Systematic optimization of ultrasound grayscale imaging presets and its application in abdominal scanning
Long, Zaiyang , Tradup, Donald J., Stekel, Scott F. , Callstrom, Matthew R. , Hangiandreou, Nicholas J., Zhou, Wei , Zhou, Wei

Journal of Applied Clinical Medical Physics | August 12, 2020 | Volume: 21 | Issue: 10 | Pages: 192-199

10.1002/acm2.13000 Get It

AbstractPurposeUltrasound grayscale imaging preset optimization has often been qualitative and dependent upon vendor application specialists. This study aimed to propose a systematic approach for grayscale imaging preset optimization and apply the approach in a clinical abdominal scan setting.MethodsA six‐step approach was detailed including identification of clinical task, adjustment of basic parameters, fine‐tuning of advanced parameters, image performance metrics confirmation, clinical evaluation and data analysis, and implementation of new presets and monitoring of clinical usage. Its application in an abdominal scanning task was described for each step with phantoms, volunteers, and software tools.ResultsClinical image data analytics facilitated the understanding of the imaging task, relevant transducers, and target characteristics, in addition to specific requests from radiologists. Quantitative measurements were made on global image contrast and gray map function. In addition, clinically relevant phantoms and volunteer scans without and with acoustic distortion layers were involved to determine the new presets. Furthermore, phantom signal to noise ratio study and clinical evaluation using volunteers with different body habitus were utilized to confirm the superiority of the new presets. Quantitative clinical usage monitoring demonstrated successful implementation of the new presets.ConclusionsA systematic approach for grayscale imaging preset optimization has been proposed and successfully applied for a specific clinical task. This approach was designed to be generalizable and relatively flexible, which would facilitate movement away from previous qualitative and subjective approaches.
Determination of iodine detectability in different types of multiple-energy images for a photon-counting detector computed tomography system
Michalak, Gregory J. , Weaver, Jayse , Ferrero, Andrea , Gong, Hao , Fetterly, Kenneth A. , Zhou, Wei , McCollough, Cynthia H , Leng, Shuai , Zhou, Wei , McCollough, Cynthia H. , Leng, Shuai

Journal of Medical Imaging | October 15, 2019 | Volume: 6 | Issue: 04 | Pages: 1

10.1117/1.jmi.6.4.043501 Get It

Evaluation of Shimming Techniques on MRI Breast Image Quality at 1.5T
Favazza, Christopher , Axmacher, Jessica A, Trzasko, Joshua D. , Lee, Christine U. , Zhou, Wei , Favazza, Christopher P, Zhou, Wei , Geske, Jennifer R.

Journal of Breast Imaging | August 23, 2019 | Volume: 1 | Issue: 3 | Pages: 199-204

10.1093/jbi/wbz045 Get It

Abstract Objective The quality of all clinical MRI is dependent on B0 homogeneity, which is optimized during the shimming part of a prescan or preparatory phase before image acquisition. The purpose of this study was to assess shimming techniques clinically employed for breast MRI across our practice, and to determine factors that correlate with higher image quality for contrast-enhanced breast MRI at 1.5T. Methods One hundred consecutive female patients were retrospectively collected with Institutional Review Board approval. Shimming-related parameters, including shim-box placement and shimming gradient offsets were extracted from prior contrast-enhanced 3D fat-suppressed T1-weighted gradient echo image acquisitions. Three breast radiologists evaluated these images for fat saturation, breast density, overall image quality, and artifacts. Technologist experience was also evaluated for variability of shimming. Generalized linear mixed models were used to compare acquisition parameters between fat saturation. P < 0.05 was considered as statistical significance. Results The percentage of soft tissue inside the field of view (FOV) (ie, Tissue/FOV) in the good fat-saturation group (0.37 ± 0.06) was significantly lower (P < 0.01) than that in the poor fat-saturation group (0.39 ± 0.06). Other shimming-related parameters were found not significantly affecting the fat-saturation outcomes. Technologists with more experience tended to have less variable shimming performance than junior technologists did. Conclusions The quality of clinical MRI and especially breast MRI is highly dependent on shimming. Decreasing Tissue/FOV was associated with good image quality (good fat saturation). Optimization of shimming may require manual shimming or higher-order field-correction strategies.
Ultrasound grayscale image quality comparison between a 2D intracavitary transducer and a 3D intracavitary transducer used in 2D mode: A phantom study
Zhou, Wei , Long, Zaiyang , Tradup, Donald J., Stekel, Scott F. , Browne, Jacinta E. , Brown, Douglas L. , Hangiandreou, Nicholas J., Zhou, Wei , Browne, Jacinta

Journal of Applied Clinical Medical Physics | April 19, 2019 | Volume: 20 | Issue: 6 | Pages: 134-140

10.1002/acm2.12590 Get It

AbstractPurposeIt is unclear if a 3D transducer with the special design of mechanical swing or 2D array could provide acceptable 2D grayscale image quality for the general diagnosis purpose. The aim of this study is to compare the 2D image quality of a 3D intracavitary transducer with a conventional 2D intracavitary transducer using clinically relevant phantom experiments.MethodsAll measurements were performed on a GE Logiq E9 scanner with both a 2D (IC5‐9‐D) and a 3D (RIC5‐9‐D) transducer used in 2D mode. Selection of phantom targets and acquisition parameters were determined from analysis of 33 clinical pelvic exams. Depth of penetration (DOP), contrast response, contrast of anechoic cylinders (diameter: 6.7 mm) at 1.5 and 4.5 cm depths in transverse planes, and in‐plane resolution represented by full‐width half‐maximum of pin targets at multiple depths were measured with transmit frequencies of 7 and 8 MHz. Spherical signal‐noise‐ratio (SNR) (diameter: 4 and 2 mm) at multiple depths were measured at 8 MHz.ResultsRIC5‐9‐D demonstrated <8% decrease in DOP for both transmit frequencies (7 MHz: 69.7 ± 8.2 mm; 8 MHz: 64.3 ± 7.8 mm) compared with those from IC5‐9‐D (7 MHz: 73.9 ± 4.4 mm; 8 MHz: 69.4 ± 7.8 mm). A decreased anechoic contrast was observed with a 4.5 cm depth for RIC5‐9‐D (7 MHz: 23.2 ± 1.8 dB, P > 0.05; 8 MHz: 17.7 ± 0.9 dB, P < 0.01) compared with IC5‐9‐D (7 MHz: 25.9 ± 1.2 dB; 8 MHz: 21.5 ± 0.8 dB). The contrast response and spatial resolution performance were comparable between the two transducers. RIC5‐9‐D showed comparable SNR of anechoic spheres compared to IC5‐9‐D.Conclusions2D images from a 3D probe exhibited comparable overall image quality for routine clinical pelvic imaging.
A deep learning‐ and partial least square regression‐based model observer for a low‐contrast lesion detection task in CT
Gong, Hao , Yu, Lifeng , Dilger, Samantha K. N. , Ren, Liqiang , Zhou, Wei , Dilger, Samantha K, Zhou, Wei , Yu, Lifeng , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H.

Medical Physics | March 20, 2019 | Volume: 46 | Issue: 5 | Pages: 2052-2063

10.1002/mp.13500 Get It

PurposeThis work aims to develop a new framework of image quality assessment using deep learning‐based model observer (DL‐MO) and to validate it in a low‐contrast lesion detection task that involves CT images with patient anatomical background.MethodsThe DL‐MO was developed using the transfer learning strategy to incorporate a pretrained deep convolutional neural network (CNN), a partial least square regression discriminant analysis (PLS‐DA) model and an internal noise component. The CNN was previously trained to achieve the state‐of‐the‐art classification accuracy over a natural image database. The earlier layers of the CNN were used as a deep feature extractor, with the assumption that similarity exists between the CNN and the human visual system. The PLSR model was used to further engineer the deep feature for the lesion detection task in CT images. The internal noise component was incorporated to model the inefficiency and variability of human observer (HO) performance, and to generate the ultimate DL‐MO test statistics. Seven abdominal CT exams were retrospectively collected from the same type of CT scanners. To compare DL‐MO with HO, 12 experimental conditions with varying lesion size, lesion contrast, radiation dose, and reconstruction types were generated, each condition with 154 trials. CT images of a real liver metastatic lesion were numerically modified to generate lesion models with four lesion sizes (5, 7, 9, and 11 mm) and three contrast levels (15, 20, and 25 HU). The lesions were inserted into patient liver images using a projection‐based method. A validated noise insertion tool was used to synthesize CT exams with 50% and 25% of routine radiation dose level. CT images were reconstructed using the weighted filtered back projection algorithm and an iterative reconstruction algorithm. Four medical physicists performed a two‐alternative forced choice (2AFC) detection task (with multislice scrolling viewing mode) on patient images across the 12 experimental conditions. DL‐MO was operated on the same datasets. Statistical analyses were performed to evaluate the correlation and agreement between DL‐MO and HO.ResultsA statistically significant positive correlation was observed between DL‐MO and HO for the 2AFC low‐contrast detection task that involves patient liver background. The corresponding Pearson product moment correlation coefficient was 0.986 [95% confidence interval (0.950, 0.996)]. Bland–Altman agreement analysis did not indicate statistically significant differences.ConclusionsThe proposed DL‐MO is highly correlated with HO in a low‐contrast detection task that involves realistic patient liver background. This study demonstrated the potential of the proposed DL‐MO to assess image quality directly based on patient images in realistic, clinically relevant CT tasks.
Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration
Zhou, Wei , Bartlett, David J. , Glazebrook, Katrina N. , Carter, Rickey E. , Zhou, Wei , Carter, Rickey E , Diehn, Felix E. , Kotsenas, Amy L. , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Investigative Radiology | December 18, 2018 | Volume: 54 | Issue: 4 | Pages: 204-211

10.1097/rli.0000000000000535 Get It

Objectives The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. Materials and Methods A 3D-printed spine with pedicle screws was scanned on a PCD-CT system with and without tin filtration. Image noise and severity of artifacts were measured for low-energy threshold (TL) and TH images. In a prospective, institutional review board–approved, Health Insurance Portability and Accountability Act-compliant study, 20 patients having a clinical energy-integrating detector (EID) CT were scanned on a PCD-CT system using tin filtration. Images were reviewed by 3 radiologists to evaluate visualization of anatomic structures, diagnostic confidence, and image preference. Artifact severity and image noise were measured. Wilcoxon signed rank was used to test differences between PCD-CT TH and EID-CT images. Results Phantom TH images with tin filtration reduced metal artifacts and had comparable noise (32 HU) to TL images (29 HU) acquired without tin filtration. Visualization scores for the cortex, trabeculae, and implant-trabecular interface from PCD-CT TH images (4.4 ± 0.9, 4.4 ± 1.0, and 4.4 ± 1.0) were significantly higher (P < 0.0001) than EID-CT images (3.3 ± 1.3, 3.3 ± 1.2, and 3.3 ± 1.6). A strong preference was shown for PCD-CT TH images due to improved diagnostic confidence and decreased artifact severity. Noise in PCD-CT TH images (93 ± 41 HU) was significantly lower than that in EID-CT images (133 ± 92 HU, P < 0.05). Conclusions Threshold high images acquired with tin filtration on PCD-CT demonstrated a substantial decrease in metal artifacts and an increase in dose efficiency compared with EID-CT.
150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology
Rajendran, Kishore , Gong, Hao , Zhou, Wei , Halaweish, Ahmed F., Henning, André , Kappler, S. , Baer, Matthias , Rajendran, Kishore , Zhou, Wei , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H.

Investigative Radiology | May 31, 2018 | Volume: 53 | Issue: 11 | Pages: 655-662

10.1097/rli.0000000000000488 Get It

Objective The aims of this study were to quantitatively assess two new scan modes on a photon-counting detector computed tomography system, each designed to maximize spatial resolution, and to qualitatively demonstrate potential clinical impact using patient data. Materials and Methods This Health Insurance Portability Act–compliant study was approved by our institutional review board. Two high–spatial-resolution scan modes (Sharp and UHR) were evaluated using phantoms to quantify spatial resolution and image noise, and results were compared with the standard mode (Macro). Patients were scanned using a conventional energy-integrating detector scanner and the photon-counting detector scanner using the same radiation dose. In first patient images, anatomic details were qualitatively evaluated to demonstrate potential clinical impact. Results Sharp and UHR modes had a 69% and 87% improvement in in-plane spatial resolution, respectively, compared with Macro mode (10% modulation-translation-function values of 16.05, 17.69, and 9.48 lp/cm, respectively). The cutoff spatial frequency of the UHR mode (32.4 lp/cm) corresponded to a limiting spatial resolution of 150 μm. The full-width-at-half-maximum values of the section sensitivity profiles were 0.41, 0.44, and 0.67 mm for the thinnest image thickness for each mode (0.25, 0.25, and 0.5 mm, respectively). At the same in-plane spatial resolution, Sharp and UHR images had up to 15% lower noise than Macro images. Patient images acquired in Sharp mode demonstrated better delineation of fine anatomic structures compared with Macro mode images. Conclusions Phantom studies demonstrated superior resolution and noise properties for the Sharp and UHR modes relative to the standard Macro mode and patient images demonstrated the potential benefit of these scan modes for clinical practice.
Targeted Imaging of Renal Fibrosis Using Antibody-Conjugated Gold Nanoparticles in Renal Artery Stenosis
Zhu, Xiang-Yang, Zou, Xiangyu , Yu, Zhicong , Ferguson, Christopher M. , Zhou, Wei , Lerman, Lilach O. , Zhou, Wei , Mukherjee, Rahul K , McCollough, Cynthia H.

Investigative Radiology | May 4, 2018 | Volume: 53 | Issue: 10 | Pages: 623-628

10.1097/rli.0000000000000476 Get It

Objectives The ability to determine the severity of renal fibrosis, which is involved in most chronic kidney diseases, may be beneficial for monitoring disease progression and management. The aim of this study was to assess a new method involving gold nanoparticles conjugated to an anti-collagen-I antibody (Co-I-AuNPs) as a computed tomography (CT) imaging contrast for the evaluation of renal fibrosis in situ. Materials and Methods Gold nanoparticles conjugated to an anti-collagen-I antibody were prepared using gold chloride reduction with sodium citrate and coated with polyethylene glycol (PEG), and their size was determined by electron microscopy and nanoparticle tracking analysis. Anti-collagen-I antibody was then conjugated to PEG-SH/COOH on the AuNP surface. The success of antibody conjugation was tested in vitro using collagen-coated plate and mouse stenotic kidney sections and in vivo using micro-CT and multidetector CT imaging. Results Bare AuNPs were 18.7 ± 0.6 nm and PEG-coated AuNPs were 45.3 ± 0.1 nm in size. In vitro, Co-I-AuNPs specifically bound to both a collagen-coated plate and mouse fibrotic kidneys. Furthermore, the stenotic mouse kidney showed increased Co-I-AuNPs retention compared with the contralateral kidney (59.3 ± 5.1 vs 45.1 ± 1.7 HU, P = 0.05), which correlated with its collagen deposition. Micro-CT also detected gold signals in situ in the Co-I-AuNP-injected kidney, which colocalized with histological trichrome staining. Conclusion Gold nanoparticles conjugated to an anti-collagen-I antibody are able to visualize kidney fibrosis in vitro and in situ and may be useful for nondestructive quantification of tissue fibrosis.
Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon-counting detector computed tomography system
Zhou, Wei , Montoya, Juan , McCollough, Cynthia, McCollough, Cynthia H , Leng, Shuai , Zhou, Wei , Montoya, Juan, Gutjahr, Ralf, Ferrero, Andrea, Halaweish, Ahmed F , Kappler, Steffen

Journal of Medical Imaging | November 16, 2017 | Volume: 4 | Issue: 04 | Pages: 1

10.1117/1.jmi.4.4.043502 Get It

Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets
Zhou, Wei , Yu, Zhicong , Halaweish, Ahmed, Krauß, Bernhard , Schmidt, Bernhard , Yu, Lifeng , Kappler, S. , McCollough, C, McCollough, Cynthia, Leng, Shuai , Halaweish, Ahmed, Yu, Lifeng , Zhou, Wei

Physics in Medicine & Biology | July 20, 2017 | Volume: 62 | Issue: 17 | Pages: 7216-7232

10.1088/1361-6560/aa8103 Get It

Abstract Photon-counting computed tomography (PCCT) uses a photon counting detector to count individual photons and allocate them to specific energy bins by comparing photon energy to preset thresholds. This enables simultaneous multi-energy CT with a single source and detector. Phantom studies were performed to assess the spectral performance of a research PCCT scanner by assessing the accuracy of derived images sets. Specifically, we assessed the accuracy of iodine quantification in iodine map images and of CT number accuracy in virtual monoenergetic images (VMI). Vials containing iodine with five known concentrations were scanned on the PCCT scanner after being placed in phantoms representing the attenuation of different size patients. For comparison, the same vials and phantoms were also scanned on 2nd and 3rd generation dual-source, dual-energy scanners. After material decomposition, iodine maps were generated, from which iodine concentration was measured for each vial and phantom size and compared with the known concentration. Additionally, VMIs were generated and CT number accuracy was compared to the reference standard, which was calculated based on known iodine concentration and attenuation coefficients at each keV obtained from the U.S. National Institute of Standards and Technology (NIST). Results showed accurate iodine quantification (root mean square error of 0.5 mgI/cc) and accurate CT number of VMIs (percentage error of 8.9%) using the PCCT scanner. The overall performance of the PCCT scanner, in terms of iodine quantification and VMI CT number accuracy, was comparable to that of EID-based dual-source, dual-energy scanners.