Back to Authors

Cui, Jie

0000-0003-1000-8869

Mayo Clinic

Department of Neurology, Bioelectronics Neurophysiology and Engineering Laboratory, Mayo Clinic, Minnesota, Rochester, USA.

Citations 3

Seizure burden and treatment efficacy evaluation in anti-LGI1 autoimmune encephalitis patients using wearable device: a pilot feasibility study
Cui, Jie , Duque-Lopez, Andrea, Brinkmann, Gabriella , Boney, Joseph, Ethridge, Julianna, Worrell, Gregory, Dubey, Divyanshu, Dubey, Divyanshu , Stabile, Andrea , Faust, Louis , Brinkmann, Benjamin, Dubey, Divyanshu , Cui, Jie , Worrell, Gregory A. , Brinkmann, Benjamin H.

BMJ Neurology Open | January 22, 2026 | Volume: 8 | Issue: 1 | Pages: e001403

10.1136/bmjno-2025-001403 Get It

Background Patients with anti-leucine-rich glioma-inactivated 1 (anti-LGI1) autoimmune encephalitis (AIE) frequently present with faciobrachial dystonic seizures (FBDS), which are often under-detected due to their subtle motor features and lack of consistent EEG correlates. Conventional in-hospital monitoring and patient-reported seizure diaries are limited, particularly during nocturnal periods. In this pilot feasibility study, we evaluated the use of a wearable device (Empatica E4) to objectively monitor FBDS-related motor and autonomic activity in seven patients with anti-LGI1 AIE and four control subjects. Methods Wearable recordings included accelerometry (ACC), electrodermal activity (EDA), photoplethysmography (PPG) and skin temperature. A support vector machine-based algorithm was developed to identify disorder-related events using ACC and EDA features. Analyses were restricted to sleep periods to minimise confounding from voluntary movements. Results Pretreatment recordings from two patients (P1 and P2) showed significantly elevated motor event frequency, ACC magnitude and EDA activity compared to controls. Post-treatment recordings demonstrated marked reductions in these metrics, consistent with patient-reported clinical improvement. Other patients showed variable results depending on treatment timing and signal quality. Conclusion Our pilot study demonstrates the feasibility of using wearable technology for objective, real-world monitoring and assessment of patient status in anti-LGI1 AIE. Nocturnal monitoring offers a low-noise baseline for detecting seizure-related activity and may support earlier diagnosis, more accurate evaluation of treatment response and reduced reliance on resource-intensive inpatient evaluations. Future studies should expand monitoring to daytime periods and validate findings against conventional modalities such as video-EEG and electromyography polygraphy.
Perceived seizure risk in epilepsy: Chronic electronic surveys with and without concurrent electroencephalography
Cui, Jie , Balzekas, Irena , Nurse, Ewan S. , Viana, Pedro F. , Gregg, Nicholas M. , Karoly, Philippa J. , Stirling, Rachel E. , Worrell, Gregory A. , Richardson, Mark P. , Brinkmann, Benjamin H. , Nurse, Ewan , Viana, Pedro F , Gregg, Nicholas M , Karoly, Phillipa J , Worrell, Gregory A , Brinkmann, Benjamin H , Richardson, Mark P , Cui, Jie , Stirling, Rachel E , Freestone, Dean R.

Epilepsia | June 12, 2023 | Volume: 64 | Issue: 9 | Pages: 2421-2433

10.1111/epi.17678 Get It

Abstract Objective Previous studies suggested that patients with epilepsy might be able to forecast their own seizures. This study aimed to assess the relationships between premonitory symptoms, perceived seizure risk, and future and recent self‐reported and electroencephalographically (EEG)‐confirmed seizures in ambulatory patients with epilepsy in their natural home environments. Methods Long‐term e‐surveys were collected from patients with and without concurrent EEG recordings. Information obtained from the e‐surveys included medication adherence, sleep quality, mood, stress, perceived seizure risk, and seizure occurrences preceding the survey. EEG seizures were identified. Univariate and multivariate generalized linear mixed‐effect regression models were used to estimate odds ratios (ORs) for the assessment of the relationships. Results were compared with the seizure forecasting classifiers and device forecasting literature using a mathematical formula converting OR to equivalent area under the curve (AUC). Results Fifty‐four subjects returned 10 269 e‐survey entries, with four subjects acquiring concurrent EEG recordings. Univariate analysis revealed that increased stress (OR = 2.01, 95% confidence interval [CI] = 1.12–3.61, AUC = .61, p = .02) was associated with increased relative odds of future self‐reported seizures. Multivariate analysis showed that previous self‐reported seizures (OR = 5.37, 95% CI = 3.53–8.16, AUC = .76, p < .001) were most strongly associated with future self‐reported seizures, and high perceived seizure risk (OR = 3.34, 95% CI = 1.87–5.95, AUC = .69, p < .001) remained significant when prior self‐reported seizures were added to the model. No correlation with medication adherence was found. No significant association was found between e‐survey responses and subsequent EEG seizures. Significance Our results suggest that patients may tend to self‐forecast seizures that occur in sequential groupings and that low mood and increased stress may be the result of previous seizures rather than independent premonitory symptoms. Patients in the small cohort with concurrent EEG showed no ability to self‐predict EEG seizures. The conversion from OR to AUC values facilitates direct comparison of performance between survey and device studies involving survey premonition and forecasting.
Seizure occurrence is linked to multiday cycles in diverse physiological signals
Gregg, Nicholas M. , Attia, Tal Pal , Nasseri, Mona , Karoly, Philippa J. , Cui, Jie , Stirling, Rachel E. , Viana, Pedro F. , Nurse, Ewan S. , Cook, Mark , Richardson, Mark P. , Brinkmann, Benjamin H. , Pal Attia, Tal , Joseph, Boney , Karoly, Phillipa J , Cui, Jie , Stirling, Rachel E , Viana, Pedro F , Richner, Thomas J, Nurse, Ewan , Schulze-Bonhage, Andreas , Cook, Mark J , Worrell, Gregory A , Richardson, Mark P , Freestone, Dean R , Brinkmann, Benjamin H , Gregg, Nicholas M , Joseph, Boney , Richner, Thomas J. , Schulze‐Bonhage, Andreas , Worrell, Gregory A. , Freestone, Dean R.

Epilepsia | April 15, 2023 | Volume: 64 | Issue: 6 | Pages: 1627-1639

10.1111/epi.17607 Get It

Abstract Objective The factors that influence seizure timing are poorly understood, and seizure unpredictability remains a major cause of disability. Work in chronobiology has shown that cyclical physiological phenomena are ubiquitous, with daily and multiday cycles evident in immune, endocrine, metabolic, neurological, and cardiovascular function. Additionally, work with chronic brain recordings has identified that seizure risk is linked to daily and multiday cycles in brain activity. Here, we provide the first characterization of the relationships between the cyclical modulation of a diverse set of physiological signals, brain activity, and seizure timing. Methods In this cohort study, 14 subjects underwent chronic ambulatory monitoring with a multimodal wrist‐worn sensor (recording heart rate, accelerometry, electrodermal activity, and temperature) and an implanted responsive neurostimulation system (recording interictal epileptiform abnormalities and electrographic seizures). Wavelet and filter–Hilbert spectral analyses characterized circadian and multiday cycles in brain and wearable recordings. Circular statistics assessed electrographic seizure timing and cycles in physiology. Results Ten subjects met inclusion criteria. The mean recording duration was 232 days. Seven subjects had reliable electroencephalographic seizure detections (mean = 76 seizures). Multiday cycles were present in all wearable device signals across all subjects. Seizure timing was phase locked to multiday cycles in five (temperature), four (heart rate, phasic electrodermal activity), and three (accelerometry, heart rate variability, tonic electrodermal activity) subjects. Notably, after regression of behavioral covariates from heart rate, six of seven subjects had seizure phase locking to the residual heart rate signal. Significance Seizure timing is associated with daily and multiday cycles in multiple physiological processes. Chronic multimodal wearable device recordings can situate rare paroxysmal events, like seizures, within a broader chronobiology context of the individual. Wearable devices may advance the understanding of factors that influence seizure risk and enable personalized time‐varying approaches to epilepsy care.