Objectives: To determine the feasibility of reduced-dose chest computed tomographic angiography (CTA) with convolutional neural network (CNN) denoising for detecting pulmonary arteriovenous malformations (pAVMs) in children with hereditary hemorrhagic telangiectasia (cwHHT). Methods: Fifteen cwHHT underwent a chest CTA (ie, a controlled “study” dose). Noise was inserted to simulate a quarter dose (QD) exam. Images were reconstructed using iterative reconstruction (IR) and our self-trained CNN denoising model. For each case, 3 sets of images were created: study dose (SD)+IR, QD+IR, and QD+CNN. Two thoracic radiologists independently scored each set to assess quality, spatial resolution, artifacts, and the presence of pAVMs using 4-level ordinal scales. Quantitative assessments of image quality were performed using contrast-to-noise ratios (CNRs) with comparisons made between the experimental conditions. Results: Thirteen of the 15 patients recruited with hereditary hemorrhagic telangiectasia (mean age: 9.3±4.5 y) were positive for pAVM by transthoracic contrast echocardiography. The sensitivities using QD+CNN were 0.85 and 1.00 for readers 1 and 2, respectively. This was compared with 0.69 and 0.84 using QD+IR versus 0.85 and 0.92 for SD+IR. Inter-reader agreement for pAVM detection utilizing QD+CNN was moderate and resulted in kappa=0.59 ( P =0.012). The subjective assessments for QD+CNN were comparable to the SD technique. Regression analysis of reader scores revealed improved quality in QD+CNN versus QD+IR ( P =0.001). Similarly, the QD+CNN condition demonstrated the highest CNRs. Conclusions: Reduced-dose chest CTA with CNN denoising provides a level of sensitivity comparable to standard dose CTA and high CNRs for the detection of pAVMs in cwHHT.
High-Pitch Multienergy Coronary CT Angiography in Dual-Source Photon-Counting Detector CT Scanner at Low Iodinated Contrast Dose
Objectives The aim of this study was to evaluate the high-helical pitch, multienergy (ME) scanning mode of a clinical dual-source photon-counting detector (PCD) computed tomography (CT) and the benefit of virtual monoenergetic images (VMIs) for low-contrast-dose coronary CT angiography (CTA). Materials and Methods High-pitch (3.2) ME coronary CTA was performed in PCD-CT in 27 patients using low contrast dose (30 mL of iohexol 350 mg/mL) and in 26 patients at routine contrast dose (60 mL). Low-energy-threshold 120 kV images (also known as T3D images) and 50 kiloelectron volts (50 keV) and 100 kiloelectron volts (100 keV) VMIs were reconstructed using a 1024 × 1024 matrix and 0.6-mm slices. The CT numbers, noise, and contrast-to-noise ratio (CNR) were measured in the ascending aorta (AA), left main coronary artery (LMCA), and distal left anterior descending (LAD) artery. Confidence in grading luminal stenosis with calcific plaque, noncalcific plaque, and stent was evaluated by 2 independent readers on a 0–100 scale (0 the lowest), and a CAD-RADS score was assigned. Image contrast enhancement, sharpness, noise, artifacts, and overall image quality were rated using a 5-point ordinal scale (1 the lowest). Results The radiation doses (CTDI) in low- and routine-contrast cohorts were 2.5 ± 0.6 mGy and 3.1 ± 1.7 mGy, respectively ( P = 0.12). At all measured locations, the mean CT number was >300 HU in 120 kV (LMCA 382.9 ± 76.2, distal LAD 341.0 ± 53.9, AA 399.5 ± 76.1) and 50 keV images (LMCA 667.5 ± 139.9, distal LAD 578.1 ± 121.5, AA 700.8 ± 142.5) in the low-contrast cohort, with a 96% increase in CT numbers for 50 keV over 120 kV. The CT numbers were significantly higher ( P < 0.0001) in 50 keV than 120 kV and 100 keV VMI. The CNR was also significantly ( P < 0.0001) higher in 50 keV than 120 kV and 100 keV images in all vessels. Confidence in the assessment of luminal stenosis in the presence of calcific plaque was significantly higher ( P = 0.001) with the addition of 100 keV VMI (median score, 100) than using 50 keV alone (median score, 70) and 120 kV (median score, 70) for reader 1, but no significant differences were seen for reader 2 who had same median scores of 100 for all image types. The confidence in the assessment of luminal stenosis within a stent improved with the use of 100 keV images for both readers (reader 1: median scores for 50 + 100 keV = 100, 50 keV = 82.5, 120 kV = 82.5; reader 2: 50 + 100 keV = 100, 50 keV = 90, 120 kV = 90). There were no significant differences in confidence scores for assessment of luminal stenosis from noncalcific plaques for both readers. The reader-averaged qualitative scores for vascular enhancement and overall image quality were significantly higher for 50 keV VMI than for 120 kV images in both low- and routine-contrast dose cohorts. The image sharpness was nonsignificantly higher at 50 keV VMI than 120 kV images, and the artifact score was comparable for 50 keV VMI and 120 kV images. The noise was higher in 50 keV VMI than in 120 kV images. Conclusions High-pitch ME PCD-CT mode produced diagnostic quality coronary CTA images at low radiation and iodinated contrast doses. The availability of ME VMIs significantly improved the CNR, overall image quality, and confidence in assessment of luminal stenosis in the presence of calcific plaques and stents, and resulted in change of CAD-RADS categories in 9 patients.
A rare presentation of unilateral periureteral renal lymphangiomatosis
Renal lymphangiomatosis is a rare developmental malformation of the perirenal lymphatic system. We report a unique case with unilateral massive periureteral involvement in addition to intrarenal and peripelvic lymphangiomatosis. Although this is a rare entity, it should be considered in patients with peripelvic or periureteric cystic lesions as it may affect appropriate management and follow-up. This case report reviews the imaging features of this entity and a comprehensive literature review and discussion about the entity will be provided.
Testicular cavernous hemangioma masquerading as testicular malignancy
AbstractThere is a lack of understanding in the performance of flexible noise control (FNC) processing, which is used in digital radiography on a scanner vendor and has four parameters each involving multiple options. The aim of this study was to investigate the impact of FNC on portable chest imaging. An anthropomorphic chest phantom was imaged using a clinical chest program with 85 kV and five radiation dose levels at 40″ source‐to‐image distance with software‐based scatter reduction method. All images were processed without and with FNC. Noise analysis was performed in two regions of interest (ROI) on subtracted noise‐only images, and line profiles were generated through a lung‐rib interface. In addition, noise power spectra (NPS) analysis was performed in solid water phantoms of 10 and 20 cm thicknesses, using the same acquisition program and a range of dose levels. Last, feedback on retrospectively deidentified, reprocessed, and randomized clinical images from 20 portable chest exams was gathered from two thoracic radiologists. Noise reduction performances of FNC were demonstrated, with the level depending on specific FNC parameters, dose levels, ROI placement, and phantom sizes. Higher frequency textural patterns were revealed through the NPS analysis, which varied based on FNC parameters, dose levels, and phantom sizes. Overall, the vendor default parameter FGA0.5 yielded the highest noise reduction and textural artifacts. Radiologist feedback showed consistent preference of no FNC due to the presence of textural artifacts in the FNC‐processed images. An algorithm improvement to avoid introducing artifacts would be desired.
Pulmonary Artery Dissection: A Fatal Complication of Pulmonary Artery Aneurysm
Coronavirus disease 2019 (COVID-19) was initially recognized in late December 2019 and has quickly spread globally with over 114 million reported cases worldwide at the time of this publication. For the majority of patients infected with COVID-19, the clinical manifestations are absent or mild. In more advanced cases, severe respiratory dysfunction is the leading cause of morbidity and mortality. However, increasingly, there have been reports of increased thrombotic complications including pulmonary embolism and deep vein thrombosis seen in these patients. We present herein a series of cases of concomitant COVID-19 pneumonia and venous thromboembolism. These cases highlight the importance of clinical and radiologic vigilance to ensure this often clinically silent complication is not missed.