Abstract Dysphagia is defined as a subjective sensation of difficulty swallowing and can result from oropharyngeal or esophageal etiologies based upon patient symptoms. Dysphagia affects approximately 16% of adults in the general population, with prevalence increasing with age. Esophagogastroduodenuoscopy (EGD) is initially performed to assess for structural abnormalities resulting in esophageal dysphagia. However, if EGD reveals no pathologic abnormalities, high-resolution manometry (HRM) and barium esophagography are performed in order to assess for underlying causes of dysmotility. Esophageal motility disorders (EMDs) are an underrecognized cause of dysphagia and can be characterized by impaired esophageal peristalsis or lower esophageal sphincter dysfunction. High-resolution manometry (HRM) measures key metrics such as integrated relaxation pressure (IRP), which is the deglutitive relaxation across the LES, and metrics of esophageal body peristalsis based on distal contractile integral (DCI) and distal latency (DL). The Chicago Classification version 4 (CCv4.0), published in 2021, provides a standardized classification scheme for differentiating EMDs using metrics from HRM. Additionally, barium esophagography has remained an important adjunctive diagnostic modality, as this may identify strictures, neoplasms, or hiatal hernias, but can also identify major motility disorders such as achalasia and distal esophageal spasm. The combined use of HRM with timed barium esophagram can enhance the diagnostic accuracy of EMDs, particularly when HRM demonstrates inconclusive findings. Therefore, radiologists should be familiar with how imaging findings from barium esophagram integrate with findings noted on HRM. The aim of this review is to highlight the findings of EMDs noted on HRM in conjunction with barium esophagography, thereby illustrating characteristic patterns of primary and secondary EMDs.
A Pilot Validation Study of Plant‐Based and Allergy‐Friendly Alternative for Testing Gastric Emptying: A Randomized Trial in Healthy Participants
ABSTRACT Background Gastric emptying (GE) scintigraphy with 4‐h imaging and a radiolabeled chicken egg‐based meal (320 kcal, 30% fat) is the standard test for gastroparesis at Mayo Clinic, with an intraindividual coefficient of variation (COV intra ) of 23.8% for GE half emptying time (T 1/2 ). Alternative meals for patients with dietary restrictions, including egg allergies or vegan diets, are lacking, limiting test accessibility. The study aimed to establish a vegan, lactose‐, nut‐, and gluten‐free meal with similar caloric and fat content to the egg meal and to assess its performance in GE studies. Methods In Vitro: 99m Tc binding to egg meal over 4 h was compared to a calorically and nutritionally similar vegan alternative, JUST Egg, using a validated in vitro model simulating gastric conditions of pH, pepsin, and stirring. In Vivo: 10 healthy participants underwent randomized crossover GE scintigraphy with standard and vegan meals, spaced ≥ 3 days apart to measure GE% at 2 h, 4 h, and GE T 1/2 . Group comparisons and variance analysis included Rank Sum tests and Bland–Altman plots. Key Results In Vitro: A strong correlation ( R = 0.975, p ‐value < 0.01) between 99m Tc binding in the egg and vegan egg models was observed. Minimal variance (< 10%) was recorded at all time points. In Vivo: GE at 4 h and GE T 1/2 showed non‐statistically significant mean differences, < 2% and < 10 min respectively, between both meals. The intra‐individual variability was 18.8%. Conclusions and Inferences The vegan meal demonstrated in vitro stability, in vivo performance comparable to the egg meal, and a COV intra of 18.8%, which was lower than the 23.8% reported in repeat egg meal GE studies. Trial Registration ClinicalTrials.gov number NCT06991036 ( https://clinicaltrials.gov/study/NCT06991036?term=NCT06991036&rank=1 )
When a Pancreatic Mass Is Not Malignant: A Case of Pancreatic Splenosis
Abstract Background We aimed to determine if patient symptoms and computed tomography enterography (CTE) and magnetic resonance enterography (MRE) imaging findings can be used to predict near-term risk of surgery in patients with small bowel Crohn’s disease (CD). Methods CD patients with small bowel strictures undergoing serial CTE or MRE were retrospectively identified. Strictures were defined by luminal narrowing, bowel wall thickening, and unequivocal proximal small bowel dilation. Harvey-Bradshaw index (HBI) was recorded. Stricture observations and measurements were performed on baseline CTE or MRE and compared to with prior and subsequent scans. Patients were divided into those who underwent surgery within 2 years and those who did not. LASSO (least absolute shrinkage and selection operator) regression models were trained and validated using 5-fold cross-validation. Results Eighty-five patients (43.7 ± 15.3 years of age at baseline scan, majority male [57.6%]) had 137 small bowel strictures. Surgery was performed in 26 patients within 2 years from baseline CTE or MRE. In univariate analysis of patients with prior exams, development of stricture on the baseline exam was associated with near-term surgery (P = .006). A mathematical model using baseline features predicting surgery within 2 years included an HBI of 5 to 7 (odds ratio [OR], 1.7 × 105; P = .057), an HBI of 8 to 16 (OR, 3.1 × 105; P = .054), anastomotic stricture (OR, 0.002; P = .091), bowel wall thickness (OR, 4.7; P = .064), penetrating behavior (OR, 3.1 × 103; P = .096), and newly developed stricture (OR: 7.2 × 107; P = .062). This model demonstrated sensitivity of 67% and specificity of 73% (area under the curve, 0.62). Conclusions CTE or MRE imaging findings in combination with HBI can potentially predict which patients will require surgery within 2 years.
An interactive eye‐tracking system for measuring radiologists' visual fixations in volumetric CT images: Implementation and initial eye‐tracking accuracy validation
AbstractPurposeEye‐tracking approaches have been used to understand the visual search process in radiology. However, previous eye‐tracking work in computer tomography (CT) has been limited largely to single cross‐sectional images or video playback of the reconstructed volume, which do not accurately reflect radiologists' visual search activities and their interactivity with three‐dimensional image data at a computer workstation (e.g., scroll, pan, and zoom) for visual evaluation of diagnostic imaging targets. We have developed a platform that integrates eye‐tracking hardware with in‐house‐developed reader workstation software to allow monitoring of the visual search process and reader‐image interactions in clinically relevant reader tasks. The purpose of this work is to validate the spatial accuracy of eye‐tracking data using this platform for different eye‐tracking data acquisition modes.MethodsAn eye‐tracker was integrated with a previously developed workstation designed for reader performance studies. The integrated system captured real‐time eye movement and workstation events at 1000 Hz sampling frequency. The eye‐tracker was operated either in head‐stabilized mode or in free‐movement mode. In head‐stabilized mode, the reader positioned their head on a manufacturer‐provided chinrest. In free‐movement mode, a biofeedback tool emitted an audio cue when the head position was outside the data collection range (general biofeedback) or outside a narrower range of positions near the calibration position (strict biofeedback). Four radiologists and one resident were invited to participate in three studies to determine eye‐tracking spatial accuracy under three constraint conditions: head‐stabilized mode (i.e., with use of a chin rest), free movement with general biofeedback, and free movement with strict biofeedback. Study 1 evaluated the impact of head stabilization versus general or strict biofeedback using a cross‐hair target prior to the integration of the eye‐tracker with the image viewing workstation. In Study 2, after integration of the eye‐tracker and reader workstation, readers were asked to fixate on targets that were randomly distributed within a volumetric digital phantom. In Study 3, readers used the integrated system to scroll through volumetric patient CT angiographic images while fixating on the centerline of designated blood vessels (from the left coronary artery to dorsalis pedis artery). Spatial accuracy was quantified as the offset between the center of the intended target and the detected fixation using units of image pixels and the degree of visual angle.ResultsThe three head position constraint conditions yielded comparable accuracy in the studies using digital phantoms. For Study 1 involving the digital crosshairs, the median ± the standard deviation of offset values among readers were 15.2 ± 7.0 image pixels with the chinrest, 14.2 ± 3.6 image pixels with strict biofeedback, and 19.1 ± 6.5 image pixels with general biofeedback. For Study 2 using the random dot phantom, the median ± standard deviation offset values were 16.7 ± 28.8 pixels with use of a chinrest, 16.5 ± 24.6 pixels using strict biofeedback, and 18.0 ± 22.4 pixels using general biofeedback, which translated to a visual angle of about 0.8° for all three conditions. We found no obvious association between eye‐tracking accuracy and target size or view time. In Study 3 viewing patient images, use of the chinrest and strict biofeedback demonstrated comparable accuracy, while the use of general biofeedback demonstrated a slightly worse accuracy. The median ± standard deviation of offset values were 14.8 ± 11.4 pixels with use of a chinrest, 21.0 ± 16.2 pixels using strict biofeedback, and 29.7 ± 20.9 image pixels using general biofeedback. These corresponded to visual angles ranging from 0.7° to 1.3°.ConclusionsAn integrated eye‐tracker system to assess reader eye movement and interactive viewing in relation to imaging targets demonstrated reasonable spatial accuracy for assessment of visual fixation. The head‐free movement condition with audio biofeedback performed similarly to head‐stabilized mode.
Development of an Objective Model to Define Near-Term Risk of Ileocecal Resection in Patients with Terminal Ileal Crohn Disease
Abstract Background The decision to either escalate medical therapy or proceed to ileocecal resection (ICR) in patients with terminal ileal Crohn disease (CD) remains largely subjective. We sought to develop a risk score for predicting ICR at 1 year from computed tomography or magnetic resonance enterography (CTE/MRE). Methods We conducted a retrospective cohort study including all consecutive adult (> 18 years) patients with imaging findings of terminal ileal CD (Montreal classification: B1, inflammatory predominant; B2, stricturing; or B3, penetrating) on CTE/MRE between January 1, 2016, and December 31, 2016. The risk for ICR at 6 months and at 1 year of CTE/MRE and risk factors associated with ICR, including demographics, CD-specific immunosuppressive therapeutics, and disease presentation at the time of imaging, were determined. Results Of 559 patients, 121 (21.6%) underwent ICR during follow-up (1.4 years [IQR 0.21–1.64 years]); the risk for ICR at 6 months and at 1 year was 18.2% (95% CI 14.7%–21.6%) and 20.5% (95% CI 16.8%–24.1%), respectively. Multivariable analysis revealed Montreal classification (B2, hazard ratio [HR] 2.73, and B3, HR 6.80, both P < 0.0001), upstream bowel dilation (HR 3.06, P < 0.0001), and younger age (19–29 years reference, 30–44 years, HR 0.83 [P = 0.40]; 45–59 years, HR 0.58 [P = 0.04], and 60+ years, HR 0.45 [P = 0.01]) to significantly increase the likelihood of ICR. A predictive nomogram for interval ICR was developed based on these significant variables. Conclusions The presence of CD strictures, penetrating complications, and upstream bowel dilation on CTE/MRE, combined with young age, significantly predict ICR. The suggested risk model may facilitate objective therapeutic decision-making.
Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration
Objectives The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. Materials and Methods A 3D-printed spine with pedicle screws was scanned on a PCD-CT system with and without tin filtration. Image noise and severity of artifacts were measured for low-energy threshold (TL) and TH images. In a prospective, institutional review board–approved, Health Insurance Portability and Accountability Act-compliant study, 20 patients having a clinical energy-integrating detector (EID) CT were scanned on a PCD-CT system using tin filtration. Images were reviewed by 3 radiologists to evaluate visualization of anatomic structures, diagnostic confidence, and image preference. Artifact severity and image noise were measured. Wilcoxon signed rank was used to test differences between PCD-CT TH and EID-CT images. Results Phantom TH images with tin filtration reduced metal artifacts and had comparable noise (32 HU) to TL images (29 HU) acquired without tin filtration. Visualization scores for the cortex, trabeculae, and implant-trabecular interface from PCD-CT TH images (4.4 ± 0.9, 4.4 ± 1.0, and 4.4 ± 1.0) were significantly higher (P < 0.0001) than EID-CT images (3.3 ± 1.3, 3.3 ± 1.2, and 3.3 ± 1.6). A strong preference was shown for PCD-CT TH images due to improved diagnostic confidence and decreased artifact severity. Noise in PCD-CT TH images (93 ± 41 HU) was significantly lower than that in EID-CT images (133 ± 92 HU, P < 0.05). Conclusions Threshold high images acquired with tin filtration on PCD-CT demonstrated a substantial decrease in metal artifacts and an increase in dose efficiency compared with EID-CT.
High-Resolution Chest Computed Tomography Imaging of the Lungs
Objectives The aim of this study was to evaluate if a high-resolution photon-counting detector computed tomography (PCD-CT) system with a 1024×1024 matrix reconstruction can improve the visualization of fine structures in the lungs compared with conventional high-resolution CT (HRCT). Materials and Methods Twenty-two adult patients referred for clinical chest HRCT (mean CTDI vol, 13.58 mGy) underwent additional dose-matched PCD-CT (mean volume CT dose index, 13.37 mGy) after written informed consent. Computed tomography images were reconstructed at a slice thickness of 1.5 mm and an image increment of 1 mm with our routine HRCT reconstruction kernels (B46 and Bv49) at 512 and 1024 matrix sizes for conventional energy-integrating detector (EID) CT scans. For PCD-CT, routine B46 kernel and an additional sharp kernel (Q65, unavailable for EID) images were reconstructed at 1024 matrix size. Two thoracic radiologists compared images from EID and PCD-CT noting the highest level bronchus clearly identified in each lobe of the right lung, and rating bronchial wall conspicuity of third- and fourth-order bronchi. Lung nodules were also compared with the B46/EID/512 images using a 5-point Likert scale. Statistical analysis was performed using a Wilcoxon signed rank test with a P < 0.05 considered significant. Results Compared with B46/EID/512, readers detected higher-order bronchi using B46/PCD/1024 and Q65/PCD/1024 images for every lung lobe (P < 0.0015), but in only the right middle lobe for B46/EID/1024 (P = 0.007). Readers were able to better identify bronchial walls of the third- and fourth-order bronchi better using the Q65/PCD/1024 images (mean Likert scores of 1.1 and 1.5), which was significantly higher compared with B46/EID/1024 or B46/PCD/1024 images (mean difference, 0.8; P < 0.0001). The Q65/PCD/1024 images had a mean nodule score of 1 ± 1.3 for reader 1, and −0.1 (0.9) for reader 2, with one reader having improved nodule evaluation scores for both PCD kernels (P < 0.001), and the other reader not identifying any increased advantage over B46/EID/1024 (P = 1.0). Conclusions High-resolution lung PCD-CT with 1024 image matrix reconstruction increased radiologists' ability to visualize higher-order bronchi and bronchial walls without compromising nodule evaluation compared with current chest CT, creating an opportunity for radiologists to better evaluate airway pathology.