Abstract Objective Anterior nucleus of the thalamus (ANT) deep brain stimulation (DBS) is an effective therapy for frontotemporal and limbic drug‐resistant focal epilepsies. The pulvinar nucleus (PUL) is an emerging neuromodulation target for seizure networks involving the posterior quadrant and temporal lobe. This study evaluates the safety and effectiveness of combined bilateral ANT plus PUL DBS for posterior quadrant and temporal lobe epilepsies. Methods We conducted a single‐center retrospective cohort study of patients receiving combined ANT/PUL DBS between 2021 and 2025. Outcomes included median seizure rate reduction (MSR), responder rate (RR; >50% seizure frequency reduction), and stimulation‐related side effects, assessed across ANT, PUL, and concurrent ANT/PUL stimulation settings. Acute surgical complications were evaluated. Statistical significance was assessed using two‐sided Wilcoxon signed‐rank tests with Holm–Bonferroni correction. Results Nine patients with combined ANT/PUL DBS were identified, and eight patients had sufficient follow‐up for inclusion (median follow‐up = 20 months). Posterior predominant structural abnormalities were present in eight of nine patients. There were no acute surgical complications. Three instances of transient stimulation‐related side effects resolved with parameter adjustments, whereas one patient required rescue antiseizure medication in addition to programming changes. Eight patients received periods of ANT stimulation, six PUL stimulation, and seven combined ANT/PUL stimulation. Regarding overall outcome, at last follow‐up, there was a significant 80.8% MSR ( p = .0078) and 87.5% RR, with two patients receiving ANT and six ANT/PUL stimulation. Regarding target‐specific MSR, concurrent ANT/PUL DBS (68.8% MSR) showed a trend toward superior performance relative to ANT (43.3%) and PUL DBS (17.5%) alone, although subgroup analysis of target‐specific performance did not reach statistical significance. Significance Combined four‐lead ANT/PUL DBS appears safe and effective for patients with drug‐resistant posterior quadrant and temporal lobe epilepsies. Dual‐network neuromodulation may provide greater flexibility to individually optimize neuromodulation for complex seizure networks.
Local field potentials for target localization in centromedian deep brain stimulation for epilepsy
Objective To evaluate whether local field potential (LFP) spectral profiles can serve as a candidate “spectral fingerprint” for physiological confirmation of centromedian-parafascicular (CM–Pf) targeting during thalamic deep brain stimulation (DBS) for drug resistant epilepsy (DRE). Methods This is a retrospective study of 10 patients (20 leads) who underwent CM-DBS implantation for DRE at a single tertiary center. Postoperative CT and preoperative MRI were co-registered, normalized to the Montreal Neurological Institute (MNI) space, and reconstructed using Lead-DBS software to anatomically localize contacts. BrainSense™ Survey recordings were obtained at least 3 weeks post-implant during routine programming. LFP frequency content was analyzed, and prominent peaks were identified and classified into canonical frequency bands (theta, alpha, beta). These spectral profiles were then mapped to MRI-based anatomical localizations, and statistical tests were applied to assess associations between peak patterns, contact localizations and thalamic subregions. Results Contacts were distributed as follows: 50 in the CM, 16 in the Parafascicular (Pf), 15 in the Centrolateral, 8 in the Mediodorsal, and 7 in the Ventrolateral (VL) nuclei. Of the 10 representative spectral localizations confined to the CM/CM-Pf region, 8 (80%) displayed a distinct dual-peak spectral profile with peaks in the theta/low alpha (5.5–9 Hz) and high beta (20–30 Hz) bands (mean frequencies: 7.63 Hz and 21.02 Hz, Fisher’s exact test, p < 0.001). Single-peak profiles showed no significant association with specific nuclei ( p = 0.871). Contacts overlapping other thalamic nuclei more frequently exhibited narrow 10–15 Hz peaks ( p = 0.005) or triple-peak profiles ( p = 0.02), suggesting mixed structural contributions. Conclusion A dual- band candidate spectral pattern consisting of theta/low alpha and high beta peaks was associated with the CM-Pf region in this cohort. This finding provides early evidence supporting the feasibility of incorporating passive LFP recordings as a physiologic marker of target engagement. Future work to prospectively compare bipolar survey-based localization with monopolar recording strategies could enable development of a state-based, physiologically informed spectral atlas to refine CM-Pf targeting in thalamic neuromodulation for DRE.
Seizure detection using ultra‐long‐term subcutaneous electroencephalography: A deep learning
CNN
‐
BiLSTM
approach
Abstract Objective This study reports development and validation of a deep learning seizure detection algorithm for two‐channel subscalp electroencephalographic (EEG) recordings. Ultra‐long‐term monitoring of people with epilepsy may produce new insights into the timing and pattern of their seizures and may pave the way for novel therapeutic options. Although EEG is the accepted standard for epilepsy monitoring, ultra‐long‐term EEG recordings generate a massive quantity of data and are not reasonably reviewable in full by human readers. Methods The convolutional neural network‐bidirectional long short‐term memory (CNN‐BiLSTM) hybrid algorithm uses nine layers, operating on channel spectrograms 5 min in length with 50% overlap. Retrospective subscalp EEG data from 16 patients recorded at three centers were available for algorithm development and testing. EEG was recorded for a median of 63 days (range = 9–508), and a median of 17 seizures (range = 0–96) were recorded. Training data were augmented with scalp EEG seizures, and performance was benchmarked against a conventional spectral power classifier algorithm. We also evaluated an intrapatient training–testing approach where the algorithm was trained on the first 45% of data. Results The CNN‐BiLSTM trained on scalp EEG and subscalp EEG achieved an area under the receiver operating characteristic curve (AUROC) of .98 and an area under the precision–recall curve (AUPRC) of .50, which correspond to 94% sensitivity with 1.11 false detections per day. The same model trained on iEEG achieved only AUROC = .94 and AUPRC = .36. The conventional spectral band power detector achieved AUROC = .93 and AUPRC = .38. The CNN‐BiLSTM detector trained on the earliest half of the subscalp EEG data achieved AUROC = .93 and AUPRC = .37, corresponding to 87% sensitivity and 5.9 false detections per day. Significance High sensitivity and specificity are possible in automated seizure detection in two‐channel subscalp EEG data using a CNN‐BiLSTM framework. Performance of the detector is superior using subcutaneous EEG data for training rather than intracranial EEG, but addition of scalp EEG seizures for training was helpful.
Seizure Detection and Lateralization Using Thalamic Deep Brain Stimulator Recordings
Summary: The lack of reliable seizure detection remains a significant challenge for epilepsy care. A clinical deep brain stimulation (DBS) system provides constrained ambulatory brain recordings; however, limited data exist on the use of DBS recordings for seizure detection and lateralization. We present the case of an 18-year-old patient with drug-resistant focal epilepsy, who had seizure detection and lateralization by DBS recordings. Prior stereotactic-EEG, including a thalamus lead, identified independent left orbitofrontal and mesial temporal onset seizures. Notably, low-frequency thalamic ictal power was significantly elevated relative to baseline awake and sleep states. The patient was subsequently implanted with an anterior nucleus of the thalamus DBS system. Postimplantation, low-frequency power-in-band (5.3–10.3 Hz) recordings were initiated. Nursing staff identified four typical clinical seizures during the inpatient DBS recording period. Thalamic DBS trends contained relative peaks that were coincident with each nurse-reported seizure. Peri-ictal power was uniformly maximal ipsilateral to the seizure network. This case demonstrates the feasibility of seizure detection and lateralization by a thalamic DBS system for some individuals, and suggests DBS sensing parameter selection may be guided by thalamic stereotactic EEG. Further research is necessary to assess the generalizability of DBS seizure detection across individuals and diverse seizure networks.
Centromedian thalamic deep brain stimulation for idiopathic generalized epilepsy: Connectivity and target optimization
Abstract There are limited treatment options for individuals with drug‐resistant idiopathic generalized epilepsy (IGE). Small, limited case series suggest that centromedian thalamus deep brain stimulation (CM‐DBS) may be an effective treatment option. The optimal CM‐DBS target for IGE is underexamined. Here, we present a retrospective analysis of CM‐DBS targeting and efficacy for five patients with drug‐resistant IGE. Volume of tissue activated (VTA) overlap with CM nucleus was performed using an open‐source toolbox. Median follow‐up time was 13 months. Median convulsive seizure frequency reduction was 66%. One patient had only absence seizures, with >99% reduction in absence seizure frequency. Four patients had electrode contacts positioned within the CM nucleus target, all of whom had >50% reduction in primary semiology seizure, with 85% median seizure reduction ( p = .004, paired‐sample t test). Volumetric “sweet‐spot” mapping revealed that best outcomes were correlated with stimulation of the middle ventral CM nucleus. Connectivity strength between the sweet‐spot region and central peri‐Rolandic cortex was increased significantly relative to other cortical regions ( p = 8.6 × 10 −4 , Mann–Whitney U test). Our findings indicate that CM‐DBS can be an effective treatment for patients with IGE, highlight the importance of accurate targeting and targeting analysis, and within the context of prior work, suggest that ideal CM‐DBS targets may be syndrome specific.