Back to Authors

Yalon, Mariana

https://orcid.org/0000-0001-7032-4068

Mayo Clinic

Mayo Clinic

Citations 8

Biomarker analysis of circulating tumor DNA in clinical stage III melanoma patients treated with neoadjuvant immunotherapy combined with targeted therapy
Yalon, Mariana , Bogan, Aaron, Block, Matthew S. , Hieken, Tina J. , Bogan, Aaron , Stoff, Ronen , Bogan, Aaron W , Hieken, Tina J , Routman, David M.

Therapeutic Advances in Medical Oncology | January 20, 2026 | Volume: 18 | Issue: No issue available | Pages: No page available

10.1177/17588359251412729 Get It

Background: Circulating tumor DNA (ctDNA) is predictive of recurrence in resected stage III melanoma, yet its role in the neoadjuvant setting for clinical stage III (cSIII) is unclear. Objective: Assess the association between ctDNA and outcomes following neoadjuvant immunotherapy (IO) + targeted therapy (TT) in cSIII melanoma. Design: Patients in the NeoACTIVATE study were treated with neoadjuvant IO + TT, underwent lymphadenectomy, and received adjuvant immunotherapy. Methods: Patients with ctDNA testing performed at baseline, pre- and post-operation were analyzed. Baseline positron emission tomography–computed tomography volumetrics and surgical, major pathological responses (MPR) were assessed. Results: Thirteen patients had serial ctDNA, 10 (77%) were detectable at baseline, and 9/10 (90%) had ctDNA clearance. Seven (54%) achieved MPR, all with undetectable preoperative ctDNA, yet 3/7 (43%) had disease recurrence. Conclusion: ctDNA and MPR are poor predictors of recurrence following neoadjuvant IO + TT for cSIII melanoma patients. Further studies are warranted to define the role of ctDNA in this setting.
Differentiating clinical characteristics of perianal inflammatory bowel disease from perianal hidradenitis suppurativa
Yamanaka‐Takaichi, Mika , Nadalian, Soheila, Loftus, Edward V. , Ehman, Eric C. , Grimaldo, Anna B. , Yalon, Mariana , Matchett, Caroline L. , Patel, Nisha , Isaq, Nasro , Raffals, Laura E., Wetter, David A. , Murphree, Dennis H. , Dozois, Eric J. , Yalon, Mariana , Patel, Nisha B, Isaq, Nasro A., Wetter, D A , Murphree, Dennis H , Tizhoosh, Hamid R , Alavi, A , Loftus, Edward V , Todd, Austin W. , Raffals, Laura E. , Cima, Robert R. , Goldfarb, Noah , Tizhoosh, Hamid R. , Alavi, Afsáneh

International Journal of Dermatology | September 22, 2024 | Volume: 64 | Issue: 3 | Pages: 520-530

10.1111/ijd.17498 Get It

Abstract Background Perianal draining tunnels in hidradenitis suppurativa (HS) and perianal fistulizing inflammatory bowel disease (IBD) present diagnostic and management dilemmas. Methods We conducted a retrospective chart review of patients with perianal disease evaluated at Mayo Clinic from January 1, 1998, through July 31, 2021. Patients' demographic and clinical data were extracted, and 28 clinical features were collected. After experimenting with several machine learning techniques, random forests were used to select the 15 most important clinical features to construct the diagnostic prediction model to distinguish perianal HS from fistulizing perianal IBD. Results A total of 263 patients were included (98 with HS, 100 with IBD, and 65 with both IBD and HS). Patients with HS had a higher mean body mass index, a higher smoking rate, and more commonly showed cutaneous manifestations of tunnels and comedones, while fistulas, abscesses, induration, anal tags, ulcers, and anal fissures were more common in patients with IBD. In addition to having lesions in the perianal area, patients with IBD often had lesions in the buttocks and perineum, while those with HS had additional lesions in the axillae and groin. Among the statistically significant features, the 15 most important were identified by random forest: fistula , tunnel , digestive symptom , knife‐cut ulcer , perineum , body mass index , age , axilla , abscess , tags , smoking , groin , genital cutaneous edema , erythema , and bilateral/unilateral . Conclusions The results of this study may help differentiate perianal lesions, especially perineal HS and fistulizing perineal IBD, and provide promise for a better therapeutic outcome.
Simultaneous high‐pitch multi‐energy CT pulmonary angiography using a dual‐source photon‐counting‐detector CT: A phantom experiment
Bruesewitz, Michael R. , Swicklik, Joseph R., Yalon, Mariana , Yu, Lifeng , Mihailovic, Jelena M , Rajiah, Prabhakar S., Mihailović, Jelena M. , Rajiah, Prabhakar , Fletcher, Joel G. , McCollough, Cynthia H. , Yu, Lifeng

Journal of Applied Clinical Medical Physics | August 29, 2024 | Volume: 25 | Issue: 11 | Pages: No page available

10.1002/acm2.14496 Get It

AbstractPurposeA dual‐source CT system can be operated in a high‐pitch helical mode to provide a temporal resolution of 66 ms, which reduces motion artifacts in CT pulmonary angiography (CTPA). It can also be operated in a multi‐energy (ME) mode to provide iodine maps, beneficial in the evaluation of pulmonary embolism (PE). No energy‐integrating detector (EID) CT can perform simultaneous ME and high‐pitch acquisition. This phantom study aimed to evaluate the ability of a photon‐counting‐detector (PCD) CT to perform simultaneous high‐pitch and ME imaging for CTPA.MethodsA motion phantom was used to mimic the respiratory motion. Two tubes filled with iodine with intravascular thrombus mimicked by injecting glue within the tubes were placed along with 5, 10, and 15 mg/mL iodine samples, on a motion phantom at 20 and 30 revolutions per minute. Separate high‐pitch and ME EID‐CT scans and a single high‐pitch ME PCD scan were acquired and virtual monoenergetic images and iodine maps reconstructed. Percent thrombus occlusion was measured and compared between static and moving images.ResultsWhen there was motion, EID‐CT ME suffered from significant motion artifacts. The measured iodine concentrations with PCD‐CT in high‐pitch ME were more stable when there was a motion, with a lower standard deviation than EID‐CT in ME mode. The estimated percent thrombus occlusion dropped significantly with applied motion on EID‐CT, while PCD‐CT high‐pitch ME mode showed good agreement between measurements on static or moving images.ConclusionPCD‐CT with combined ME and high‐pitch mode facilitates simultaneous accurate iodine quantification and assessment of intravascular occlusion.
Performance of CT With Adrenal-Washout Protocol in Heterogeneous Adrenal Nodules: A Multiinstitutional Study
Corwin, Michael T. , Caoili, Elaine M. , Elsayes, Khaled M. , Garratt, Joanie , Hackett, Caitlin E. , Mohd, Zahid, Sharbidre, Kedar , Yalon, Mariana , Navin, Patrick J. , Hudson, Emma, Mohd, Zahid, Shehata, Mostafa , Wang, Mindy X. , Wilson, Machelle , Remer, Erick M.

American Journal of Roentgenology | February 28, 2024 | Volume: 222 | Issue: 5 | Pages: No page available

10.2214/ajr.23.30769 Get It

Staging of breast cancer in the breast and regional lymph nodes using contrast-enhanced photon-counting detector CT: accuracy and potential impact on patient management
Yalon, Mariana , Sae-Kho, Tiffany, Khanna, Akriti , Chang, Shaojie , Andrist, Boleyn R., Weber, Nikkole M. , Hoodeshenas, Safa , Ferrero, Andrea , Glazebrook, Katrina N. , Baffour, Francis I , Sae-Kho, Tiffany M. , McCollough, Cynthia H. , Baffour, Francis

British Journal of Radiology | January 10, 2024 | Volume: 97 | Issue: 1153 | Pages: 93-97

10.1093/bjr/tqad042 Get It

Abstract Objectives To describe the feasibility and evaluate the performance of multiphasic photon-counting detector (PCD) CT for detecting breast cancer and nodal metastases with correlative dynamic breast MRI and digital mammography as the reference standard. Methods Adult females with biopsy-proven breast cancer undergoing staging breast MRI were prospectively recruited to undergo a multiphasic PCD-CT using a 3-phase protocol: a non-contrast ultra-high-resolution (UHR) scan and 2 intravenous contrast-enhanced scans with 50 and 180 s delay. Three breast radiologists compared CT characteristics of the index malignancy, regional lymphadenopathy, and extramammary findings to MRI. Results Thirteen patients underwent both an MRI and PCD-CT (mean age: 53 years, range: 36-75 years). Eleven of thirteen cases demonstrated suspicious mass or non-mass enhancement on PCD-CT when compared to MRI. All cases with metastatic lymphadenopathy (3/3 cases) demonstrated early avid enhancement similar to the index malignancy. All cases with multifocal or multicentric disease on MRI were also identified on PCD-CT (3/3 cases), including a 4 mm suspicious satellite lesion. Four of five patients with residual suspicious post-biopsy calcifications on mammograms were detected on the UHR PCD-CT scan. Owing to increased field-of-view at PCD-CT, a 5 mm thoracic vertebral metastasis was identified at PCD-CT and not with the breast MRI. Conclusions A 3-phase PCD-CT scan protocol shows initial promising results in characterizing breast cancer and regional lymphadenopathy similar to MRI and detects microcalcifications in 80% of cases. Advances in knowledge UHR and spectral capabilities of PCD-CT may allow for comprehensive characterization of breast cancer and may represent an alternative to breast MRI in select cases.
Infrapopliteal Segments on Lower Extremity CTA: Prospective Intraindividual Comparison of Energy-Integrating Detector CT and Photon-Counting Detector CT
Yalon, Mariana , Thorne, Jamison E. , Lee, Yong S. , Johnson, Matthew P. , Esquivel, Andrea , Rajiah, Prabhakar Shantha, Inoue, Akitoshi , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Rajiah, Prabhakar

American Journal of Roentgenology | December 20, 2023 | Volume: 222 | Issue: 3 | Pages: No page available

10.2214/ajr.23.29778 Get It

Imaging of Fontan-Associated Liver Disease
Brown, Mark J. F. , Kolbe, Amy B. , Hull, Nathan C. , Hilscher, Moira , Kamath, Patrick S. , Yalon, Mariana , Gu, Chris N., Amawi, Ali Dean Tahboub , Wells, Michael , Brown, Mark J., Venkatesh, Sudhakar K.

Journal of Computer Assisted Tomography | August 14, 2023 | Volume: 48 | Issue: 1 | Pages: 1-11

10.1097/rct.0000000000001533 Get It

Abstract The Fontan procedure is the definitive treatment for patients with single-ventricle physiology. Surgical advances have led to a growing number of patients surviving into adulthood. Fontan-associated liver disease (FALD) encompasses a spectrum of pathologic liver changes that occur secondary to altered physiology including congestion, fibrosis, and the development of liver masses. Assessment of FALD is difficult and relies on using imaging alongside of clinical, laboratory, and pathology information. Ultrasound, computed tomography, and magnetic resonance imaging are capable of demonstrating physiologic and hepatic parenchymal abnormalities commonly seen in FALD. Several novel imaging techniques including magnetic resonance elastography are under study for use as biomarkers for FALD progression. Imaging has a central role in detection and characterization of liver masses as benign or malignant. Benign FNH-like masses are commonly encountered; however, these can display atypical features and be mistaken for hepatocellular carcinoma (HCC). Fontan patients are at elevated risk for HCC, which is a feared complication and has a poor prognosis in this population. While imaging screening for HCC is widely advocated, no consensus has been reached regarding an optimal surveillance regimen.
Eosinophilic Disorders of the Gastrointestinal Tract and Associated Abdominal Viscera: Imaging Findings and Diagnosis
Yalon, Mariana , Amawi, Ali Dean Tahboub , Kelm, Zachary S. , Wells, Michael , Teo, Lynette , Heiken, Jay P. , Sheedy, Shannon P. , Torbenson, Michael , Fidler, Jeff L. , Venkatesh, Sudhakar K. , Tahboub Amawi, Ali D , Wells, Michael L , Teo, Lynette L S , Torbenson, Michael S , Venkatesh, Sudhakar K , Yalon, Mariana , Fidler, Jeff L.

RadioGraphics | June 24, 2022 | Volume: 42 | Issue: 4 | Pages: 1081-1102

10.1148/rg.220004 Get It