Back to Authors

Yu, Zhicong

0009-0007-5975-3110

Mayo Clinic

Mayo Clinic

Citations 11

Low‐dose CT image and projection dataset
Moen, Taylor R., Chen, Baiyu , Holmes, David R. , Yu, Zhicong , Yu, Lifeng , Duan, Xinhui , Yu, Lifeng , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H.

Medical Physics | November 17, 2020 | Volume: 48 | Issue: 2 | Pages: 902-911

10.1002/mp.14594 Get It

Purpose To describe a large, publicly available dataset comprising computed tomography (CT) projection data from patient exams, both at routine clinical doses and simulated lower doses. Acquisition and Validation Methods The library was developed under local ethics committee approval. Projection and image data from 299 clinically performed patient CT exams were archived for three types of clinical exams: noncontrast head CT scans acquired for acute cognitive or motor deficit, low‐dose noncontrast chest scans acquired to screen high‐risk patients for pulmonary nodules, and contrast‐enhanced CT scans of the abdomen acquired to look for metastatic liver lesions. Scans were performed on CT systems from two different CT manufacturers using routine clinical protocols. Projection data were validated by reconstructing the data using several different reconstruction algorithms and through use of the data in the 2016 Low Dose CT Grand Challenge. Reduced dose projection data were simulated for each scan using a validated noise‐insertion method. Radiologists marked location and diagnosis for detected pathologies. Reference truth was obtained from the patient medical record, either from histology or subsequent imaging. Data Format and Usage Notes Projection datasets were converted into the previously developed DICOM‐CT‐PD format, which is an extended DICOM format created to store CT projections and acquisition geometry in a nonproprietary format. Image data are stored in the standard DICOM image format and clinical data in a spreadsheet. Materials are provided to help investigators use the DICOM‐CT‐PD files, including a dictionary file, data reader, and user manual. The library is publicly available from The Cancer Imaging Archive ( https://doi.org/10.7937/9npb‐2637 ). Potential Applications This CT data library will facilitate the development and validation of new CT reconstruction and/or denoising algorithms, including those associated with machine learning or artificial intelligence. The provided clinical information allows evaluation of task‐based diagnostic performance.
Overcoming calcium blooming and improving the quantification accuracy of percent area luminal stenosis by material decomposition of multi-energy computed tomography datasets
Li, Zhoubo , Halaweish, Ahmed F., Yu, Zhicong , Yu, Lifeng , Ritman, Erik L., Leng, Shuai , Halaweish, Ahmed F , Yu, Lifeng , McCollough, Cynthia H , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | October 1, 2020 | Volume: 7 | Issue: 05 | Pages: No page available

10.1117/1.jmi.7.5.053501 Get It

Targeted Imaging of Renal Fibrosis Using Antibody-Conjugated Gold Nanoparticles in Renal Artery Stenosis
Zhu, Xiang-Yang, Zou, Xiangyu , Yu, Zhicong , Ferguson, Christopher M. , Zhou, Wei , Lerman, Lilach O. , Zhou, Wei , Mukherjee, Rahul K , McCollough, Cynthia H.

Investigative Radiology | May 4, 2018 | Volume: 53 | Issue: 10 | Pages: 623-628

10.1097/rli.0000000000000476 Get It

Objectives The ability to determine the severity of renal fibrosis, which is involved in most chronic kidney diseases, may be beneficial for monitoring disease progression and management. The aim of this study was to assess a new method involving gold nanoparticles conjugated to an anti-collagen-I antibody (Co-I-AuNPs) as a computed tomography (CT) imaging contrast for the evaluation of renal fibrosis in situ. Materials and Methods Gold nanoparticles conjugated to an anti-collagen-I antibody were prepared using gold chloride reduction with sodium citrate and coated with polyethylene glycol (PEG), and their size was determined by electron microscopy and nanoparticle tracking analysis. Anti-collagen-I antibody was then conjugated to PEG-SH/COOH on the AuNP surface. The success of antibody conjugation was tested in vitro using collagen-coated plate and mouse stenotic kidney sections and in vivo using micro-CT and multidetector CT imaging. Results Bare AuNPs were 18.7 ± 0.6 nm and PEG-coated AuNPs were 45.3 ± 0.1 nm in size. In vitro, Co-I-AuNPs specifically bound to both a collagen-coated plate and mouse fibrotic kidneys. Furthermore, the stenotic mouse kidney showed increased Co-I-AuNPs retention compared with the contralateral kidney (59.3 ± 5.1 vs 45.1 ± 1.7 HU, P = 0.05), which correlated with its collagen deposition. Micro-CT also detected gold signals in situ in the Co-I-AuNP-injected kidney, which colocalized with histological trichrome staining. Conclusion Gold nanoparticles conjugated to an anti-collagen-I antibody are able to visualize kidney fibrosis in vitro and in situ and may be useful for nondestructive quantification of tissue fibrosis.
Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets
Zhou, Wei , Yu, Zhicong , Halaweish, Ahmed, Krauß, Bernhard , Schmidt, Bernhard , Yu, Lifeng , Kappler, S. , McCollough, C, McCollough, Cynthia, Leng, Shuai , Halaweish, Ahmed, Yu, Lifeng , Zhou, Wei

Physics in Medicine & Biology | July 20, 2017 | Volume: 62 | Issue: 17 | Pages: 7216-7232

10.1088/1361-6560/aa8103 Get It

Abstract Photon-counting computed tomography (PCCT) uses a photon counting detector to count individual photons and allocate them to specific energy bins by comparing photon energy to preset thresholds. This enables simultaneous multi-energy CT with a single source and detector. Phantom studies were performed to assess the spectral performance of a research PCCT scanner by assessing the accuracy of derived images sets. Specifically, we assessed the accuracy of iodine quantification in iodine map images and of CT number accuracy in virtual monoenergetic images (VMI). Vials containing iodine with five known concentrations were scanned on the PCCT scanner after being placed in phantoms representing the attenuation of different size patients. For comparison, the same vials and phantoms were also scanned on 2nd and 3rd generation dual-source, dual-energy scanners. After material decomposition, iodine maps were generated, from which iodine concentration was measured for each vial and phantom size and compared with the known concentration. Additionally, VMIs were generated and CT number accuracy was compared to the reference standard, which was calculated based on known iodine concentration and attenuation coefficients at each keV obtained from the U.S. National Institute of Standards and Technology (NIST). Results showed accurate iodine quantification (root mean square error of 0.5 mgI/cc) and accurate CT number of VMIs (percentage error of 8.9%) using the PCCT scanner. The overall performance of the PCCT scanner, in terms of iodine quantification and VMI CT number accuracy, was comparable to that of EID-based dual-source, dual-energy scanners.
Estimation of signal and noise for a whole-body research photon-counting CT system
Li, Zhoubo , Yu, Zhicong , Kappler, S. , Leng, Shuai , McCollough, Cynthia H. , McCollough, Cynthia H , Leng, Shuai , Kappler, Steffen

Journal of Medical Imaging | June 22, 2017 | Volume: 4 | Issue: 2 | Pages: 023505

10.1117/1.jmi.4.2.023505 Get It

Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system
Yu, Zhicong , Halaweish, Ahmed F., Kappler, S. , Hähn, Katharina, Henning, André , Li, Zhoubo , Lane, John I. , Levin, David L. , Jorgensen, Steven M., Ritman, Erik L., Lane, John , Jorgensen, Steven, Ritman, Erik, McCollough, Cynthia, Leng, Shuai , McCollough, Cynthia H. , Leng, Shuai , Kappler, Steffen

Journal of Medical Imaging | December 22, 2016 | Volume: 3 | Issue: 4 | Pages: 043504

10.1117/1.jmi.3.4.043504 Get It

Noise performance of low-dose CT: comparison between an energy integrating detector and a photon counting detector using a whole-body research photon counting CT scanner
Yu, Zhicong , Kappler, S. , Hähn, Katharina, Li, Zhoubo , Halaweish, Ahmed F., Henning, André , Leng, Shuai , McCollough, Cynthia H. , McCollough, Cynthia H , Leng, Shuai , Kappler, Steffen

Journal of Medical Imaging | December 14, 2016 | Volume: 3 | Issue: 4 | Pages: 043503

10.1117/1.jmi.3.4.043503 Get It

Spectral prior image constrained compressed sensing (spectral PICCS) for photon-counting computed tomography
Yu, Zhicong , Li, Zhoubo , Leng, Shuai , McCollough, Cynthia H.

Physics in Medicine & Biology | August 23, 2016 | Volume: 61 | Issue: 18 | Pages: 6707-6732

10.1088/0031-9155/61/18/6707 Get It

Abstract Photon-counting computed tomography (PCCT) is an emerging imaging technique that enables multi-energy imaging with only a single scan acquisition. To enable multi-energy imaging, the detected photons corresponding to the full x-ray spectrum are divided into several subgroups of bin data that correspond to narrower energy windows. Consequently, noise in each energy bin increases compared to the full-spectrum data. This work proposes an iterative reconstruction algorithm for noise suppression in the narrower energy bins used in PCCT imaging. The algorithm is based on the framework of prior image constrained compressed sensing (PICCS) and is called spectral PICCS; it uses the full-spectrum image reconstructed using conventional filtered back-projection as the prior image. The spectral PICCS algorithm is implemented using a constrained optimization scheme with adaptive iterative step sizes such that only two tuning parameters are required in most cases. The algorithm was first evaluated using computer simulations, and then validated by both physical phantoms and in vivo swine studies using a research PCCT system. Results from both computer-simulation and experimental studies showed substantial image noise reduction in narrow energy bins (43–73%) without sacrificing CT number accuracy or spatial resolution.
Extended ellipse-line-ellipse trajectory for long-object cone-beam imaging with a mounted C-arm system
Yu, Zhicong , Lauritsch, Günter, Dennerlein, Frank, Mao, Yanfei , Hornegger, Joachim, Noo, Frédéric , Mao, Yanfei

Physics in Medicine & Biology | February 8, 2016 | Volume: 61 | Issue: 4 | Pages: 1829-1851

10.1088/0031-9155/61/4/1829 Get It

Abstract Recent reports show that three-dimensional cone-beam (CB) imaging with a floor-mounted (or ceiling-mounted) C-arm system has become a valuable tool in interventional radiology. Currently, a circular short scan is used for data acquisition, which inevitably yields CB artifacts and a short coverage in the direction of the patient table. To overcome these two limitations, a more sophisticated data acquisition geometry is needed. This geometry should be complete in terms of Tuy’s condition and should allow continuous scanning, while being compatible with the mechanical constraints of mounted C-arm systems. Additionally, the geometry should allow accurate image reconstruction from truncated data. One way to ensure such a feature is to adopt a trajectory that provides full R-line coverage within the field-of-view (FOV). An R-line is any segment of line that connects two points on a source trajectory, and the R-line coverage is the set of points that belong to an R-line. In this work, we propose a novel geometry called the extended ellipse-line-ellipse (ELE) for long-object imaging with a mounted C-arm system. This trajectory is built from modules consisting of two elliptical arcs connected by a line. We demonstrate that the extended ELE can be configured in many ways so that full R-line coverage is guaranteed. Both tight and relaxed parametric settings are presented. All results are supported by extensive mathematical proofs provided in appendices. Our findings make the extended ELE trajectory attractive for axially-extended FOV imaging in interventional radiology.
Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array
Yu, Zhicong , Jorgensen, Steven M., Li, Zhoubo , Gutjahr, Ralf , Chen, Baiyu , Halaweish, Ahmed F., Kappler, S. , Yu, Lifeng , Ritman, Erik L., Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H.

Physics in Medicine & Biology | February 2, 2016 | Volume: 61 | Issue: 4 | Pages: 1572-1595

10.1088/0031-9155/61/4/1572 Get It

Abstract This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x-ray photon flux.