Dilated perivascular spaces (PVSs) are common and easily recognized on imaging. However, rarer giant tumefactive PVSs (GTPVSs) can have unusual multilocular cystic configurations, and are often confused for other pathologic entities, including neoplasms, cystic infarctions, and neuroepithelial cysts. Because GTPVSs are scarcely encountered and even more infrequently operated upon, many radiologists are unaware of the imaging and pathologic features of these lesions. Here, a case of a resected GTPVS is presented, highlighting both its radiologic and histologic characteristics, and discussing how such lesions can be differentiated from their closest mimickers on imaging.
Encephalocele‐associated temporal lobe epilepsy and skull fibrous dysplasia: a report of two cases
Objectives The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. Materials and Methods A 3D-printed spine with pedicle screws was scanned on a PCD-CT system with and without tin filtration. Image noise and severity of artifacts were measured for low-energy threshold (TL) and TH images. In a prospective, institutional review board–approved, Health Insurance Portability and Accountability Act-compliant study, 20 patients having a clinical energy-integrating detector (EID) CT were scanned on a PCD-CT system using tin filtration. Images were reviewed by 3 radiologists to evaluate visualization of anatomic structures, diagnostic confidence, and image preference. Artifact severity and image noise were measured. Wilcoxon signed rank was used to test differences between PCD-CT TH and EID-CT images. Results Phantom TH images with tin filtration reduced metal artifacts and had comparable noise (32 HU) to TL images (29 HU) acquired without tin filtration. Visualization scores for the cortex, trabeculae, and implant-trabecular interface from PCD-CT TH images (4.4 ± 0.9, 4.4 ± 1.0, and 4.4 ± 1.0) were significantly higher (P < 0.0001) than EID-CT images (3.3 ± 1.3, 3.3 ± 1.2, and 3.3 ± 1.6). A strong preference was shown for PCD-CT TH images due to improved diagnostic confidence and decreased artifact severity. Noise in PCD-CT TH images (93 ± 41 HU) was significantly lower than that in EID-CT images (133 ± 92 HU, P < 0.05). Conclusions Threshold high images acquired with tin filtration on PCD-CT demonstrated a substantial decrease in metal artifacts and an increase in dose efficiency compared with EID-CT.
Clinical Assessment of Metal Artifact Reduction Methods in Dual-Energy CT Examinations of Instrumented Spines
Autoimmune epilepsy (AE) is becoming increasingly recognized as a potentially reversible cause of frequent or medically intractable seizures and cognitive deterioration. We describe various presentations of autoimmune encephalopathy which have specifically presented with seizure and describe reported imaging findings. This is organized as a review of the more common autoantibodies which can specifically precipitate seizure according to the intracellular or extracellular location of the targeted antigen. For each antibody, we illustrate their pathophysiology, characteristic clinical presentations with typical effective treatments and prognoses and imaging findings on MRI and PET/CT exams. Parenchymal involvement is variable with the limbic structures typically affected; however, non-limbic cortex, cerebellum, brainstem and basal ganglia can also be involved. In the acute setting, affected regions typically demonstrate T 2 hyperintensity with mild mass effect from edema and increased 18F-fludeoxyglucose uptake. Chronically involved parenchyma will often undergo atrophy and demonstrate decreased metabolism; mesial temporal sclerosis is often the end result when the limbic system is involved. Without treatment, long-term effects from AE range from ongoing cognitive dysfunction and refractory seizures to death. Familiarity with AE may prompt appropriate antibody screening, particularly in cases of refractory seizure disorders. Early investigation and proper management of AE cases may help to prevent parenchymal and neurologic deterioration in these patients.
Utility of Noncontrast Magnetic Resonance Imaging for Detection of Recurrent Vestibular Schwannoma
Background: Gadolinium-enhanced T1-weighted magnetic resonance imaging (MRI) (T1WI) is the conventional imaging technique of choice to detect vestibular schwannoma (VS) recurrence or regrowth, despite suboptimal specificity secondary to enhancing postoperative changes. Furthermore, recent concerns regarding the accumulation of gadolinium in body tissues have led for a call to reduce the number of contrast-enhanced examinations. The objective of the current study is to evaluate the diagnostic accuracy of high-resolution noncontrast (three-dimensional [3D] T2) MRI relative to gadolinium-enhanced T1WI in the detection of VS recurrence after resection. Methods: Following Institutional Review Board approval, 13 consecutive postoperative patients with VS recurrence or regrowth were identified from a prospectively maintained clinical database in which recurrence was determined by progression on serial postoperative MRI examination. Three blinded neuroradiologists retrospectively evaluated a total of 41 postoperative MRI examinations from these patients using only gadolinium-enhanced T1WI and 3D T2 MRI for recurrence or regrowth. Interobserver agreement, differences in detection between the two sequences, and the sensitivity and specificity of 3D T2 MRI were assessed. Results: Fifteen of the 41 postoperative MRIs demonstrated progression, as determined by examiner consensus on the gadolinium-enhanced T1WI. Agreement, measured using Krippendorff's alpha, was 0.82 for the 3D T2 images and 0.83 for the contrast-enhanced T1WI. All the three examiners demonstrated no difference in the detection of progression between the two sequences (McNemar's test p values 0.69 for examiner 1, 0.63 for examiner 2, and 0.99 for examiner 3). The sensitivity of 3D T2 was 0.78 (CI 0.60–0.96), while the specificity was 0.94 (CI 0.86–1.00). Conclusion: Noncontrast high-resolution 3D T2 MRI seems sufficient to assess for recurrence or regrowth after VS resection. The results of this study have implications for reducing cost, time, and adverse events associated with gadolinium administration in this population requiring serial follow-up examinations. These promising, yet preliminary findings warrant confirmation with a larger prospective cohort of patients.
CT Dental Artifact: Comparison of an Iterative Metal Artifact Reduction Technique with Weighted Filtered Back-Projection
Background Dental hardware produces streak artifacts on computed tomography (CT) images reconstructed with the standard weighted filtered back projection (wFBP) method. Purpose To perform a preliminary evaluation of an iterative metal artifact reduction (IMAR) technique to assess its ability to improve anatomic visualization over wFBP in patients with dental amalgam or other hardware. Material and Methods CT images from patients with dental hardware were reconstructed using wFBP and IMAR software and soft-tissue or bone window/level settings. The anatomy most affected by metal artifacts was identified. Two neuroradiologists determined subjective and objective imaging features, including overall metal artifact score (1 = severe artifacts, 5 = no artifacts), soft-tissue visualization score of the most-compromised structure, and artifact length along the skin surface. CT numbers were used to quantify artifact severity. Results Twenty-four patients were included. IMAR improved overall metal artifact score in 18/24 cases (median =2 ± 0.9 vs. 1 ± 0.6, P < 0.001). Mean CT number in the most-affected anatomical structure significantly improved with IMAR (94.6 vs. 219 HU, P = 0.002) and length of affected skin surface decreased (40.4 mm vs. 118.7 mm, P < 0.001). However, osseous/dental artifactual defects were found in 22/24 cases with IMAR vs. 11/24 with wFBP. Conclusion IMAR software reduced metal artifact both subjectively and objectively and improved visualization of adjacent soft tissues. However, it produced a higher rate of artifactual defects in the teeth and bones than wFBP. Our findings support the use of IMAR as a valuable complement to, but not a replacement for, standard wFBP image reconstruction.
Imaging Appearance of Advanced Chronic Adhesive Arachnoiditis: A Retrospective Review