Due to increasingly nuanced Crohn disease therapy selection and disease evaluation, radiologic assessment of transmural healing, although aspirational, may be more complete than endoscopic assessment of mucosal healing, which is the current treatment target.
Clinical benefits and current challenges of photon-counting detector CT in vascular imaging
Abstract Photon-counting detector CT (PCD-CT) directly detects individual photons and measures their energies, enabling the acquisition of multi-energy data from a single x-ray source with higher spatial resolution, thereby allowing visualization of smaller arteries and veins and other important imaging features not seen at conventional CT. It also substantially reduces calcium and stent blooming artifacts. Appropriate patient selection and task-based optimization of acquisition, reconstruction, and interpretation are critical to realize these benefits. Vascular imaging examinations for which early evidence shows that PCD-CT demonstrates higher diagnostic performance compared to conventional CT include coronary CT angiography (CTA) for evaluation of partially calcified plaques or stents, peripheral runoff CTA, detection of cerebrospinal fluid-venous fistulas, and head CTA for evaluation of small intracranial vessels and aneurysms. Current limitations include excessive image noise with the sharpest reconstruction kernels and challenges when adapting conventional CT protocols (eg, requiring sharper kernels, thinner slices, higher matrices, tailored scan modes) to achieve time-efficient image reconstruction and hanging protocols. New solutions and directions will include deep-learning-based image noise reduction, improved spectral separation, strategic triage of specific patient populations to PCD-CT systems, and subspecialty clinical practice recommendations for this new technology.
Ustekinumab for ileal stricturing Crohn’s disease—an international multicenter retrospective cohort study
Abstract Background & Aims Stricturing Crohn’s disease (CD) is a significant problem, and no selective anti-fibrotic therapies are available. Anti-inflammatory approaches are the mainstay of medical treatment. However, data on the efficacy of ustekinumab (USTE) in ileal stricturing CD are lacking. Our aim was to assess its efficacy in this setting. Methods We performed an international multicenter observational cohort study evaluating adult CD patients who received USTE within 6 months of imaging-confirmed symptomatic stricturing small bowel disease. Outcomes were rates of endoscopic balloon dilation (EBD), surgery, intervention (defined as the composite need for EBD or surgery), recurrent obstructive symptoms, and USTE persistence. Results Fifty-seven patients were included (51% female, median age 43 years). Median follow-up was 17 months. Intervention rates were 35%, 45%, and 69% of patients, at 12, 24, and 48 months, respectively. USTE persistence was 78%, 76%, and 52% at 12, 24, and 48 months. Estimated obstructive symptoms rates were 31% and 49% at 12 and 24 months, respectively. EBD within 6 months prior to starting USTE was associated with an increased risk of intervention. Increased bowel wall thickness on imaging, prior biologic use, and obstructive symptom duration were associated with USTE discontinuation. Occurrence of obstructive symptoms during treatment was associated with prior biologic use, EBD within 6 months of starting USTE, and a lower BMI. Conclusions USTE appears to be an appropriate medical option in biologic-experienced CD patients with ileal strictures. Further prospective data are needed to better define outcomes and predictors of response in this setting.
International consensus on the use of intestinal ultrasound in inflammatory bowel disease trials
Abstract Background and Aims Intestinal ultrasound (IUS) is increasingly used to monitor treatment efficacy in inflammatory bowel disease (IBD) trials. However, standardized definitions for response, remission, and optimal assessment timing remain undefined. An international expert consensus meeting was held to establish IUS endpoints for clinical trials. Methods A panel of 35 international gastroenterologists and radiologists participated in a modified Delphi process, reviewing the literature and developing consensus statements. Agreement was defined as at least 75% consensus. Results Consensus was reached on 150 statements across four domains: general IBD (30 statements), luminal Crohn’s disease (CD) (43), perianal CD (51), and ulcerative colitis (UC) (26). For luminal CD and UC, ultrasound response was defined by: (1) a ≥25% reduction in bowel wall thickness (BWT) from baseline, or (2) multifactorial improvement, combining BWT reduction with ≥1 grade decrease in color Doppler signal (CDS) or another IUS parameter. Assessments were set at weeks 4-8 for the colon and week 12 for the terminal ileum. Ultrasound remission in luminal CD was defined as: (1) BWT normalization (≤3 mm) or (2) normalization of multiple parameters, including BWT, CDS, and all other IUS parameters. Similar remission criteria were proposed for UC, but the sigmoid BWT normal range (3-4 mm) remained uncertain. The bowel ultrasound score (BUSS) for CD and the Milan ultrasound criteria (MUC) for UC were supported as standardized scoring systems for trials. Conclusion This consensus provides standardized IUS definitions to enhance consistency in IBD trials, supporting the integration of IUS in future research.
SAR Consensus Recommendations for Defining Small Bowel Crohn Disease Strictures at CT and MR Enterography
This consensus by the Society of Abdominal Radiology Inflammatory Bowel Disease Disease Focused Panel provides an updated imaging-based definition of small bowel Crohn disease stricture for CT and MR enterography.
Mucinous Appendiceal Neoplasms and Pseudomyxoma Peritonei: Imaging Features and Current Therapies
Radiologists are integral members of the interdisciplinary team for patients with mucinous appendiceal neoplasms and can directly affect care by suggesting the diagnosis of pseudomyxoma peritonei, optimizing imaging protocols for evaluating peritoneal implants, and reporting the primary tumor and spilled tumor cells thoroughly.
Feasibility of thin-slice, low noise images created using multi-kernel synthesis to replace multiple image series in head CT
Background SynthesiZed Improved Resolution and Concurrent nOise reductioN (ZIRCON) is a multi-kernel synthesis method that creates a single series of thin-slice computed tomography (CT) images displaying low noise and high spatial resolution, increasing reader efficiency and minimizing partial volume averaging. Purpose To compare the diagnostic performance of a single set of ZIRCON images to two routine clinical image series using conventional CT head and bone reconstruction kernels for diagnosing intracranial findings and fractures in patients with trauma or suspected acute neurologic deficit. Material and Methods In total, 50 patients underwent clinically indicated head CT in the ER (15 normal, 35 abnormal cases). A non-reader neuroradiologist established the reference standard. Three neuroradiologists reviewed two routine clinical series (head and bone kernels) and a single ZIRCON series, detecting intracranial findings or fractures and rating confidence (0–100). Sensitivity, specificity, and jackknife free-response receiver operating characteristic (JAFROC) figure of merit (FOM) were compared (limit of non-inferiority: −0.10). Results ZIRCON and conventional images demonstrated comparable performance for fractures (sensitivity: 51.5% vs. 54.5%; specificity: 40.2% vs. 34.2%) and intracranial findings (sensitivity: 88.2% vs. 91.4%; specificity: 77.2% vs. 73.7%).The estimated difference of JAFROC FOM demonstrated ZIRCON non-inferiority for acute pathologies overall (0.003 [95% CI=−0.051–0.057]) and fractures (0.048 [95% CI=−0.050–0.145]) but not for intracranial findings alone (−0.024 [95% CI=−0.100–0.052]). Conclusion Thin-slice, low noise, and high spatial resolution images can be created to display intracranial findings and fractures replacing multiple images series in head CT with similar performance. Future studies in more patients and further algorithmic development are warranted.
Photon-counting CT in Thoracic Imaging: Early Clinical Evidence and Incorporation Into Clinical Practice