Abstract Photon-counting detector CT (PCD-CT) directly detects individual photons and measures their energies, enabling the acquisition of multi-energy data from a single x-ray source with higher spatial resolution, thereby allowing visualization of smaller arteries and veins and other important imaging features not seen at conventional CT. It also substantially reduces calcium and stent blooming artifacts. Appropriate patient selection and task-based optimization of acquisition, reconstruction, and interpretation are critical to realize these benefits. Vascular imaging examinations for which early evidence shows that PCD-CT demonstrates higher diagnostic performance compared to conventional CT include coronary CT angiography (CTA) for evaluation of partially calcified plaques or stents, peripheral runoff CTA, detection of cerebrospinal fluid-venous fistulas, and head CTA for evaluation of small intracranial vessels and aneurysms. Current limitations include excessive image noise with the sharpest reconstruction kernels and challenges when adapting conventional CT protocols (eg, requiring sharper kernels, thinner slices, higher matrices, tailored scan modes) to achieve time-efficient image reconstruction and hanging protocols. New solutions and directions will include deep-learning-based image noise reduction, improved spectral separation, strategic triage of specific patient populations to PCD-CT systems, and subspecialty clinical practice recommendations for this new technology.
Aberrant ICA and Associated Skull Base Foramina Visualized on Photon Counting Detector CT: Interesting Images
Aberrant internal carotid arteries (ICA) are congenital vascular anomalies that occur from involution of the cervical portion of the ICA, which leads to enlargement of the normally small collateral inferior tympanic and caroticotympanic arteries. The inferior tympanic artery is a branch of the external carotid artery, usually the ascending pharyngeal artery, which extends through the inferior tympanic canaliculus (ITC), a small foramen located along the cochlea promontory. Aberrant ICAs can also be associated with a persistent stapedial artery (PSA), which is an abnormal vessel that arises from the petrous ICA and passes through the obturator foramen of the stapes. An aberrant ICA is a very important anomaly to recognize on imaging. Accurately describing its presence is important to help prevent iatrogenic injury during intervention. It is also important to distinguish an aberrant ICA from a lateralized ICA. The improvement of spatial resolution with photon counting detector (PCD)-CT has been proven to provide higher performance in detection of sub-centimeter vascular lesions compared to conventional energy-integrated detector (EID)-CT. PCD-CT also provides superior visualization of small skull-based foramina such as the inferior tympanic canaliculus, which can aid in more accurately characterizing an aberrant ICA (variant course without ITC involvement).
New Imaging Modality in Craniocervical Artery Dissections: Photon Counting Computed Tomography Angiography
What Is the Accuracy of 16S PCR Followed by Sanger Sequencing or Next-generation Sequencing in Native Vertebral Osteomyelitis? A Systematic Review and Meta-analysis
Background Identifying a microorganism in patients with native vertebral osteomyelitis presents diagnostic challenges. Microorganism identification through culture-based methods is constrained by prolonged processing times and sensitivity limitations. Despite the availability of molecular diagnostic techniques for identifying microorganisms in native vertebral osteomyelitis, there is considerable variability in reported sensitivity and specificity across studies, leading to uncertainty in their clinical utility. Questions/purposes What are the sensitivity, specificity, and diagnostic odds ratios for 16S broad-range PCR followed by Sanger sequencing (16S) and metagenomic next-generation sequencing (NGS) for detecting bacteria in native vertebral osteomyelitis? Methods On June 29, 2023, we searched Cochrane, Embase, Medline, and Scopus for results from January 1970 to June 2023. Included studies involved adult patients with suspected native vertebral osteomyelitis undergoing molecular diagnostics—16S bacterial broad-range PCR followed by Sanger sequencing and shotgun or targeted metagenomic NGS—for bacteria detection. Studies involving nonnative vertebral osteomyelitis and cases of brucellar, tubercular, or fungal etiology were excluded. The reference standard for the diagnosis of native vertebral osteomyelitis was a composite clinical- and investigator-defined native vertebral osteomyelitis diagnosis. Diagnostic performance was assessed using a bivariate random-effects model. Risk of bias and diagnostic applicability were evaluated using the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. After a manual screening of 3403 studies, 10 studies (5 on 16S, 5 on NGS) were included in the present analysis, from which 391 patients were included from a total of 958 patients overall. Quality assessment via QUADAS-2 criteria showed moderate risk of bias and good applicability. Results 16S showed 78% (95% confidence interval [CI] 95% CI 31% to 96%) sensitivity and 94% (95% CI 73% to 99%) specificity, whereas NGS demonstrated 82% (95% CI 63% to 93%) sensitivity and 71% (95% CI 37% to 91%) specificity. In addition, the diagnostic ORs were 59 (95% CI 9 to 388) and 11 (95% CI 4 to 35) for 16S and NGS, respectively. Summary receiver operating characteristic curves showed high test performance for 16S (area under the curve for 16S 95% [95% CI 93% to 97%] and for NGS 89% [95% CI 86% to 92%]). Certainty in estimates was moderate because of sample size limitations. Conclusion This meta-analysis found moderate-to-high diagnostic performance of molecular methods on direct patient specimens for the diagnosis of native vertebral osteomyelitis. When used as a complementary test to microbiological analyses, a positive 16S result rules in the diagnosis of native vertebral osteomyelitis, while further studies are needed to understand the role of NGS in the diagnosis of native vertebral osteomyelitis. When available, these tests should be used in addition to conventional microbiology, especially in complex cases with extensively negative standard microbiological test results, to detect fastidious bacteria or to confirm the causative bacteria when their isolation and pathogenicity are unclear. A large sample size is needed in future research to understand the use of these techniques as standalone tests for diagnosis. Level of Evidence Level III, diagnostic study.
Feasibility of thin-slice, low noise images created using multi-kernel synthesis to replace multiple image series in head CT
Background SynthesiZed Improved Resolution and Concurrent nOise reductioN (ZIRCON) is a multi-kernel synthesis method that creates a single series of thin-slice computed tomography (CT) images displaying low noise and high spatial resolution, increasing reader efficiency and minimizing partial volume averaging. Purpose To compare the diagnostic performance of a single set of ZIRCON images to two routine clinical image series using conventional CT head and bone reconstruction kernels for diagnosing intracranial findings and fractures in patients with trauma or suspected acute neurologic deficit. Material and Methods In total, 50 patients underwent clinically indicated head CT in the ER (15 normal, 35 abnormal cases). A non-reader neuroradiologist established the reference standard. Three neuroradiologists reviewed two routine clinical series (head and bone kernels) and a single ZIRCON series, detecting intracranial findings or fractures and rating confidence (0–100). Sensitivity, specificity, and jackknife free-response receiver operating characteristic (JAFROC) figure of merit (FOM) were compared (limit of non-inferiority: −0.10). Results ZIRCON and conventional images demonstrated comparable performance for fractures (sensitivity: 51.5% vs. 54.5%; specificity: 40.2% vs. 34.2%) and intracranial findings (sensitivity: 88.2% vs. 91.4%; specificity: 77.2% vs. 73.7%).The estimated difference of JAFROC FOM demonstrated ZIRCON non-inferiority for acute pathologies overall (0.003 [95% CI=−0.051–0.057]) and fractures (0.048 [95% CI=−0.050–0.145]) but not for intracranial findings alone (−0.024 [95% CI=−0.100–0.052]). Conclusion Thin-slice, low noise, and high spatial resolution images can be created to display intracranial findings and fractures replacing multiple images series in head CT with similar performance. Future studies in more patients and further algorithmic development are warranted.
Intracranial findings in spontaneous intracranial hypotension: Does the severity of abnormalities correspond with certainty and/or multifocality of cerebrospinal fluid leaks?
Background and Purpose Spontaneous intracranial hypotension (SIH) is caused by spinal cerebrospinal fluid (CSF) leaks. This study assessed whether the certainty and/or multifocality of CSF leaks is associated with the severity of intracranial sequelae of SIH. Materials and Methods A retrospective review was completed of patients with suspected SIH that underwent digital subtraction myelogram (DSM) preceded by brain MRI. DSMs were evaluated for the presence or absence of a CSF leak, categorized both as positive/negative/indeterminate and single versus multifocal. Brain MRIs were assessed for intracranial sequelae of SIH based on two probabilistic scoring systems (Dobrocky and Mayo methods). For each system, both an absolute “numerical” score (based on tabulation of findings) and “categorized” score (classification of probability) were tabulated. Results 174 patients were included; 113 (64.9%) were female, average age 52.0 ± 14.3 years. One or more definite leaks were noted in 76 (43.7%) patients; an indeterminate leak was noted in 22 (12.6%) patients. 16 (16.3%) had multiple leaks. There was no significant difference in the severity of intracranial findings between patients with a single versus multiple leaks ( p values ranged from .36 to .70 using categorized scores and 0.22–0.99 for numerical scores). Definite leaks were more likely to have both higher categorized intracranial scores (Mayo p = .0008, Dobrocky p = .006) and numerical scores ( p = .0002 for Mayo and p = .006 for Dobrocky). Conclusions Certainty of a CSF leak on diagnostic imaging is associated with severity of intracranial sequelae of SIH, with definite leaks having significantly more intracranial findings than indeterminate leaks. Multifocal leaks do not cause greater intracranial abnormalities.
High yield clinical applications for photon counting CT in neurovascular imaging
Abstract Photon-counting CT (PCCT) uses a novel X-ray detection mechanism that confers many advantages over that used in traditional energy integrating CT. As PCCT becomes more available, it is important to thoroughly understand its benefits and highest yield areas for improvements in diagnosis of various diseases. Based on our early experience, we have identified several areas of neurovascular imaging in which PCCT shows promise. Here, we describe the benefits in diagnosing arterial and venous diseases in the head, neck, and spine. Specifically, we focus on applications in head and neck CT angiography (CTA), spinal CT angiography, and CT myelography for detection of CSF-venous fistulas. Each of these applications highlights the technological advantages of PCCT in neurovascular imaging. Further understanding of these applications will not only benefit institutions incorporating PCCT into their practices but will also help guide future directions for implementation of PCCT for diagnosing other pathologies in neuroimaging.
Photon-Counting Detector CT Angiography in Cervical Artery Dissection
Epidural steroid injections are commonly performed using fluoroscopic or CT guidance. With both modalities, the injection of contrast material is necessary before steroid administration to ensure adequate epidural flow and exclude non-epidural flow. While fluoroscopic guidance is conventional, CT is utilized at some centers and can be particularly helpful in the setting of challenging or postoperative anatomy. It is important for proceduralists to be adept at evaluating contrast media flow patterns under both modalities. The goal of this review article is to describe and provide examples of epidural and non-epidural flow patterns on both conventional fluoroscopy and CT. Specific non-epidural patterns discussed include intrathecal flow, intradural/subdural flow, vascular uptake, flow into the retrodural space of Okada, inadvertent facet joint flow, and intradiscal flow.
Immune checkpoint inhibitor-associated myopathy: Clinicoseropathological Phenotype and Survival Analysis (1949)