Back to Authors

Baffour, Francis I

0000-0001-8005-4823

Mayo Clinic

Department of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.

Citations 13

Complementary Role of Whole-Body MRI and CT in Hematologic Malignancies and Bone Marrow Disorders
Ghotbi, Elena, Frick, Matthew, Cook, Joselle, Baffour, Francis , Baffour, Francis I , Frick, Matthew J. , Cook, Joselle

Journal of Computer Assisted Tomography | July 22, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1097/rct.0000000000001918 Get It

Whole-body cross-sectional imaging has largely replaced skeletal survey as the standard for evaluating hematologic malignancies and bone marrow disorders, but the practical choice between whole-body low-dose CT (WBCT) and whole-body MRI (WBMRI) remains incompletely resolved. This clinical review provides a practical, scenario-based comparison of WBCT and WBMRI across diagnosis, staging, treatment response, and surveillance. We emphasize real-world practical considerations, including scanner access, expertise, patient tolerance, radiation considerations, and cost. In multiple myeloma, with available comparative evidence, we include a focused research synthesis of 3 studies (152 patients) demonstrating high pooled CT-MRI concordance of 0.895 (95% CI: 0.834-0.935) with no detectable heterogeneity ( I 2 =0%), supporting either modality as a reasonable first-line depending on the clinical question. Across all included disease categories, the broader pooled concordance estimate was 0.797 (95% CI: 0.667-0.885) with substantial heterogeneity reflecting variability in clinical context, reference standard, and protocol. WBMRI dominates in non-neoplastic marrow disorders where marrow characterization is essential. In lymphoma, FDG-PET/CT remains the standard for adult disease, with WBMRI most indicated in pediatrics and adolescents. Emerging CT techniques, including dual-energy CT with virtual noncalcium images and photon-counting detector CT, are extending CT into the marrow imaging space and narrowing the historical gap with MRI. Modality selection should be guided by the specific clinical scenario, available resources, and patient factors rather than by global judgments of modality superiority.
Clinical benefits and current challenges of photon-counting detector CT in vascular imaging
Sadaney, Ahmed O El , Mark, Ian, Froemming, Adam T. , Baffour, Francis , Yu, Lifeng, Leng, Shuai, McCollough, Cynthia H, Leng, Shuai , El Sadaney, Ahmed O , Rajiah, Prabhakar Shantha, Campeau, Norbert G , Froemming, Adam T , Baffour, Francis I , Horst, Kelly K. , Yu, Lifeng , Leng, Shuai , McCollough, Cynthia H , Fletcher, Joel G , Diehn, Felix E. , Rajiah, Prabhakar , Mark, Ian, Campeau, Norbert G. , McCollough, Cynthia H. , Fletcher, Joel G.

Radiology Advances | April 14, 2026 | Volume: 3 | Issue: 3 | Pages: No page available

10.1093/radadv/umag021 Get It

Abstract Photon-counting detector CT (PCD-CT) directly detects individual photons and measures their energies, enabling the acquisition of multi-energy data from a single x-ray source with higher spatial resolution, thereby allowing visualization of smaller arteries and veins and other important imaging features not seen at conventional CT. It also substantially reduces calcium and stent blooming artifacts. Appropriate patient selection and task-based optimization of acquisition, reconstruction, and interpretation are critical to realize these benefits. Vascular imaging examinations for which early evidence shows that PCD-CT demonstrates higher diagnostic performance compared to conventional CT include coronary CT angiography (CTA) for evaluation of partially calcified plaques or stents, peripheral runoff CTA, detection of cerebrospinal fluid-venous fistulas, and head CTA for evaluation of small intracranial vessels and aneurysms. Current limitations include excessive image noise with the sharpest reconstruction kernels and challenges when adapting conventional CT protocols (eg, requiring sharper kernels, thinner slices, higher matrices, tailored scan modes) to achieve time-efficient image reconstruction and hanging protocols. New solutions and directions will include deep-learning-based image noise reduction, improved spectral separation, strategic triage of specific patient populations to PCD-CT systems, and subspecialty clinical practice recommendations for this new technology.
Photon-counting detector CT in musculoskeletal imaging: benefits and outlook
Sadaney, Ahmed O El , Ferrero, Andrea , Rajendran, Kishore , Booij, Ronald , Marcus, Roy , Sutter, Reto , Oei, E.H. , Baffour, Francis , El Sadaney, Ahmed O , Rajendran, Kishore , Baffour, Francis I

British Journal of Radiology | June 6, 2025 | Volume: 98 | Issue: 1175 | Pages: 1859-1862

10.1093/bjr/tqaf124 Get It

Abstract Photon-counting detector CT (PCD-CT) represents a significant advancement in medical imaging, particularly for musculoskeletal (MSK) applications. Its primary innovation lies in enhanced spatial resolution, which facilitates improved detection of small anatomical structures such as trabecular bone, osteophytes, and subchondral cysts. PCD-CT enables high-quality imaging with reduced radiation doses, making it especially beneficial for populations requiring frequent imaging, such as paediatric patients and individuals with multiple myeloma. Additionally, PCD-CT supports advanced applications like bone quality assessment, which correlates well with gold-standard tests, and can aid in diagnosing osteoporosis and assessing fracture risk. Techniques such as spectral shaping and virtual monoenergetic imaging further optimize the technology, minimizing artefacts and enhancing material decomposition. These capabilities extend to conditions like gout and haematologic malignancies, offering improved detection and assessment. The integration of artificial intelligence could enhance PCD-CT’s performance by reducing image noise and improving quantitative assessments. Ultimately, PCD-CT’s superior resolution, reduced dose protocols, and multi-energy imaging capabilities will likely have a transformative impact on MSK imaging, improving diagnostic accuracy, patient care, and clinical outcomes.
Photon-counting CT in Thoracic Imaging: Early Clinical Evidence and Incorporation Into Clinical Practice
Fletcher, Joel G. , Bratt, Alex , Horst, Kelly K. , Koo, Chi Wan , Baffour, Francis , Ko, Jane P. , Rémy‐Jardin, Martine , McCollough, Cynthia H. , Yu, Lifeng , Bratt, Alex , Horst, Kelly , Koo, Chi Wan , Rajiah, Prabhakar Shantha, Baffour, Francis I , Remy-Jardin, Martine , McCollough, Cynthia H , Yu, Lifeng , Fletcher, Joel G , Inoue, Akitoshi , Rajiah, Prabhakar

Radiology | March 19, 2024 | Volume: 310 | Issue: 3 | Pages: No page available

10.1148/radiol.231986 Get It

Staging of breast cancer in the breast and regional lymph nodes using contrast-enhanced photon-counting detector CT: accuracy and potential impact on patient management
Yalon, Mariana , Sae-Kho, Tiffany, Khanna, Akriti , Chang, Shaojie , Andrist, Boleyn R., Weber, Nikkole M. , Hoodeshenas, Safa , Ferrero, Andrea , Glazebrook, Katrina N. , Baffour, Francis I , Sae-Kho, Tiffany M. , McCollough, Cynthia H. , Baffour, Francis

British Journal of Radiology | January 10, 2024 | Volume: 97 | Issue: 1153 | Pages: 93-97

10.1093/bjr/tqad042 Get It

Abstract Objectives To describe the feasibility and evaluate the performance of multiphasic photon-counting detector (PCD) CT for detecting breast cancer and nodal metastases with correlative dynamic breast MRI and digital mammography as the reference standard. Methods Adult females with biopsy-proven breast cancer undergoing staging breast MRI were prospectively recruited to undergo a multiphasic PCD-CT using a 3-phase protocol: a non-contrast ultra-high-resolution (UHR) scan and 2 intravenous contrast-enhanced scans with 50 and 180 s delay. Three breast radiologists compared CT characteristics of the index malignancy, regional lymphadenopathy, and extramammary findings to MRI. Results Thirteen patients underwent both an MRI and PCD-CT (mean age: 53 years, range: 36-75 years). Eleven of thirteen cases demonstrated suspicious mass or non-mass enhancement on PCD-CT when compared to MRI. All cases with metastatic lymphadenopathy (3/3 cases) demonstrated early avid enhancement similar to the index malignancy. All cases with multifocal or multicentric disease on MRI were also identified on PCD-CT (3/3 cases), including a 4 mm suspicious satellite lesion. Four of five patients with residual suspicious post-biopsy calcifications on mammograms were detected on the UHR PCD-CT scan. Owing to increased field-of-view at PCD-CT, a 5 mm thoracic vertebral metastasis was identified at PCD-CT and not with the breast MRI. Conclusions A 3-phase PCD-CT scan protocol shows initial promising results in characterizing breast cancer and regional lymphadenopathy similar to MRI and detects microcalcifications in 80% of cases. Advances in knowledge UHR and spectral capabilities of PCD-CT may allow for comprehensive characterization of breast cancer and may represent an alternative to breast MRI in select cases.
Quantifying Uncertainty in Deep Learning of Radiologic Images
Faghani, Shahriar , Moassefi, Mana , Rouzrokh, Pouria , Khosravi, Bardia , Baffour, Francis , Ringler, Michael D. , Erickson, Bradley J. , Baffour, Francis I , Khosravi, Bardia , Erickson, Bradley J , Rouzrokh, Pouria , Faghani, Shahriar , Moassefi, Mana

Radiology | August 1, 2023 | Volume: 308 | Issue: 2 | Pages: No page available

10.1148/radiol.222217 Get It

Photon-Counting Detector CT: Key Points Radiologists Should Know
Esquivel, Andrea , Ferrero, Andrea , Mileto, Achille , Baffour, Francis , Horst, Kelly K. , Rajiah, Prabhakar , Inoue, Akitoshi , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Horst, Kelly , Rajiah, Prabhakar , McCollough, Cynthia H , Fletcher, Joel G , Leng, Shuai , Baffour, Francis I , Inoue, Akitoshi

Korean Journal of Radiology | August 10, 2022 | Volume: 23 | Issue: 9 | Pages: 854

10.3348/kjr.2022.0377 Get It

An interactive eye‐tracking system for measuring radiologists' visual fixations in volumetric CT images: Implementation and initial eye‐tracking accuracy validation
Gong, Hao , Hsieh, Scott S. , Holmes, David R. , Cook, David A. , Bartlett, David J. , Baffour, Francis , Takahashi, Hiroaki , Yu, Lifeng , Inoue, Akitoshi , Baffour, Francis I , Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H. , Fletcher, Joel G. , Takahashi, Hiroaki

Medical Physics | September 17, 2021 | Volume: 48 | Issue: 11 | Pages: 6710-6723

10.1002/mp.15219 Get It

AbstractPurposeEye‐tracking approaches have been used to understand the visual search process in radiology. However, previous eye‐tracking work in computer tomography (CT) has been limited largely to single cross‐sectional images or video playback of the reconstructed volume, which do not accurately reflect radiologists' visual search activities and their interactivity with three‐dimensional image data at a computer workstation (e.g., scroll, pan, and zoom) for visual evaluation of diagnostic imaging targets. We have developed a platform that integrates eye‐tracking hardware with in‐house‐developed reader workstation software to allow monitoring of the visual search process and reader‐image interactions in clinically relevant reader tasks. The purpose of this work is to validate the spatial accuracy of eye‐tracking data using this platform for different eye‐tracking data acquisition modes.MethodsAn eye‐tracker was integrated with a previously developed workstation designed for reader performance studies. The integrated system captured real‐time eye movement and workstation events at 1000 Hz sampling frequency. The eye‐tracker was operated either in head‐stabilized mode or in free‐movement mode. In head‐stabilized mode, the reader positioned their head on a manufacturer‐provided chinrest. In free‐movement mode, a biofeedback tool emitted an audio cue when the head position was outside the data collection range (general biofeedback) or outside a narrower range of positions near the calibration position (strict biofeedback). Four radiologists and one resident were invited to participate in three studies to determine eye‐tracking spatial accuracy under three constraint conditions: head‐stabilized mode (i.e., with use of a chin rest), free movement with general biofeedback, and free movement with strict biofeedback. Study 1 evaluated the impact of head stabilization versus general or strict biofeedback using a cross‐hair target prior to the integration of the eye‐tracker with the image viewing workstation. In Study 2, after integration of the eye‐tracker and reader workstation, readers were asked to fixate on targets that were randomly distributed within a volumetric digital phantom. In Study 3, readers used the integrated system to scroll through volumetric patient CT angiographic images while fixating on the centerline of designated blood vessels (from the left coronary artery to dorsalis pedis artery). Spatial accuracy was quantified as the offset between the center of the intended target and the detected fixation using units of image pixels and the degree of visual angle.ResultsThe three head position constraint conditions yielded comparable accuracy in the studies using digital phantoms. For Study 1 involving the digital crosshairs, the median ± the standard deviation of offset values among readers were 15.2 ± 7.0 image pixels with the chinrest, 14.2 ± 3.6 image pixels with strict biofeedback, and 19.1 ± 6.5 image pixels with general biofeedback. For Study 2 using the random dot phantom, the median ± standard deviation offset values were 16.7 ± 28.8 pixels with use of a chinrest, 16.5 ± 24.6 pixels using strict biofeedback, and 18.0 ± 22.4 pixels using general biofeedback, which translated to a visual angle of about 0.8° for all three conditions. We found no obvious association between eye‐tracking accuracy and target size or view time. In Study 3 viewing patient images, use of the chinrest and strict biofeedback demonstrated comparable accuracy, while the use of general biofeedback demonstrated a slightly worse accuracy. The median ± standard deviation of offset values were 14.8 ± 11.4 pixels with use of a chinrest, 21.0 ± 16.2 pixels using strict biofeedback, and 29.7 ± 20.9 image pixels using general biofeedback. These corresponded to visual angles ranging from 0.7° to 1.3°.ConclusionsAn integrated eye‐tracker system to assess reader eye movement and interactive viewing in relation to imaging targets demonstrated reasonable spatial accuracy for assessment of visual fixation. The head‐free movement condition with audio biofeedback performed similarly to head‐stabilized mode.