Back to Authors

Farnsworth, Paul J.

https://orcid.org/0000-0002-3955-6722

Mayo Clinic

Mayo Clinic

Citations 11

Improved Visualization of Middle Ear Prostheses using Photon-Counting Detector CT: A Cadaver Study
Sadeghian, Maryam, Benson, John C. , Lane, John I. , Treb, Kevin , Khandalavala, Karl R. , Babajanian, Eric E. , Bruesewitz, Michael R. , Swicklik, Joseph R., Ou, Fang‐Shu , McCollough, Cynthia H, Carlson, Matthew L, Leng, Shuai, Ou, Fang-Shu , Sadeghian, Maryam , Farnsworth, Paul J. , McCollough, Cynthia H. , Carlson, Matthew L. , Leng, Shuai

Radiology Advances | September 14, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/radadv/umag041 Get It

Abstract Background Evaluation of middle ear prostheses requires high-resolution imaging to assess position and structural integrity. Purpose To assess the diagnostic performance of photon-counting-detector (PCD)-CT for middle ear prosthesis imaging in cadaveric specimens. Materials and Methods Nine different middle ear prostheses were implanted in five fresh-frozen whole-head specimens, both in correct anatomic position and displaced to mimic malposition. Specimens were scanned on PCD-CT (NAEOTOM Alpha, Siemens) and energy-integrating-detector (EID)-CT (SOMATOM Force, Siemens), reconstructed at 0.2mm and 0.4mm, respectively. Eighteen cases (9 prostheses, 2 positions) per scanner were evaluated by two neuroradiologists (36 readings), blinded to scanner and position, who scored prosthesis position, reader confidence, and overall image quality. Agreement with the reference standard and between readers was compared. Results PCD-CT showed higher diagnostic confidence compared with EID-CT, while accuracy and inter-reader agreement did not demonstrate significant differences between scanners. Correct readings, PCD-CT versus EID-CT: lateral contact, 31/36 (86.1%; 95% CI: 58.3%-94.4%) vs. 29/36 (80.6%; 55.6%-91.7%), p = 0.500; medial contact, 30/36 (83.3%; 55.6%-94.4%) vs. 26/36 (72.2%; 50.0%-83.3%), p = 0.250. PCD-CT identified all cases of complete contact loss (score 3), while EID-CT missed one reading per contact. Inter-reader agreement may be higher with PCD-CT vs EID-CT (lateral: κw: 0.804 [0.578-0.941] vs. 0.571 [0.302-0.778], p = 0.250; medial: 0.684 [0.191-0.934] vs. 0.481 [0.024-0.835], p = 0.250). Reader confidence was significantly higher with PCD-CT; mean paired differences for Readers 1 and 2 were 9.4 (1.8-17.1; Holm-adjusted p = 0.019) and 23.1 points (13.4-32.7; p < 0.001) for lateral contact, and 16.4 (10.0-22.8; p < 0.001) and 17.8 points (6.8-28.8; p = 0.007) for medial contact. Readers preferred PCD-CT image quality in 16/18 (88.9%; 65.3%-98.6%) and 17/18 cases (94.4%; 72.7%-99.9%), respectively. Conclusion PCD-CT was associated with significantly higher reader confidence and preferred image quality, without significant differences in diagnostic accuracy or inter-reader agreement. These findings suggest PCD-CT is a promising modality for postoperative middle ear evaluations that warrants further investigations.
Association of Radiologic Findings of Otosclerosis Using Photon-Counting Computed Tomography With Hearing
Babajanian, Eric E. , Swartz, Hayden J., Leng, Shuai, Lohse, Christine M. , Lane, Jack I., Carlson, Matthew L., Benson, John C. , Farnsworth, Paul J. , Swartz, Hayden J., Leng, Shuai , Carlson, Matthew L.

Otology & Neurotology | December 23, 2025 | Volume: 47 | Issue: 3 | Pages: 418-422

10.1097/mao.0000000000004798 Get It

Objective: To examine the association of extent of otosclerotic plaque using high-resolution photon-counting computed tomography (PCCT) with hearing and surgical outcomes. Study design: Historical cohort. Setting: Large academic center. Patients: Patients with otosclerosis who completed PCCT imaging at time of initial evaluation. Interventions: Observation, surgery. Main outcome measures: Audiometric data. Results: A total of 53 ears were eligible for study. The mean age at PCCT was 51 years (SD: 14). The mean extent of oval window otosclerotic plaque measured in radial degrees was 112 (SD: 65) and the mean otosclerotic depth was 1.6mm (SD: 0.6). The mean air-bone gap pure-tone average was 18 dB (SD: 12) and the mean Carhart degree was 9 dB (SD: 10). The radial degrees of oval window extent were not significantly associated with air-bone gap (correlation coefficient: 0.14; P =0.3) or Carhart degree (correlation coefficient: 0.04; P =0.8). Likewise, otosclerotic plaque depth was not significantly associated with air-bone gap (correlation coefficient: −0.19; P =0.2) or Carhart degree (correlation coefficient: −0.08; P =0.6). After PCCT, 22 ears underwent surgery. In this subset, oval window extent and plaque depth were not significantly associated with the postoperative changes in air-bone gap or high-frequency thresholds. Conclusions: Despite enhanced visualization of subtle abnormalities with PCCT imaging, the extent of oval window otosclerotic plaque, measured in angular degrees and depth, was not associated with hearing loss at time of initial evaluation or postoperative audiologic changes in patients with otosclerosis.
Loss of Enhancement in Vestibular Schwannomas Post Stereotactic Radiosurgery: Impact on Tumor Control and Serviceable Hearing
Mehta, Prav, Soni, Neetu , Lohse, Christine M. , Link, Michael J., Marinelli, John P. , Babajanian, Eric E. , Daher, Ghazal S. , Dornhoffer, Jim R., Khandalavala, Karl R. , Carlson, Matthew L. , Lane, John I. , Benson, John C. , Morshed, Ramin , Daher, Ghazal, Farnsworth, Paul J. , Mehta, Prav, Morshed, Ramin A. , Agarwal, Amit , Sonka, Milan , Link, Michael J. , Bathla, Girish

Otology & Neurotology | November 7, 2025 | Volume: 47 | Issue: 2 | Pages: e432-e438

10.1097/mao.0000000000004728 Get It

Objective: Vestibular schwannomas (VSs) treated with stereotactic radiosurgery (SRS) often show transient loss of central tumor enhancement. We hypothesized that this loss of enhancement may correlate with better tumor control on follow-up imaging. Methods: We evaluated 198 consecutive patients from a single center who met eligibility criteria. Tumor volumes on the pre-SRS and post-SRS scans were quantified along with regions of loss of enhancement on the first post-SRS study. The latter was correlated with tumor volumes at follow-up, radiation isocenter density, and loss of serviceable hearing. Results: For the entire cohort, the median loss of enhancement on the first post-SRS scan was 14% (IQR: 6 to 25) and median rate of change in tumor volume was −4.5% per year (IQR: −10.5 to 1.5). Percent loss of central enhancement showed significant negative correlation with tumor growth not only for the entire cohort (correlation coefficient: −0.18, P =0.01), but also for the subset of patients who had available imaging until at least 2 years (n=185) and 4 years (n=179) post-SRS. Loss of enhancement also strongly correlated positively with tumor volumes and number of radiation isocenters and negatively with isocenter density. Finally, patients with greater percent loss of enhancement had an increased likelihood of progression to non-serviceable hearing, although this association was not statistically significant. Conclusions: These findings suggest that loss of central tumor enhancement in VSs post-SRS may be associated with improved tumor control.
Aberrant ICA and Associated Skull Base Foramina Visualized on Photon Counting Detector CT: Interesting Images
Sadaney, Ahmed O El , Lane, John I. , El Sadaney, Ahmed O , Benson, John C. , Lane, John I , Farnsworth, Paul J. , Diehn, Felix E.

Diagnostics | September 1, 2025 | Volume: 15 | Issue: 17 | Pages: 2213

10.3390/diagnostics15172213 Get It

Aberrant internal carotid arteries (ICA) are congenital vascular anomalies that occur from involution of the cervical portion of the ICA, which leads to enlargement of the normally small collateral inferior tympanic and caroticotympanic arteries. The inferior tympanic artery is a branch of the external carotid artery, usually the ascending pharyngeal artery, which extends through the inferior tympanic canaliculus (ITC), a small foramen located along the cochlea promontory. Aberrant ICAs can also be associated with a persistent stapedial artery (PSA), which is an abnormal vessel that arises from the petrous ICA and passes through the obturator foramen of the stapes. An aberrant ICA is a very important anomaly to recognize on imaging. Accurately describing its presence is important to help prevent iatrogenic injury during intervention. It is also important to distinguish an aberrant ICA from a lateralized ICA. The improvement of spatial resolution with photon counting detector (PCD)-CT has been proven to provide higher performance in detection of sub-centimeter vascular lesions compared to conventional energy-integrated detector (EID)-CT. PCD-CT also provides superior visualization of small skull-based foramina such as the inferior tympanic canaliculus, which can aid in more accurately characterizing an aberrant ICA (variant course without ITC involvement).
The rarely described association between pseudoaneurysm and aberrant ICA: A case series
Yousif, Paul , Farnsworth, Paul J. , Carlson, Matthew L. , Welker, Kirk M. , Bathla, Girish , Sadaney, Ahmed O El , Lane, Jack I., Farnsworth, Paul , Carlson, Matthew, Welker, Kirk, Guerin, Julie, Bathla, Girish , El Sadaney, Ahmed O , Lane, Jack, Guérin, J.

Interventional Neuroradiology | July 7, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251353316 Get It

Aberrant internal carotid artery (ICA) is a vascular anomaly in which a segment of the ICA courses through the middle ear. The association of aberrant ICAs and pseudoaneurysm formation is not well known and can be an important finding to recognize on imaging. In this series, we present three cases of aberrant ICAs having asymmetric contour deformities consistent with pseudoaneurysms diagnosed utilizing CT of the temporal bone.
Dynamic Optic Nerve MRI Changes in Acute Optic Neuritis in MOG Antibody-Associated Disease (P11-8.006)
Tajfirouz, Deena , Chodnicki, Kevin D. , Bhatti, M. Tariq , Tillema, Jan-Mendelt , Syc‐Mazurek, Stephanie B. , Cacciaguerra, Laura , Farnsworth, Paul J. , Tillema, Jan‐Mendelt , Pittock, Sean J. , Flanagan, Eoin P. , Chen, John J.

Neurology | April 7, 2025 | Volume: 104 | Issue: 7_Supplement_1 | Pages: No page available

10.1212/wnl.0000000000211231 Get It

Improved visualization of cochlear implant electrodes on photon counting detector CT
Schroeder, Dane G. , Farnsworth, Paul J. , Benson, John C. , Carlson, Matthew L. , Kassmeyer, Blake , Lane, Jack I., Benson, John , Farnsworth, Paul , Carr, Carrie M. , DeLone, David R. , Leng, Shuai , Mark, Ian T.

Clinical Neuroimaging | October 25, 2024 | Volume: 1 | Issue: 1-2 | Pages: No page available

10.1002/neo2.70005 Get It

AbstractBackgroundCochlear implants (CIs) are used to rehabilitate moderate to profound sensorineural hearing loss and stimulate the auditory system via a multichannel electrode array positioned in the scala tympani. Imaging evaluation of CIs is substantially degraded by metallic artifacts. Photon‐counting detector (PCD)‐CT has the potential to minimize such artifacts, though this has not been convincingly established in prior studies. This study compared the visualization of CI electrodes on PCD‐CT to conventional energy integrating detector (EID)‐CT.Materials and MethodsFive patients with CIs were prospectively recruited to undergo temporal bone imaging on both EID‐CT and PCD‐CT scanners yielding 2D and 3D Volume Rendering Technique (VRT) images. Three nonblinded neuroradiologists reviewed 2D and 3D VRT images for the ability to resolve CI electrode leads using a Likert scale. The average Likert scores of PCD‐CT versus EID‐CT were calculated for each reader for both 2D and 3D VRT images. (Likert scores 1–5 based on inferior to superior rating of PCD‐CT compared to EID‐CT). Inter‐rater agreement was assessed using Krippendorff's alpha with ordinal weights. ResultsFive patients underwent temporal bone CT for CI array evaluation. As evidenced by 5‐point Likert scales that were independently used by the three reviewers, this study demonstrated superior resolution of CI electrode array using PCD‐CT as compared to EID‐CT with an average score of 4.2 ± 0.8 for 2D images and 4.9 ± 0.4 for 3D VRT images.ConclusionsPCD‐CT is superior to EID‐CT in the visualization of CI electrodes, particularly in 3D VRT imaging.
Improved visualization of the chorda tympani with photon counting detector CT
Joseph, Annie K. , Farnsworth, Paul J. , Carlson, Matthew L. , Benson, John C. , Madhavan, Ajay A. , Lane, John I. , Benson, John , Madhavan, Ajay A , Farnsworth, Paul , Campeau, Norbert G. , Leng, Shuai

Clinical Neuroimaging | August 17, 2024 | Volume: 1 | Issue: 1-2 | Pages: No page available

10.1002/neo2.18 Get It

AbstractBackground and PurposeTo compare the performance of the photon‐counting detector (PCD)‐CT against a cutting‐edge energy‐integrated detector (EID)‐CT to visualize different segments of the chorda tympani nerve.Materials and MethodsAn IRB‐approved protocol prospectively enrolled patients for temporal bone CT on both EID‐CT and PCD‐CT scanners. Fellowship‐trained neuroradiologists compared visualization of chorda tympani segments on each scanner using a 5‐point Likert scale (1 indicating EID is far superior to PCD, 3 indicating they are equivalent, and 5 indicating PCD is far superior to EID). Scores were averaged across segments and tested using a one‐sample Wilcoxon signed‐rank test with a one‐sided alternative hypothesis.ResultsForty temporal bones were evaluated. Average Likert scores for visualization of chorda tympani segments‐chorda tympani canal/proximal segment, middle ear/posterior tympanic segment, and petrotympanic fissure/distal segment‐ on the PCD compared to EID scanner were 4.2 (SD = 0.4), 4.4 (0.5), and 4 (0.0), respectively. The anterior tympanic segment of the chorda tympani was not well visualized on either platform or therefore not scored. PCD compared to the EID scanner had better overall performance (Median = 4.2, 95% CI: [4.1, 5.0], p‐value < .001).ConclusionPCD‐CT improves visualization of the petrous and intratympanic chorda tympani nerve segments, chorda tympani canaliculus, and petrotympanic fissure compared to comparable EID‐CT examinations. The improved visualization of the chorda tympani is important for the characterization of middle ear pathology involving this structure and presurgical planning to determine the size of the facial recess for cochlear implantation and to estimate the risk of nerve injury.
High-resolution computed tomography angiography of the orbit using a photon-counting computed tomography scanner
Farnsworth, Paul J. , Yu, Lifeng , Leng, Shuai , Zhou, Zhongxing , Diehn, Felix E. , Leng, Shuai , Farnsworth, Paul , Campeau, Norbert G. , Yu, Lifeng , Fletcher, Joel G. , McCollough, Cynthia H.

Interventional Neuroradiology | July 4, 2023 | Volume: 31 | Issue: 4 | Pages: 539-554

10.1177/15910199231175198 Get It

Background and Purpose Recent introduction of photon counting detector (PCD) computed tomography (CT) scanners into clinical practice further improve CT angiography (CTA) depiction of orbital arterial vasculature compared to conventional energy integrating detector (EID) CT scanners. PCD-CTA of the orbit can provide a detailed arterial roadmap of the orbit which can de diagnostic on its own or serve as a helpful planning adjunct for both diagnostic and therapeutic catheter-based angiography of the orbit. Methods For this review, EID and PCD-CT imaging was obtained in 28 volunteers. The volume CT dose index was closely matched. A dual-energy scanning protocol was used on EID-CT. An ultra-high-resolution (UHR) scan mode was used on PCD-CT. Images were reconstructed at 0.6 mm slice thickness using a closely matched medium-sharp standard resolution (SR) kernel. High-resolution (HR) images with the sharpest quantitative kernel were also reconstructed on PCD-CT at the thinnest slice thickness of 0.2 mm. A denoising algorithm was applied to the HR image series. Results The imaging description of the orbital vascular anatomy presented in this work was derived from these patients’ PCD-CTA images in combination with review of the literature. We found that orbital arterial anatomy is much better depicted with PCD-CTA, and this work can serve primarily as an imaging atlas of the normal orbital vascular anatomy. Conclusion With recent advances in technology, arterial anatomy of the orbit is much better depicted with PCD-CTA as opposed to EID-CTA. Current orbital PCD-CTA technology approaches the necessary resolution threshold for reliable evaluation of central retinal artery occlusion.