume: 67 | Issue: 4 | Pages: 1582-1586

10.1002/epi.70084 Get It

Abstract There is debate on the predictive value of multiday seizure cycles versus simple statistical baselines. Multidien seizure cyclicity is a prevalent, patient‐specific phenomenon with promise for epilepsy management. We challenge the assertion that cycle tracking is no better than a moving average, which is an inherently retrospective model that lags changes in seizure likelihood. This commentary compared a causal cyclic forecast to a prospectively applied moving average across a large seizure diary cohort ( n = 768) and two gold‐standard chronic EEG cohorts ( n = 24). For the EEG and diary cohorts, cycle tracking demonstrated significantly superior accuracy to the moving average for both hourly and daily forecasts ( p < 0.0001), using multiple performance metrics. These results confirm that event‐based cyclical models offer more accurate, simulated real‐world forecasts. Robust forecasting tools must prioritize the detection and modeling of seizure cycles to move beyond simple baseline performance and provide actionable clinical utility.
Seizure detection using ultra‐long‐term subcutaneous electroencephalography: A deep learning CNN ‐ BiLSTM approach
Park, Sihyeong , Clark, Jordan S., Viana, Pedro F. , Cui, Jie , Mandrekar, Jayawant N. , Gregg, Nicholas M. , Worrell, Gregory A. , Richardson, Mark P. , Brinkmann, Benjamin H. , Duun-Henriksen, Jonas , Gregg, Nicholas M , Worrell, Gregory A , Brinkmann, Benjamin H , Richardson, Mark P , Viana, Pedro F , Park, Sihyeong , Clark, Jordan S., Duun‐Henriksen, Jonas , Křemen, Václav

Epilepsia | October 8, 2025 | Volume: 67 | Issue: 1 | Pages: 437-447

10.1111/epi.18652 Get It

Abstract Objective This study reports development and validation of a deep learning seizure detection algorithm for two‐channel subscalp electroencephalographic (EEG) recordings. Ultra‐long‐term monitoring of people with epilepsy may produce new insights into the timing and pattern of their seizures and may pave the way for novel therapeutic options. Although EEG is the accepted standard for epilepsy monitoring, ultra‐long‐term EEG recordings generate a massive quantity of data and are not reasonably reviewable in full by human readers. Methods The convolutional neural network‐bidirectional long short‐term memory (CNN‐BiLSTM) hybrid algorithm uses nine layers, operating on channel spectrograms 5 min in length with 50% overlap. Retrospective subscalp EEG data from 16 patients recorded at three centers were available for algorithm development and testing. EEG was recorded for a median of 63 days (range = 9–508), and a median of 17 seizures (range = 0–96) were recorded. Training data were augmented with scalp EEG seizures, and performance was benchmarked against a conventional spectral power classifier algorithm. We also evaluated an intrapatient training–testing approach where the algorithm was trained on the first 45% of data. Results The CNN‐BiLSTM trained on scalp EEG and subscalp EEG achieved an area under the receiver operating characteristic curve (AUROC) of .98 and an area under the precision–recall curve (AUPRC) of .50, which correspond to 94% sensitivity with 1.11 false detections per day. The same model trained on iEEG achieved only AUROC = .94 and AUPRC = .36. The conventional spectral band power detector achieved AUROC = .93 and AUPRC = .38. The CNN‐BiLSTM detector trained on the earliest half of the subscalp EEG data achieved AUROC = .93 and AUPRC = .37, corresponding to 87% sensitivity and 5.9 false detections per day. Significance High sensitivity and specificity are possible in automated seizure detection in two‐channel subscalp EEG data using a CNN‐BiLSTM framework. Performance of the detector is superior using subcutaneous EEG data for training rather than intracranial EEG, but addition of scalp EEG seizures for training was helpful.
Detecting Diverse Seizure Types with Wrist-Worn Wearable Devices: A Comparison of Machine Learning Approaches
Faust, Louis , Cui, Jie, Knepper, Camille, Brinkmann, Benjamin H. , Nasseri, Mona , Brinkmann, Benjamin H , Cui, Jie , Worrell, Gregory A.

Sensors | September 8, 2025 | Volume: 25 | Issue: 17 | Pages: 5562

10.3390/s25175562 Get It

Objective: To evaluate the feasibility and effectiveness of wrist-worn wearable devices combined with machine learning (ML) approaches for detecting a diverse array of seizure types beyond generalized tonic–clonic (GTC), including focal, generalized, and subclinical seizures. Materials and Methods: Twenty-eight patients undergoing inpatient video-EEG monitoring at Mayo Clinic were concurrently monitored using Empatica E4 wrist-worn devices. These devices captured accelerometry, blood volume pulse, electrodermal activity, skin temperature, and heart rate. Seizures were annotated by neurologists. The data were preprocessed to experiment with various segment lengths (10 s and 60 s) and multiple feature sets. Three ML strategies, XGBoost, deep learning models (LSTM, CNN, Transformer), and ROCKET, were evaluated using leave-one-patient-out cross-validation. Performance was assessed using area under the receiver operating characteristic curve (AUROC), seizure-wise recall (SW-Recall), and false alarms per hour (FA/h). Results: Detection performance varied by seizure type and model. GTC seizures were detected most reliably (AUROC = 0.86, SW-Recall = 0.81, FA/h = 3.03). Hyperkinetic and tonic seizures showed high SW-Recall but also high FA/h. Subclinical and aware-dyscognitive seizures exhibited the lowest SW-Recall and highest FA/h. MultiROCKET and XGBoost performed best overall, though no single model was optimal for all seizure types. Longer segments (60 s) generally reduced FA/h. Feature set effectiveness varied, with multi-biosignal sets improving performance across seizure types. Conclusions: Wrist-worn wearables combined with ML can extend seizure detection beyond GTC seizures, though performance remains limited for non-motor types. Optimizing model selection, feature sets, and segment lengths, and minimizing false alarms, are key to clinical utility and real-world adoption.
Real‐world epilepsy monitoring with ultra‐long‐term subcutaneous electroencephalography: A 15‐month prospective study
Viana, Pedro F. , Biondi, Andrea , Winston, Joel S. , Freestone, Dean R. , Brinkmann, Benjamin H. , Richardson, Mark P. , Duun-Henriksen, Jonas , Biondi, Andrea , Winston, Joel S , Freestone, Dean R , Schulze-Bonhage, Andreas , Brinkmann, Benjamin H , Richardson, Mark P , Viana, Pedro F , Duun‐Henriksen, Jonas , Schulze‐Bonhage, Andreas

Epilepsia | July 19, 2025 | Volume: 66 | Issue: 11 | Pages: 4476-4489

10.1111/epi.18566 Get It

Abstract Objective Novel subcutaneous electroencephalography (sqEEG) systems enable prolonged, near‐continuous cerebral monitoring in real‐world conditions. Nevertheless, the feasibility, acceptability and overall clinical utility of these systems remain unclear. We report on the longest observational study using ultra‐long‐term sqEEG to date. Methods We conducted a 15‐month prospective, observational study including 10 adult people with treatment‐resistant epilepsy. After device implantation, patients were asked to record sqEEG, to use an electronic seizure diary, and to complete acceptability and usability questionnaires. sqEEG seizures were annotated visually, aided by automated detection. Individualized temporal patterns of seizure occurrence were assessed via circadian circular statistics and via Fano factor analysis. Results Over a median duration of 438 days, 10 patients recorded a median 18.8 h/day, totaling 71 984 h of real‐world sqEEG data. Adherence and acceptability remained high throughout the study. Although 754 sqEEG seizures were recorded across patients, more than half (52%) of these were not reported in the patient diary. Of the 140 (27%) diary reports not associated with an identifiable sqEEG seizure, the majority (68%) were reported as seizures with preserved awareness. The sqEEG to diary F1 agreement score was highly variable, ranging from .06 to .97. Patient‐specific patterns of circadian seizure occurrence and seizure clustering were found, including several relevant discrepancies between sqEEG and diary. Significance We demonstrate feasibility and high acceptability of ultra‐long‐term (months–years) sqEEG monitoring. These systems help provide real‐world, more objective seizure counting compared to patient diaries. It is possible to objectively monitor individual temporal fluctuations of seizure occurrence.
Thalamocortical network neuromodulation for epilepsy
Osman, Gamaleldin , Starnes, Keith , Sheffield, W. D., Leyde, Kent, Stead, Matt, Brinkmann, Benjamin H. , Miller, Kai J. , Gregg, Nicholas M. , Alcalá-Zermeño, Juan Luis , Osman, Gamaleldin M, Brinkmann, Benjamin H , Lundstrom, Brian Nils , Gregg, Nicholas M , Starnes, Donnie Keith , Agashe, Shruti , Sheffield, W Douglas, Stead, Matt, Gompel, Jamie J. Van , Worrell, Gregory A. , Lundstrom, Brian N.

Brain Communications | July 11, 2025 | Volume: 7 | Issue: 5 | Pages: No page available

10.1093/braincomms/fcaf270 Get It

Abstract Despite the growing interest in network-guided neuromodulation for epilepsy, uncertainty about the safety and long-term efficacy of thalamocortical stimulation persists. Our evaluation focused on the use of a four-lead open-loop implantable pulse generator for thalamocortical network neuromodulation. We retrospectively reviewed seven patients with diverse seizure networks—poorly localized, regional, or multifocal—undergoing thalamocortical neuromodulation. Employing a four-lead system, electrodes targeted both thalamic and cortical seizure network nodes. We assessed seizure severity, life satisfaction and sleep quality on a 10-point scale, and seizure frequency was assessed via telephone interviews and chart review. Outcomes were assessed by the Wilcoxon sign-rank test at the 0.05 significance level. Seven patients with a median age at implant of 22 years (range 14–42 years) had a median disabling seizure reduction of 93% (range 50–100%, P = 0.0156), with 100% responder rate (≥50% reduction in seizure frequency) after a median of 17 months post-implantation (range 13–60). The median improvement in seizure severity was 3.5 out of 10 points (P = 0.0312), life satisfaction 4.5 points (P = 0.0312) and quality of sleep 3 points (P = 0.062). No perioperative complications occurred. Transient seizure exacerbations (n = 2) and stimulation-related sensory/motor side-effects (n = 2) quickly resolved with parameter adjustments. One patient required surgical revision due to delayed infection. Six patients had permanent electrode placement refined by intracranial EEG trial stimulation; five patients had &gt;90% reduction in seizure frequency during trial stimulation. Thalamocortical network neuromodulation using a four-lead open-loop system is safe and associated with significant improvements in seizure control and patient quality of life. Trial stimulation during intracranial EEG shows promise for enhancing seizure network engagement and parameter optimization but requires further study. Prospective controlled trials are needed to further characterize and validate the efficacy and side-effect profile of thalamocortical network neuromodulation for epilepsy.