Abstract Photon-counting detector CT (PCD-CT) directly detects individual photons and measures their energies, enabling the acquisition of multi-energy data from a single x-ray source with higher spatial resolution, thereby allowing visualization of smaller arteries and veins and other important imaging features not seen at conventional CT. It also substantially reduces calcium and stent blooming artifacts. Appropriate patient selection and task-based optimization of acquisition, reconstruction, and interpretation are critical to realize these benefits. Vascular imaging examinations for which early evidence shows that PCD-CT demonstrates higher diagnostic performance compared to conventional CT include coronary CT angiography (CTA) for evaluation of partially calcified plaques or stents, peripheral runoff CTA, detection of cerebrospinal fluid-venous fistulas, and head CTA for evaluation of small intracranial vessels and aneurysms. Current limitations include excessive image noise with the sharpest reconstruction kernels and challenges when adapting conventional CT protocols (eg, requiring sharper kernels, thinner slices, higher matrices, tailored scan modes) to achieve time-efficient image reconstruction and hanging protocols. New solutions and directions will include deep-learning-based image noise reduction, improved spectral separation, strategic triage of specific patient populations to PCD-CT systems, and subspecialty clinical practice recommendations for this new technology.
Pushing the limits of spatial resolution in clinical PCD‐CT using a dedicated high‐resolution convolutional neural network (HR‐CNN)
Abstract Background Photon‐counting‐detector (PCD) CT systems offer ultra‐high spatial resolution, yet the visual spatial resolution on clinical images often constrained by large pixel size, yielding resolutions below system capabilities. While reducing pixel size and using sharp kernels enhance visual spatial resolution, it increases noise, compromising image quality. Purpose To investigate the combined effects of pixel size and reconstruction kernels on visual spatial resolution using phantom and clinical images and to develop a dedicated high‐resolution deep convolutional neural network (HR‐CNN) to better utilize the intrinsic high spatial resolution of PCD‐CT in clinical imaging. Methods The relationship between spatial resolution, reconstruction kernel, and pixel size was investigated to identify strategies for utilizing the full spatial resolution potential of PCD‐CT. To overcome the increased noise associated with high‐resolution settings, a dedicated HR‐CNN was developed to push the limit of spatial resolution in routine PCD‐CT exams. The HR‐CNN was trained using patient exams acquired with ultra‐high‐resolution (UHR) mode and reconstructed with a 150‐mm field of view (FOV), matrix size of 1024×1024 (0.15‐mm pixel size) and sharpest quantitative kernel (Qr89). The impact of FOV, kernel, and denoising on spatial resolution was studied using bar‐pattern phantoms and a pilot clinical evaluation including 5 patients with interstitial lung diseases. Two thoracic radiologists evaluated 4 different FOV/reconstruction conditions: (1) FOV‐410/Qr56‐Iterative reconstruction (IR), (2) FOV‐410/Qr89‐IR, (3) FOV‐150/Qr89‐IR, and (4) FOV‐150/Qr89‐HR‐CNN in terms of overall image quality, noise, visual spatial resolution, and overall preference. Results With a FOV of 410 mm, the Qr89 sharp kernel displayed bar‐patterns up to 14 lp/cm, not much higher than the routine lung kernel Qr56. When the FOV was reduced to 150 mm, Qr89‐IR allowed for the visualization of line pair patterns ranging from 18 to 20 lp/cm, with 20 lp/cm being moderately discernible. The application of Qr89‐HR‐CNN yielded further improvement, enabling the display of line pair patterns as high as 20–22 lp/cm. In patient cases, both radiologists consistently ranked the FOV‐150 images processed with HR‐CNN as superior across metrics including overall image quality, noise reduction, visual spatial resolution, and overall preference. The HR‐CNN reduced the noise in patients’ images by 93.0 ± 0.6% and 44.9 ± 5.3% in comparison with the original FBP and IR images, respectively. Conclusions The spatial resolution of PCD‐CT is not maximized in routine practice due to the large FOV and high noise levels at sharp kernels. The proposed HR‐CNN denoising method, along with small pixel size, may allow the high spatial resolution toward the system limit to be implemented in practice, which is beneficial in the diagnosis of many diseases, including interstitial lung disease.
Agentic AI and Large Language Models in Radiology: Opportunities and Hallucination Challenges
The field of radiology is experiencing rapid adoption of large language models (LLMs), yet their tendency to generate hallucinations (plausible but incorrect information) remains a significant barrier to trust. This comprehensive review evaluates emerging agentic artificial intelligence (AI) approaches, including multi-agent role-based systems, retrieval-augmented generation (RAG), and uncertainty quantification, to assess their potential for reducing hallucinations in radiology workflows. Evidence from 2024 to 2025 demonstrates that agentic AI can improve diagnostic accuracy and reduce error rates, though these methods remain computationally demanding and lack comprehensive clinical validation. Multi-agent frameworks enable cross-validation through role-based specialization and systematic workflow orchestration, while RAG strategies enhance accuracy by grounding responses in verified medical literature. Within multi-agent systems, uncertainty quantification enables agents to communicate confidence levels to one another, allowing them to appropriately weigh each other’s contributions during collaborative analysis. While multi-agent frameworks and RAG strategies show significant promise, practical deployment will require careful integration with human oversight, robust evaluation metrics tailored to medical imaging tasks, and regulatory adaptation to ensure safe clinical use in diverse patient populations and imaging modalities.
Reduced-Dose Chest CTA for the Detection of Pulmonary Arteriovenous Malformations in Pediatric Patients With Hereditary Hemorrhagic Telangiectasia
Objectives: To determine the feasibility of reduced-dose chest computed tomographic angiography (CTA) with convolutional neural network (CNN) denoising for detecting pulmonary arteriovenous malformations (pAVMs) in children with hereditary hemorrhagic telangiectasia (cwHHT). Methods: Fifteen cwHHT underwent a chest CTA (ie, a controlled “study” dose). Noise was inserted to simulate a quarter dose (QD) exam. Images were reconstructed using iterative reconstruction (IR) and our self-trained CNN denoising model. For each case, 3 sets of images were created: study dose (SD)+IR, QD+IR, and QD+CNN. Two thoracic radiologists independently scored each set to assess quality, spatial resolution, artifacts, and the presence of pAVMs using 4-level ordinal scales. Quantitative assessments of image quality were performed using contrast-to-noise ratios (CNRs) with comparisons made between the experimental conditions. Results: Thirteen of the 15 patients recruited with hereditary hemorrhagic telangiectasia (mean age: 9.3±4.5 y) were positive for pAVM by transthoracic contrast echocardiography. The sensitivities using QD+CNN were 0.85 and 1.00 for readers 1 and 2, respectively. This was compared with 0.69 and 0.84 using QD+IR versus 0.85 and 0.92 for SD+IR. Inter-reader agreement for pAVM detection utilizing QD+CNN was moderate and resulted in kappa=0.59 ( P =0.012). The subjective assessments for QD+CNN were comparable to the SD technique. Regression analysis of reader scores revealed improved quality in QD+CNN versus QD+IR ( P =0.001). Similarly, the QD+CNN condition demonstrated the highest CNRs. Conclusions: Reduced-dose chest CTA with CNN denoising provides a level of sensitivity comparable to standard dose CTA and high CNRs for the detection of pAVMs in cwHHT.
Wilms Tumor, Version 2.2025, NCCN Clinical Practice Guidelines In Oncology
The NCCN Clinical Practice Guidelines (NCCN Guidelines) for Wilms Tumor (WT; nephroblastoma) cover strategies for the screening, diagnosis, and treatment of WT, which is the most frequent primary kidney tumor in children. WT can generally be separated into 2 histology types: favorable histology WT and anaplastic WT. Five-year survival is high for children with favorable histology WT who receive appropriate treatment; however, survival rates are much lower for patients who present with higher stage diffuse anaplastic WT. Treatment of WT can range from surgery alone to surgery plus intensive chemotherapy and radiation depending on whether the tumor is unilateral or bilateral, histology, and local stage. The goal of therapy is to maximize cure while minimizing long-term toxicities. The content featured in this issue covers the NCCN panel’s recommendations for overall management of both favorable histology WT and anaplastic WT.
Photon-counting detector CT in paediatric imaging: a review of current literature and future directions
Abstract The benefits of photon-counting detector (PCD) CT include improved spatial resolution, increased radiation dose efficiency, and the elimination of electronic noise. Unlike traditional energy-integrating-detector (EID) CT systems, PCDs have inherent spectral capabilities, which support “always-on” dual energy and multi-energy imaging acquisition. PCD-CT directly converts X-ray photons into electrical signals and captures their individual energy levels. Current commercially available PCD-CT scanners, all from one manufacturer, include 2 models that incorporate dual-source geometry. This innovation is particularly advantageous for paediatric imaging by enabling rapid scans that reduce motion artifact and therefore the need for sedation and can now be combined in the current model with multi-energy imaging or ultra-high-resolution acquisition. This review article explores how the technical benefits of PCD CT improve the diagnostic quality of images and opens the field of paediatric radiology up to future opportunities for research and new applications.
Contrast Media in Children: Ten Important Concepts on Administration, Applications, Complications, and Environmental Considerations, From the
AJR
Special Series on Contrast Media
This article addresses clinical challenges of photon-counting detector (PCD) CT in pediatric patients by outlining fundamental terminology, explaining technical aspects, and providing protocol guidance for the first commercially available PCD CT scanner.
The Acute Abdomen: A Case-based Survival Guide to What the Surgeon Wants to Know