Back to Authors

Rajiah, Prabhakar Shantha

Mayo Clinic

Department of Radiology, Mayo Clinic, Rochester, Minnesota.

Citations 8

Clinical benefits and current challenges of photon-counting detector CT in vascular imaging
Sadaney, Ahmed O El , Mark, Ian, Froemming, Adam T. , Baffour, Francis , Yu, Lifeng, Leng, Shuai, McCollough, Cynthia H, Leng, Shuai , El Sadaney, Ahmed O , Rajiah, Prabhakar Shantha, Campeau, Norbert G , Froemming, Adam T , Baffour, Francis I , Horst, Kelly K. , Yu, Lifeng , Leng, Shuai , McCollough, Cynthia H , Fletcher, Joel G , Diehn, Felix E. , Rajiah, Prabhakar , Mark, Ian, Campeau, Norbert G. , McCollough, Cynthia H. , Fletcher, Joel G.

Radiology Advances | April 14, 2026 | Volume: 3 | Issue: 3 | Pages: No page available

10.1093/radadv/umag021 Get It

Abstract Photon-counting detector CT (PCD-CT) directly detects individual photons and measures their energies, enabling the acquisition of multi-energy data from a single x-ray source with higher spatial resolution, thereby allowing visualization of smaller arteries and veins and other important imaging features not seen at conventional CT. It also substantially reduces calcium and stent blooming artifacts. Appropriate patient selection and task-based optimization of acquisition, reconstruction, and interpretation are critical to realize these benefits. Vascular imaging examinations for which early evidence shows that PCD-CT demonstrates higher diagnostic performance compared to conventional CT include coronary CT angiography (CTA) for evaluation of partially calcified plaques or stents, peripheral runoff CTA, detection of cerebrospinal fluid-venous fistulas, and head CTA for evaluation of small intracranial vessels and aneurysms. Current limitations include excessive image noise with the sharpest reconstruction kernels and challenges when adapting conventional CT protocols (eg, requiring sharper kernels, thinner slices, higher matrices, tailored scan modes) to achieve time-efficient image reconstruction and hanging protocols. New solutions and directions will include deep-learning-based image noise reduction, improved spectral separation, strategic triage of specific patient populations to PCD-CT systems, and subspecialty clinical practice recommendations for this new technology.
Learned high resolution energy‐integrating detector CT angiography: Harnessing the power of ultra‐high‐resolution photon counting detector CT
Koons, Emily K. , Chang, Shaojie , Missert, Andrew D., Gong, Hao , Thorne, Jamison E. , Hoodeshenas, Safa , McCollough, C, Leng, Shuai, Rajiah, Prabhakar Shantha, Missert, Andrew D., Rajiah, Prabhakar , Leng, Shuai

Medical Physics | May 8, 2025 | Volume: 52 | Issue: 7 | Pages: No page available

10.1002/mp.17874 Get It

Abstract Background Coronary computed tomography angiography (cCTA) is a widely used noninvasive diagnostic exam to assess patients for coronary artery disease (CAD). However, the spatial resolution of most CT scanners is limited due to the use of energy‐integrating detectors (EIDs). Purpose To develop a convolutional neural network ( I mproved LUMEN visualization through A rtificial super‐resolu T ion imag E s (ILUMENATE)) informed by photon‐counting‐detector (PCD)‐CT to improve EID‐CT image resolution and determine its impact on cCTA. Materials and methods With IRB approval, 30 patients undergoing clinically indicated cCTA were scanned with EID‐CT (SOMATOM Force, Siemens Healthineers, Forchheim, Germany) and subsequently with ultra‐high‐resolution (UHR) PCD‐CT (NAEOTOM Alpha, Siemens Healthineers) on the same day. ILUMENATE was trained on eight patient PCD‐CT datasets (67,890 patch pairs with 90% for training (61,101), 10% reserved for validation (6,789)) and applied to 22 unseen EID‐CT cases. Spatial resolution was evaluated using line profiles and percent diameter stenosis quantified with a severity score assigned. Two experienced radiologists, blinded to image type, selected preferred series and scored images for overall quality, sharpness, and noise comparing original EID‐CT and ILUMENATE output. Results Visual assessment and line profiles showed substantial resolution improvement with ILUMENATE. Percent diameter stenosis was significantly reduced (mean ± standard deviation: 4.42% ± 4.82%) using ILUMENATE ( p < 0.001) with nine lesions shifting down in severity score. Readers preferred ILUMENATE images in 22/22 cases and scored ILUMENATE superiorly for overall quality, sharpness, and noise ( p < 0.05). Conclusions ILUMENATE enhanced image resolution, resulting in improved overall image quality, reduced calcium blooming artifacts, and improved lumen visibility in cCTA exams performed using EID‐CT. This could potentially allow for improved accessibility to UHR image quality, allowing for more accurate assessment of CAD.
Quantitative CT imaging: where are we, and what is missing?
Treb, Kevin , Sadaney, Ahmed O El , Ferrero, Andrea , Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H. , Rajendran, Kishore , Treb, Kevin J, El Sadaney, Ahmed O , Leng, Shuai , Yu, Lifeng , Rajiah, Prabhakar Shantha, McCollough, Cynthia H , Rajendran, Kishore , Treb, Kevin , Baffour, Francis , Rajiah, Prabhakar , Fletcher, Joel G.

British Journal of Radiology | April 7, 2025 | Volume: 98 | Issue: 1175 | Pages: 1834-1842

10.1093/bjr/tqaf075 Get It

Abstract Quantitative computed tomography (CT) enables the measurement of biophysical processes characterized by morphology, composition, flow, and/or motion to aid in clinical diagnosis and intervention. Since its initial application for determining bone mineral density for skeletal fragility assessment, quantitative CT has continued to evolve alongside CT’s technological advancements. A key challenge facing quantitative CT is the lack of standardization pertinent to image acquisition, reconstruction, and image analysis. With the introduction of spectral CT involving dual-energy approaches and photon-counting detectors (PCD), we are now able to obtain detailed information regarding mass densities of endogenous and exogeneous materials. Furthermore, energy-resolved CT yields spectral image types (eg, virtual monoenergetic image) that are, in principle, independent of tube potential and patient size. This paves the way for workflow standardization and helps improve the consistency and reproducibility of CT-derived measurements. In this article, we review clinical applications of quantitative CT, discuss key challenges associated with quantitative CT and its adoption into routine practice, and outline the unique benefits ushered by new CT technologies such as PCD-CT towards improving quantitative imaging.
Training and Verification Requirements for Interpretation of Cardiac CT and MRI: AJR Expert Panel Narrative Review
Morris, Michael F. , Ocazionez-Trujillo, Daniel , Ordovás, Karen , Ranganath, Praveen , Vargas, Daniel , Woodard, Pamela K. , Choi, Andrew , Rajiah, Prabhakar Shantha, Rajiah, Prabhakar , Budoff, Matthew J. , Ghoshhajra, Brian , Patel, Amit R.

American Journal of Roentgenology | July 10, 2024 | Volume: 224 | Issue: 3 | Pages: No page available

10.2214/ajr.24.31524 Get It

Photon-counting CT in Thoracic Imaging: Early Clinical Evidence and Incorporation Into Clinical Practice
Fletcher, Joel G. , Bratt, Alex , Horst, Kelly K. , Koo, Chi Wan , Baffour, Francis , Ko, Jane P. , Rémy‐Jardin, Martine , McCollough, Cynthia H. , Yu, Lifeng , Bratt, Alex , Horst, Kelly , Koo, Chi Wan , Rajiah, Prabhakar Shantha, Baffour, Francis I , Remy-Jardin, Martine , McCollough, Cynthia H , Yu, Lifeng , Fletcher, Joel G , Inoue, Akitoshi , Rajiah, Prabhakar

Radiology | March 19, 2024 | Volume: 310 | Issue: 3 | Pages: No page available

10.1148/radiol.231986 Get It

Infrapopliteal Segments on Lower Extremity CTA: Prospective Intraindividual Comparison of Energy-Integrating Detector CT and Photon-Counting Detector CT
Yalon, Mariana , Thorne, Jamison E. , Lee, Yong S. , Johnson, Matthew P. , Esquivel, Andrea , Rajiah, Prabhakar Shantha, Inoue, Akitoshi , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Rajiah, Prabhakar

American Journal of Roentgenology | December 20, 2023 | Volume: 222 | Issue: 3 | Pages: No page available

10.2214/ajr.23.29778 Get It

Imaging of Cardiac Fibrosis: An Update, From the AJR Special Series on Imaging of Fibrosis
Karur, Gauri Rani , Aneja, Ashish , Stojanovska, Jadranka , Hanneman, Kate , Latchamsetty, Rakesh , Kersting, David , Rajiah, Prabhakar Shantha, Hanneman, Kate , Rajiah, Prabhakar

American Journal of Roentgenology | September 27, 2023 | Volume: 222 | Issue: 6 | Pages: No page available

10.2214/ajr.23.29870 Get It

Myocarditis Mimicking Stress-Induced (Takotsubo) Cardiomyopathy
Canan, Arzu , Woerkom, Ryan C. Van , Rajiah, Prabhakar , Rajiah, Prabhakar Shantha, Rajiah, Prabhakar

Texas Heart Institute Journal | December 9, 2022 | Volume: 49 | Issue: 6 | Pages: No page available

10.14503/thij-20-7430 Get It