Schroeder, Dane G. , Farnsworth, Paul J. , Benson, John C. , Carlson, Matthew L. , Kassmeyer, Blake , Lane, Jack I., Benson, John , Farnsworth, Paul , Carr, Carrie M. , DeLone, David R. , Leng, Shuai , Mark, Ian T.

Clinical Neuroimaging | October 25, 2024 | Volume: 1 | Issue: 1-2 | Pages: No page available

10.1002/neo2.70005 Get It

AbstractBackgroundCochlear implants (CIs) are used to rehabilitate moderate to profound sensorineural hearing loss and stimulate the auditory system via a multichannel electrode array positioned in the scala tympani. Imaging evaluation of CIs is substantially degraded by metallic artifacts. Photon‐counting detector (PCD)‐CT has the potential to minimize such artifacts, though this has not been convincingly established in prior studies. This study compared the visualization of CI electrodes on PCD‐CT to conventional energy integrating detector (EID)‐CT.Materials and MethodsFive patients with CIs were prospectively recruited to undergo temporal bone imaging on both EID‐CT and PCD‐CT scanners yielding 2D and 3D Volume Rendering Technique (VRT) images. Three nonblinded neuroradiologists reviewed 2D and 3D VRT images for the ability to resolve CI electrode leads using a Likert scale. The average Likert scores of PCD‐CT versus EID‐CT were calculated for each reader for both 2D and 3D VRT images. (Likert scores 1–5 based on inferior to superior rating of PCD‐CT compared to EID‐CT). Inter‐rater agreement was assessed using Krippendorff's alpha with ordinal weights. ResultsFive patients underwent temporal bone CT for CI array evaluation. As evidenced by 5‐point Likert scales that were independently used by the three reviewers, this study demonstrated superior resolution of CI electrode array using PCD‐CT as compared to EID‐CT with an average score of 4.2 ± 0.8 for 2D images and 4.9 ± 0.4 for 3D VRT images.ConclusionsPCD‐CT is superior to EID‐CT in the visualization of CI electrodes, particularly in 3D VRT imaging.
Frequency and Characteristics of Nodal and Deltoid FDG and 11C-Choline Uptake on PET Performed After COVID-19 Vaccination
Schroeder, Dane G. , Jang, Samuel , Takahashi, Hiroaki , Navin, Patrick J. , Thorpe, Matthew , Johnson, Geoffrey B. , Thorpe, Matthew P, Johnson, Geoffrey B , Navin, Patrick , Johnson, Derek R. , Broski, Stephen M. , Young, Jason R. , Takahashi, Hiroaki

American Journal of Roentgenology | May 19, 2021 | Volume: 217 | Issue: 5 | Pages: 1206-1216

10.2214/ajr.21.25928 Get It