Back to Authors

Krauß, Bernhard

https://orcid.org/0000-0001-8584-2941

Mayo Clinic

Siemens Healthineers (Germany)

Citations 4

A comparison of relative proton stopping power measurements across patient size using dual- and single-energy CT
Michalak, Gregory J. , Taasti, Vicki Trier , Krauß, Bernhard , Deisher, A., Halaweish, Ahmed F., Deisher, Amanda, McCollough, Cynthia, McCollough, Cynthia H.

Acta Oncologica | September 8, 2017 | Volume: 56 | Issue: 11 | Pages: 1465-1471

10.1080/0284186x.2017.1372625 Get It

Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets
Zhou, Wei , Yu, Zhicong , Halaweish, Ahmed, Krauß, Bernhard , Schmidt, Bernhard , Yu, Lifeng , Kappler, S. , McCollough, C, McCollough, Cynthia, Leng, Shuai , Halaweish, Ahmed, Yu, Lifeng , Zhou, Wei

Physics in Medicine & Biology | July 20, 2017 | Volume: 62 | Issue: 17 | Pages: 7216-7232

10.1088/1361-6560/aa8103 Get It

Abstract Photon-counting computed tomography (PCCT) uses a photon counting detector to count individual photons and allocate them to specific energy bins by comparing photon energy to preset thresholds. This enables simultaneous multi-energy CT with a single source and detector. Phantom studies were performed to assess the spectral performance of a research PCCT scanner by assessing the accuracy of derived images sets. Specifically, we assessed the accuracy of iodine quantification in iodine map images and of CT number accuracy in virtual monoenergetic images (VMI). Vials containing iodine with five known concentrations were scanned on the PCCT scanner after being placed in phantoms representing the attenuation of different size patients. For comparison, the same vials and phantoms were also scanned on 2nd and 3rd generation dual-source, dual-energy scanners. After material decomposition, iodine maps were generated, from which iodine concentration was measured for each vial and phantom size and compared with the known concentration. Additionally, VMIs were generated and CT number accuracy was compared to the reference standard, which was calculated based on known iodine concentration and attenuation coefficients at each keV obtained from the U.S. National Institute of Standards and Technology (NIST). Results showed accurate iodine quantification (root mean square error of 0.5 mgI/cc) and accurate CT number of VMIs (percentage error of 8.9%) using the PCCT scanner. The overall performance of the PCCT scanner, in terms of iodine quantification and VMI CT number accuracy, was comparable to that of EID-based dual-source, dual-energy scanners.
Dual energy CT kidney stone differentiation in photon counting computed tomography
Gutjahr, Ralf , Polster, Christoph, Henning, André , Kappler, S. , Sedlmair, Martin , Schmidt, Bernhard , Krauß, Bernhard , Flohr, Thomas , Leng, Shuai , McCollough, Cynthia H.

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 1013237

10.1117/12.2252021 Get It

Feasibility of Discriminating Uric Acid From Non–Uric Acid Renal Stones Using Consecutive Spatially Registered Low- and High-Energy Scans Obtained on a Conventional CT Scanner
Shiung, Maria, Qu, Mingliang , Vrtiska, Terri J., Grant, Katharine L., Krauß, Bernhard , Schmidt, Bernhard , Leng, Shuai , Ai, Songtao , Lieske, John C. , McCollough, Cynthia H.

American Journal of Roentgenology | December 24, 2014 | Volume: 204 | Issue: 1 | Pages: 92-97

10.2214/ajr.13.11911 Get It