Individualized Delay for Abdominal Computed Tomography Angiography Bolus-Tracking Based on Sequential Monitoring: Increased Aortic Contrast Permits Decreased Injection Rate and Lower Iodine Dose
Gutjahr, Ralf , Lee, Yong S. , Halaweish, Ahmed F., Suresh, Vighnesh , Weber, Nikkole M. , Vrtiska, Terri J., Williamson, Eric E. , Schmidt, Bernhard , Fletcher, Joel G. , McCollough, Cynthia H.

Journal of Computer Assisted Tomography | July 3, 2019 | Volume: 43 | Issue: 4 | Pages: 612-618

10.1097/rct.0000000000000874 Get It

Objective The aim of this study was to determine if computed tomography (CT) angiography using an individualized transition delay (CTA-ID) would facilitate reductions in injection rate and iodine dose. Methods The CTA-ID was performed in 20 patients with routine injection rate and iodine dose; 20 patients with injection rate lowered by 1 mL/s; and 40 patients with injection rate lowered by 1 mL/s with 29% less iodine. Routine CTAs in the same or size-matched patients served as controls. Diagnostic image quality and intra-arterial CT numbers were assessed. Results The median transition delay between aortic threshold and CTA-ID image acquisition was significantly longer than with conventional bolus tracking (mean increase, 13.3 seconds; P < 0.0001), with image quality being the same or better. Intra-arterial CT numbers were 200 Hounsfield units or greater for 80 of 80 CTA-ID, but not for 6 of 49 (12%) internal control or for 11 of 80 (14%) size-matched control patients. Conclusion The CTA-ID bolus-tracking software alters transition delays to permit diagnostic CTA examinations despite slower injection rate and less iodine.
Detection and Characterization of Renal Stones by Using Photon-Counting–based CT
Marcus, Roy , Fletcher, Joel G. , Ferrero, Andrea , Leng, Shuai , Halaweish, Ahmed F., Gutjahr, Ralf , Vrtiska, Terri J., Wells, Mike L., McCollough, Cynthia H. , Marcus, Roy P, Enders, Felicity T, McCollough, Cynthia H , Fletcher, Joel G , Leng, Shuai , Enders, Felicity

Radiology | August 7, 2018 | Volume: 289 | Issue: 2 | Pages: 436-442

10.1148/radiol.2018180126 Get It

Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon counting detector CT system
Zhou, Wei , Montoya, Juan , Gutjahr, Ralf , Ferrero, Andrea , Halaweish, A., Kappler, S. , Halaweish, A., McCollough, Cynthia H. , Leng, Shuai , Zhou, Wei

SPIE Proceedings | March 9, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101323Q

10.1117/12.2255736 Get It

Ultra-high spatial resolution multi-energy CT using photon counting detector technology
Gutjahr, Ralf , Ferrero, Andrea , Kappler, S. , Henning, André , Halaweish, A., Zhou, Wei , Montoya, Juan , Leng, Shuai , Halaweish, A., McCollough, Cynthia H. , Zhou, Wei

SPIE Proceedings | March 9, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101320Y

10.1117/12.2255589 Get It

Renal stone characterization using high resolution imaging mode on a photon counting detector CT system
Ferrero, Andrea , Gutjahr, Ralf , Henning, André , Kappler, S. , Halaweish, A., Abdurakhimova, Dilbar, Peterson, Zhane, Montoya, Juan , McCollough, C, Halaweish, A., Leng, Shuai

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101323J

10.1117/12.2255651 Get It

Dual energy CT kidney stone differentiation in photon counting computed tomography
Gutjahr, Ralf , Polster, Christoph, Henning, André , Kappler, S. , Sedlmair, Martin , Schmidt, Bernhard , Krauß, Bernhard , Flohr, Thomas , Leng, Shuai , McCollough, Cynthia H.

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 1013237

10.1117/12.2252021 Get It

Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array
Yu, Zhicong , Jorgensen, Steven M., Li, Zhoubo , Gutjahr, Ralf , Chen, Baiyu , Halaweish, Ahmed F., Kappler, S. , Yu, Lifeng , Ritman, Erik L., Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H.

Physics in Medicine & Biology | February 2, 2016 | Volume: 61 | Issue: 4 | Pages: 1572-1595

10.1088/0031-9155/61/4/1572 Get It

Abstract This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x-ray photon flux.
Human Imaging With Photon Counting–Based Computed Tomography at Clinical Dose Levels
Gutjahr, Ralf , Halaweish, Ahmed F., Yu, Zhicong , Yu, Lifeng , Li, Zhoubo , Jorgensen, Steven M., Ritman, Erik L., Kappler, S. , Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H.

Investigative Radiology | January 27, 2016 | Volume: 51 | Issue: 7 | Pages: 421-429

10.1097/rli.0000000000000251 Get It

Objectives The purpose of this work was to measure and compare the iodine contrast-to-noise ratio (CNR) between a commercial energy-integrating detector (EID) computed tomography (CT) system and a photon-counting detector (PCD) CT scanner capable of human imaging at clinical dose rates, as well as to determine clinical feasibility using human cadavers. Materials and Methods A research dual-source PCD-CT scanner was used, where the “A” tube/detector subsystem used an EID and the “B” tube/detector subsystem used a PCD. Iodine CNR was measured in 4 anthropomorphic phantoms, simulating 4 patient sizes, at 4 tube potential settings. After biospecimen committee approval, PCD scans were performed on a fresh-frozen human head and a whole-body cadaver using clinical dose rates. Scans were repeated using the EID and identical parameters, and qualitative side-by-side comparisons were performed. Results For the same photon fluence, phantom measurements demonstrated a mean increase in CNR of 11%, 23%, 31%, 38% for the PCD system, relative to the EID system, at 80, 100, 120, and 140 kV, respectively. Photon-counting detector CT additionally provided energy-selective imaging, where low- and high-energy images reflected the energy dependence of the iodine signal. Photon-counting detector images of cadaveric anatomy demonstrated decreased beam hardening and calcium blooming in the high-energy bin images and increased contrast in the low-energy bins images relative to the EID images. Threshold-based PCD images were qualitatively deemed equivalent in other aspects. Conclusions The evaluated research PCD-CT system was capable of clinical levels of image quality at clinical dose rates. It further provided improved CNR relative to state-of-the-art EID-CT. The energy-selective bin images provide further opportunity for dual-energy and multienergy analyses.