Back to Authors

Takahashi, Hiroaki

https://orcid.org/0000-0002-8731-0081

Mayo Clinic

Mayo Clinic

Citations 14

Artificial Intelligence‐Estimated Intrapancreatic Fat and Its Relationship to Familial and Germline Pancreatic Cancer Risk
Konikoff, Tom , Takahashi, Hiroaki , Suman, Garima , Mishra, Anup Kumar , Korfiatis, Panos, Carlson, Erin E., Bamlet, William R., Pradeep, Aishwarya , Harper, Kelly, Delgado, Adriana, Goenka, Ajit H. , Oberg, Ann L. , Takahashi, Hiroaki , Nugen, Fred , Mishra, Anup , Pradeep, Aishwarya , Doering, Karen A , Erickson, Bradley J , Goenka, Ajit Harishkumar , Takahashi, Naoki , Oberg, Ann L , Majumder, Shounak , Janssens, Laurens , Nugen, Fred , Carlson, Erin E., Bamlet, William R. , Doering, Karen A. , Delgado, Adriana, Erickson, Bradley J. , Takahashi, Naoki , Majumder, Shounak

United European Gastroenterology Journal | August 29, 2026 | Volume: 14 | Issue: 7 | Pages: No page available

10.1002/ueg2.70279 Get It

ABSTRACT Background Family history of pancreatic cancer (PC), pathogenic germline variants (PGVs), and increased intrapancreatic fat (IPF) are individually associated with increased PC risk. Whether IPF is elevated in high‐risk individuals (HRIs) with PC family history or PGVs is unknown. Although MRI is the preferred modality for IPF measurement, region‐of‐interest–based approaches are prone to sampling bias because pancreatic fat is heterogeneously distributed. We aimed to compare IPF among HRIs and matched non‐HRI controls using an Artificial intelligence (AI)‐based tool for whole pancreatic IPF measurement applied to magnetic resonance imaging (MRI). Methods We developed and validated a deep‐learning pipeline for IPF measurement that incorporates automated pancreas segmentation on T1‐weighted MRI images registered to the corresponding iterative decomposition of water and fat with echo asymmetry and least squares estimation images to compute IPF using proton density fat fraction (PDFF). This pipeline was used to quantify IPF and assess IPF distribution patterns in 85 HRIs and 170 non‐HRIs matched 1:2 for age, sex, BMI, and diabetes status. A surface erosion approach was developed to minimize the impact of peripancreatic fat on IPF measurement. Linear models adjusting for matching variables were used to assess associations. Results Model‐expert agreement for whole‐pancreas PDFF was excellent (intraclass correlation coefficient 0.99; 95% CI, 0.98–0.99 mean absolute error 1.4%). Mean PDFF did not differ between HRIs and controls (25.8% [11.5] vs. 26.9% [11.4]; p = 0.32). PDFF increased with age ( p = 0.015), male sex ( p < 0.001), presence of diabetes ( p = 0.009), BMI ( p < 0.001). IPF distribution patterns did not differ by risk group. Conclusion An AI‐based approach provides accurate, scalable, and objective assessment of IPF quantity and distribution. IPF quantity and spatial distribution do not appear to differ based on germline or familial predisposition to PC.
Imaging of Complications after Prostate Interventions
Thompson, Cole P. , Takahashi, Hiroaki , Broski, S. M., Froemming, Adam T. , Takahashi, Naoki , Woodrum, David A. , Andrews, Jack R. , Kawashima, Akira , Kawashima, Akira , Thompson, Cole P. , Takahashi, Naoki , Takahashi, Hiroaki , Broski, Stephen M.

RadioGraphics | July 16, 2026 | Volume: 46 | Issue: 8 | Pages: No page available

10.1148/rg.250116 Get It

Imaging is integral to detection and characterization of complications after prostate interventions, including vascular, infectious, urinary, and radiation-related complications, and facilitates timely diagnosis and management.
Prostate Cancer Risk Prediction Model Using Clinical and Magnetic Resonance Imaging–Related Findings: Impact of Combining Lesions’ Locations and Apparent Diffusion Coefficient Values
Froemming, Adam T. , Klug, Jason R., Korfiatis, Panagiotis , Lomas, Derek J. , Humphreys, Mitchell R. , Takahashi, Naoki , Takahashi, Hiroaki , Nakai, Hirotsugu , LeGout, Jordan D. , Dora, Chandler , Takahashi, Naoki , Takahashi, Hiroaki , Takahashi, Hiroaki , Kawashima, Akira

Journal of Computer Assisted Tomography | November 14, 2024 | Volume: 49 | Issue: 2 | Pages: 247-257

10.1097/rct.0000000000001679 Get It

Objectives: The aims of the study are to develop a prostate cancer risk prediction model that combines clinical and magnetic resonance imaging (MRI)–related findings and to assess the impact of adding Prostate Imaging-Reporting and Data System (PI-RADS) ≥3 lesions-level findings on its diagnostic performance. Methods: This 3-center retrospective study included prostate MRI examinations performed with clinical suspicion of clinically significant prostate cancer (csPCa) between 2018 and 2022. Pathological diagnosis within 1 year after the MRI was used to diagnose csPCa. Seven clinical, 3 patient-level MRI-related, and 4 lesion-level MRI-related findings were extracted. After feature selection, 2 logistic regression models with and without lesions-level findings were created using data from facility I and II (development cohort). The area under the receiver operating characteristic curve (AUC) between the 2 models was compared in the PI-RADS ≥3 population in the development cohort and Facility III (validation cohort) using the Delong test. Interfacility differences of the selected predictive variables were evaluated using the Kruskal-Wallis test or chi-squared test. Results: Selected lesion-level features included the peripheral zone involvement and apparent diffusion coefficient (ADC) values. The model with lesions-level findings had significantly higher AUC than the model without in 655 examinations in the development cohort (0.81 vs 0.79, respectively, P = 0.005), but not in 553 examinations in the validation cohort (0.77 vs 0.76, respectively). Large interfacility differences were seen in the ADC distribution (P < 0.001) and csPCa proportion in PI-RADS 3–5 (P < 0.001). Conclusions: Adding lesions-level findings improved the csPCa discrimination in the development but not the validation cohort. Interfacility differences impeded model generalization, including the distribution of reported ADC values and PI-RADS score-level csPCa proportion.
Imaging of Upper Tract Urothelial Carcinoma
Nakai, Hirotsugu , Takahashi, Hiroaki , Wellnitz, Clinton V., Stanton, Melissa, Takahashi, Naoki , Kawashima, Akira , Stanton, Melissa L, Kawashima, Akira , Takahashi, Naoki , Takahashi, Hiroaki

RadioGraphics | October 31, 2024 | Volume: 44 | Issue: 11 | Pages: No page available

10.1148/rg.240056 Get It

Multifaceted risk stratification is required for management of upper tract urothelial carcinoma, and imaging plays an important integrated role in diagnosis and management.
Fully Automated Deep Learning Model to Detect Clinically Significant Prostate Cancer at MRI
Cai, Jason , Nakai, Hirotsugu , Kuanar, Shiba , Froemming, Adam T. , Bolan, Candice W. , Kawashima, Akira , Takahashi, Hiroaki , Mynderse, Lance A. , Humphreys, Mitchell R. , Korfiatis, Panagiotis , Bratt, Alex , Takahashi, Naoki , Dora, Chandler D , Humphreys, Mitchell R , Korffiatis, Panagiotis , Rouzrokh, Pouria , Bratt, Alex , Conte, Gian Marco , Erickson, Bradley J , Takahashi, Naoki , Kawashima, Akira , Takahashi, Hiroaki , Dora, Chandler , Rouzrokh, Pouria , Erickson, Bradley J.

Radiology | August 6, 2024 | Volume: 312 | Issue: 2 | Pages: No page available

10.1148/radiol.232635 Get It

The performance of a deep learning model was not different from that of radiologists in the detection of clinically significant prostate cancer at MRI, and gradient-weighted class activation maps localized the tumor.
Accuracy of DOTATATE PET imaging in the preoperative planning of small bowel neuroendocrine tumor resection
Zhang, Chi , Gudmundsdottir, Hallbera , Takahashi, Hiroaki , Day, Courtney N. , Glasgow, Amy E. , Wasif, Nabil , Grotz, Travis E. , Smoot, Rory L. , Truty, Mark J. , Kendrick, Michael L. , Nagorney, David M. , Grotz, Travis E , Truty, Mark, Cleary, Sean, Kendrick, Michael, Nagorney, David, Navin, Patrick, Thiels, Cornelius A , Smoot, Rory L , Gudmundsdottir, Hallbera , Takahashi, Hiroaki , Starlinger, Patrick , Warner, Susanne G. , Cleary, Sean P. , Navin, Patrick J. , Hálfdánarson, Þorvarður R. , Thiels, Cornelius A.

Journal of Surgical Oncology | August 2, 2023 | Volume: 128 | Issue: 7 | Pages: 1072-1079

10.1002/jso.27413 Get It

AbstractBackground and ObjectivesWe assessed the accuracy of preoperative gallium‐68 DOTA‐Tyr3‐octreotate (DOTATATE) positron emission tomography (PET) imaging in estimating multifocality and nodal metastases of small bowel neuroendocrine tumors (sbNETs).MethodsA multicenter analysis was performed on patients with sbNETs who underwent preoperative DOTATATE PET imaging and surgical resection, with manual palpation of the entire length of the small bowel, between January 2016 and August 2022. Preoperative imaging reports and blinded secondary imaging reviews were compared to the final postoperative pathology reports. Descriptive statistics were applied.ResultsOne‐hundred and four patients met inclusion criteria. Pathology showed 53 (51%) patients had multifocal sbNETs and 96 (92%) had nodal metastases. The original preoperative DOTATATE PET imaging identified multifocal sbNET in 28 (27%) patients and lymph node (LN) metastases in 80 (77%) patients. Based on original radiology reports, sensitivity for multifocal sbNET identification was 45%, specificity was 92%, positive predictive value (PPV) was 86%, and negative predictive value (NPV) was 62%. For the identification of LN metastases, sensitivity was 82%, specificity was 88%, PPV was 99%, and NPV was 29%.ConclusionsAlthough DOTATATE PET imaging is specific and relatively accurate, sensitivity and NPV are insufficient to guide surgical planning. Preoperative use should not replace open palpation to identify additional synchronous lesions or to omit regional lymphadenectomy.
Imaging of the Bulbourethral (Cowper) Gland: Abnormalities and Differential Diagnosis
Takahashi, Hiroaki , Potretzke, Theodora A. , Kawashima, Akira , Cheville, John C. , Masuoka, Sota , Kawashima, Akira , Potretzke, Theodora , Takahashi, Hiroaki , Kim, Bohyun

RadioGraphics | September 23, 2022 | Volume: 42 | Issue: 7 | Pages: 2037-2053

10.1148/rg.220099 Get It

Diagnostic Performance in Low- and High-Contrast Tasks of an Image-Based Denoising Algorithm Applied to Radiation Dose–Reduced Multiphase Abdominal CT Examinations
Voß, Benjamin, Lee, Nam Ju, Takahashi, Hiroaki , Kozaka, Kazuto , Heiken, Jay P. , Ehman, Eric C. , Vasconcelos, Rogerio N., Fidler, Jeff L. , Lee, Yong S. , Mileto, Achille , Johnson, Matthew P. , Baer‐Beck, Matthias, Weber, Nikkole M. , Michalak, Gregory J. , Halaweish, Ahmed F., Carter, Rickey E. , Inoue, Akitoshi , Voss, Benjamin A, Vasconcelos, Rogerio, Halaweish, Ahmed, Carter, Rickey E , Takahashi, Hiroaki , Lee, Nam Ju, Fidler, Jeff L. , McCollough, Cynthia H. , Fletcher, Joel G.

American Journal of Roentgenology | June 22, 2022 | Volume: 220 | Issue: 1 | Pages: 73-85

10.2214/ajr.22.27806 Get It

Application of the advanced lung cancer inflammation index for patients with coronavirus disease 2019 pneumonia: Combined risk prediction model with lung cancer inflammation index, computed tomography and chest radiograph
Takahashi, Hiroaki , Ibe, Tatsuya, Ishii, Hisashi, Kurata, Yuhei, Ishizuka, Yoshikazu, Batsaikhan, Bolorkhand, Hamamoto, Yoichiro , Inoue, Akitoshi , Takahashi, Hiroaki , Ishii, Hisashi, Ishizuka, Yoshikazu

Experimental and Therapeutic Medicine | April 12, 2022 | Volume: 23 | Issue: 6 | Pages: No page available

10.3892/etm.2022.11315 Get It

An interactive eye‐tracking system for measuring radiologists' visual fixations in volumetric CT images: Implementation and initial eye‐tracking accuracy validation
Gong, Hao , Hsieh, Scott S. , Holmes, David R. , Cook, David A. , Bartlett, David J. , Baffour, Francis , Takahashi, Hiroaki , Yu, Lifeng , Inoue, Akitoshi , Baffour, Francis I , Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H. , Fletcher, Joel G. , Takahashi, Hiroaki

Medical Physics | September 17, 2021 | Volume: 48 | Issue: 11 | Pages: 6710-6723

10.1002/mp.15219 Get It

AbstractPurposeEye‐tracking approaches have been used to understand the visual search process in radiology. However, previous eye‐tracking work in computer tomography (CT) has been limited largely to single cross‐sectional images or video playback of the reconstructed volume, which do not accurately reflect radiologists' visual search activities and their interactivity with three‐dimensional image data at a computer workstation (e.g., scroll, pan, and zoom) for visual evaluation of diagnostic imaging targets. We have developed a platform that integrates eye‐tracking hardware with in‐house‐developed reader workstation software to allow monitoring of the visual search process and reader‐image interactions in clinically relevant reader tasks. The purpose of this work is to validate the spatial accuracy of eye‐tracking data using this platform for different eye‐tracking data acquisition modes.MethodsAn eye‐tracker was integrated with a previously developed workstation designed for reader performance studies. The integrated system captured real‐time eye movement and workstation events at 1000 Hz sampling frequency. The eye‐tracker was operated either in head‐stabilized mode or in free‐movement mode. In head‐stabilized mode, the reader positioned their head on a manufacturer‐provided chinrest. In free‐movement mode, a biofeedback tool emitted an audio cue when the head position was outside the data collection range (general biofeedback) or outside a narrower range of positions near the calibration position (strict biofeedback). Four radiologists and one resident were invited to participate in three studies to determine eye‐tracking spatial accuracy under three constraint conditions: head‐stabilized mode (i.e., with use of a chin rest), free movement with general biofeedback, and free movement with strict biofeedback. Study 1 evaluated the impact of head stabilization versus general or strict biofeedback using a cross‐hair target prior to the integration of the eye‐tracker with the image viewing workstation. In Study 2, after integration of the eye‐tracker and reader workstation, readers were asked to fixate on targets that were randomly distributed within a volumetric digital phantom. In Study 3, readers used the integrated system to scroll through volumetric patient CT angiographic images while fixating on the centerline of designated blood vessels (from the left coronary artery to dorsalis pedis artery). Spatial accuracy was quantified as the offset between the center of the intended target and the detected fixation using units of image pixels and the degree of visual angle.ResultsThe three head position constraint conditions yielded comparable accuracy in the studies using digital phantoms. For Study 1 involving the digital crosshairs, the median ± the standard deviation of offset values among readers were 15.2 ± 7.0 image pixels with the chinrest, 14.2 ± 3.6 image pixels with strict biofeedback, and 19.1 ± 6.5 image pixels with general biofeedback. For Study 2 using the random dot phantom, the median ± standard deviation offset values were 16.7 ± 28.8 pixels with use of a chinrest, 16.5 ± 24.6 pixels using strict biofeedback, and 18.0 ± 22.4 pixels using general biofeedback, which translated to a visual angle of about 0.8° for all three conditions. We found no obvious association between eye‐tracking accuracy and target size or view time. In Study 3 viewing patient images, use of the chinrest and strict biofeedback demonstrated comparable accuracy, while the use of general biofeedback demonstrated a slightly worse accuracy. The median ± standard deviation of offset values were 14.8 ± 11.4 pixels with use of a chinrest, 21.0 ± 16.2 pixels using strict biofeedback, and 29.7 ± 20.9 image pixels using general biofeedback. These corresponded to visual angles ranging from 0.7° to 1.3°.ConclusionsAn integrated eye‐tracker system to assess reader eye movement and interactive viewing in relation to imaging targets demonstrated reasonable spatial accuracy for assessment of visual fixation. The head‐free movement condition with audio biofeedback performed similarly to head‐stabilized mode.