Objective: To explore the existing evidence on novel imaging modalities that may aid in prognostication of vestibular schwannoma (VS) clinical outcomes across various management approaches. Study design: Scoping review. Setting: Not applicable. Patients: Individuals diagnosed with VS. Interventions: Novel imaging techniques. Main outcome measures: Tumor growth and response to medical therapy. Results: A total of 18 articles were included in this review. Of these, 7 focused on pretreatment prognosis, 6 evaluated radiosurgery outcomes, 4 examined microsurgery outcomes, and 1 assessed response to bevacizumab. The imaging modalities investigated included radiomics (n = 10), positron emission tomography (PET; n = 2), dynamic contrast-enhanced MRI (DCE-MRI; n = 2), both PET and DCE-MRI (n = 1), magnetic resonance elastography (MRE; n = 1), contrast-enhanced CT (CE-CT; n = 1), and slip interface imaging (SII; n = 1). Radiomic studies yielded encouraging results in predicting tumor growth after wait-and-scan and radiosurgery, with reported accuracies ranging from 52% to 88%, sensitivities from 13% to 95%, specificities from 50% to 94%, and area under the curves from 0.65 to 0.99. PET studies identified several promising ligands associated with tumor growth during wait-and-scan, suggesting a potential role in prognostication. DCE-MRI also demonstrated associations with tumor growth and treatment response to bevacizumab. Studies on MRE, CE-CT, and SII identified novel imaging parameters associated with tumor stiffness and adhesion. Conclusions: Several emerging imaging modalities hold potential for improving clinical outcome prognostication in VS. Techniques such as radiomics, PET, and DCE-MRI have shown promising results; however, the supporting evidence is still limited and heterogeneous. Further research is necessary to validate and refine these approaches to enhance their clinical utility.
Association of Radiologic Findings of Otosclerosis Using Photon-Counting Computed Tomography With Hearing
Objective: To examine the association of extent of otosclerotic plaque using high-resolution photon-counting computed tomography (PCCT) with hearing and surgical outcomes. Study design: Historical cohort. Setting: Large academic center. Patients: Patients with otosclerosis who completed PCCT imaging at time of initial evaluation. Interventions: Observation, surgery. Main outcome measures: Audiometric data. Results: A total of 53 ears were eligible for study. The mean age at PCCT was 51 years (SD: 14). The mean extent of oval window otosclerotic plaque measured in radial degrees was 112 (SD: 65) and the mean otosclerotic depth was 1.6mm (SD: 0.6). The mean air-bone gap pure-tone average was 18 dB (SD: 12) and the mean Carhart degree was 9 dB (SD: 10). The radial degrees of oval window extent were not significantly associated with air-bone gap (correlation coefficient: 0.14; P =0.3) or Carhart degree (correlation coefficient: 0.04; P =0.8). Likewise, otosclerotic plaque depth was not significantly associated with air-bone gap (correlation coefficient: −0.19; P =0.2) or Carhart degree (correlation coefficient: −0.08; P =0.6). After PCCT, 22 ears underwent surgery. In this subset, oval window extent and plaque depth were not significantly associated with the postoperative changes in air-bone gap or high-frequency thresholds. Conclusions: Despite enhanced visualization of subtle abnormalities with PCCT imaging, the extent of oval window otosclerotic plaque, measured in angular degrees and depth, was not associated with hearing loss at time of initial evaluation or postoperative audiologic changes in patients with otosclerosis.
The rarely described association between pseudoaneurysm and aberrant ICA: A case series
Aberrant internal carotid artery (ICA) is a vascular anomaly in which a segment of the ICA courses through the middle ear. The association of aberrant ICAs and pseudoaneurysm formation is not well known and can be an important finding to recognize on imaging. In this series, we present three cases of aberrant ICAs having asymmetric contour deformities consistent with pseudoaneurysms diagnosed utilizing CT of the temporal bone.
Improved visualization of cochlear implant electrodes on photon counting detector CT
AbstractBackgroundCochlear implants (CIs) are used to rehabilitate moderate to profound sensorineural hearing loss and stimulate the auditory system via a multichannel electrode array positioned in the scala tympani. Imaging evaluation of CIs is substantially degraded by metallic artifacts. Photon‐counting detector (PCD)‐CT has the potential to minimize such artifacts, though this has not been convincingly established in prior studies. This study compared the visualization of CI electrodes on PCD‐CT to conventional energy integrating detector (EID)‐CT.Materials and MethodsFive patients with CIs were prospectively recruited to undergo temporal bone imaging on both EID‐CT and PCD‐CT scanners yielding 2D and 3D Volume Rendering Technique (VRT) images. Three nonblinded neuroradiologists reviewed 2D and 3D VRT images for the ability to resolve CI electrode leads using a Likert scale. The average Likert scores of PCD‐CT versus EID‐CT were calculated for each reader for both 2D and 3D VRT images. (Likert scores 1–5 based on inferior to superior rating of PCD‐CT compared to EID‐CT). Inter‐rater agreement was assessed using Krippendorff's alpha with ordinal weights. ResultsFive patients underwent temporal bone CT for CI array evaluation. As evidenced by 5‐point Likert scales that were independently used by the three reviewers, this study demonstrated superior resolution of CI electrode array using PCD‐CT as compared to EID‐CT with an average score of 4.2 ± 0.8 for 2D images and 4.9 ± 0.4 for 3D VRT images.ConclusionsPCD‐CT is superior to EID‐CT in the visualization of CI electrodes, particularly in 3D VRT imaging.
Withdrawal of bevacizumab is associated with rebound growth of vestibular schwannomas in neurofibromatosis type 2-related schwannomatosis patients
Abstract Background Neurofibromatosis type 2 (NF2)-related schwannomatosis is an autosomal dominant tumor-predisposition syndrome characterized by bilateral vestibular schwannomas (VS). In patients with VS associated with NF2, vascular endothelial growth factor A inhibitor, bevacizumab, is a systemic treatment option. The aim of this study is to retrospectively evaluate NF2 patient responses to bevacizumab on VS growth and symptom progression. Methods This is a retrospective analysis of patients seen at the Mayo Clinic Rochester Multidisciplinary NF2 Clinic. Results Out of 76 patients with NF2 evaluated between 2020 and 2022, we identified 19 that received treatment with bevacizumab. Thirteen of these patients discontinued bevacizumab after median treatment duration of 12.2 months. The remaining 6 patients are currently receiving bevacizumab treatment for a median duration of 9.4 months as of March, 2023. Fifteen patients had evaluable brain MRI data, which demonstrated partial responses in 5 patients, stable disease in 8, and progression in 2. Within 6 months of bevacizumab discontinuation, 5 patients had rebound growth of their VS greater than 20% from their previous tumor volume, while 3 did not. Three patients with rebound growth went on to have surgery or irradiation for VS management. Conclusions Our single-institution experience confirms prior studies that bevacizumab can control progression of VS and symptoms associated with VS growth. However, we note that there is the potential for rapid VS growth following bevacizumab discontinuation, for which we propose heightened surveillance imaging and symptom monitoring for at least 6 months upon stopping anti-VEGF therapy.