Citations 5

Improved Visualization of Middle Ear Prostheses using Photon-Counting Detector CT: A Cadaver Study
Sadeghian, Maryam, Benson, John C. , Lane, John I. , Treb, Kevin , Khandalavala, Karl R. , Babajanian, Eric E. , Bruesewitz, Michael R. , Swicklik, Joseph R., Ou, Fang‐Shu , McCollough, Cynthia H, Carlson, Matthew L, Leng, Shuai, Ou, Fang-Shu , Sadeghian, Maryam , Farnsworth, Paul J. , McCollough, Cynthia H. , Carlson, Matthew L. , Leng, Shuai

Radiology Advances | September 14, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/radadv/umag041 Get It

Abstract Background Evaluation of middle ear prostheses requires high-resolution imaging to assess position and structural integrity. Purpose To assess the diagnostic performance of photon-counting-detector (PCD)-CT for middle ear prosthesis imaging in cadaveric specimens. Materials and Methods Nine different middle ear prostheses were implanted in five fresh-frozen whole-head specimens, both in correct anatomic position and displaced to mimic malposition. Specimens were scanned on PCD-CT (NAEOTOM Alpha, Siemens) and energy-integrating-detector (EID)-CT (SOMATOM Force, Siemens), reconstructed at 0.2mm and 0.4mm, respectively. Eighteen cases (9 prostheses, 2 positions) per scanner were evaluated by two neuroradiologists (36 readings), blinded to scanner and position, who scored prosthesis position, reader confidence, and overall image quality. Agreement with the reference standard and between readers was compared. Results PCD-CT showed higher diagnostic confidence compared with EID-CT, while accuracy and inter-reader agreement did not demonstrate significant differences between scanners. Correct readings, PCD-CT versus EID-CT: lateral contact, 31/36 (86.1%; 95% CI: 58.3%-94.4%) vs. 29/36 (80.6%; 55.6%-91.7%), p = 0.500; medial contact, 30/36 (83.3%; 55.6%-94.4%) vs. 26/36 (72.2%; 50.0%-83.3%), p = 0.250. PCD-CT identified all cases of complete contact loss (score 3), while EID-CT missed one reading per contact. Inter-reader agreement may be higher with PCD-CT vs EID-CT (lateral: κw: 0.804 [0.578-0.941] vs. 0.571 [0.302-0.778], p = 0.250; medial: 0.684 [0.191-0.934] vs. 0.481 [0.024-0.835], p = 0.250). Reader confidence was significantly higher with PCD-CT; mean paired differences for Readers 1 and 2 were 9.4 (1.8-17.1; Holm-adjusted p = 0.019) and 23.1 points (13.4-32.7; p < 0.001) for lateral contact, and 16.4 (10.0-22.8; p < 0.001) and 17.8 points (6.8-28.8; p = 0.007) for medial contact. Readers preferred PCD-CT image quality in 16/18 (88.9%; 65.3%-98.6%) and 17/18 cases (94.4%; 72.7%-99.9%), respectively. Conclusion PCD-CT was associated with significantly higher reader confidence and preferred image quality, without significant differences in diagnostic accuracy or inter-reader agreement. These findings suggest PCD-CT is a promising modality for postoperative middle ear evaluations that warrants further investigations.
CT data harmonization via learned virtual monoenergetic imaging for cross‐kV scan translation and radiomics reproducibility
Chang, Shaojie , Swicklik, Joseph R., Zhou, Zhongxing, Kharat, Shravani, Wellinghoff, Jarod , Gong, Hao , Williamson, Eric E. , Foley, Thomas A. , McCollough, Cynthia H., Leng, Shuai, Gong, Hao , McCollough, Cynthia H. , Leng, Shuai

Medical Physics | March 26, 2026 | Volume: 53 | Issue: 4 | Pages: No page available

10.1002/mp.70403 Get It

Abstract Background Radiomics extracts quantitative imaging features from computed tomography (CT) data for clinical decision‐making. However, variations in acquisition parameters—particularly x‐ray tube voltage (kV)—introduce non‐biological variability in attenuation values, limiting the reproducibility of radiomic features across scanners, protocols, and institutions. Purpose To develop and evaluate a CT dAta harmoNiZAtion framework based on deep learNed vIrTual monoEnergetic imaging (TANZANITE), which leverages the keV flexibility of virtual monoenergetic images (VMIs) to enable cross‐kV scan translation and radiomics harmonization. Methods TANZANITE is a model hub consisting of multiple pre‐trained convolutional neural networks (CNNs), each designed to translate VMIs from 1 keV level to another. Phantom‐based calibration was first used to determine energy‐equivalent (Eff_E) keV levels corresponding to each tube potential (e.g., Eff_E(A) keV for source kV and Eff_E(B) keV for target kV). A CNN trained using 69 120 patches from seven patient cases to map VMIs from Eff_E(A) to Eff_E(B) was selected from the TANZANITE hub and applied directly to clinical CT images acquired at the source kV. This harmonized the images to match the attenuation characteristics of the target kV setting. Evaluation was conducted on independent dual‐energy CT datasets acquired at 100/Sn150 kV. Regions of interest (ROIs) were placed in the kidney, liver, and spine to assess CT number consistency and radiomic feature reproducibility. The concordance correlation coefficient (CCC) was calculated across 93 non‐shape radiomic features. Results After TANZANITE processing with 100 kV images, CT numbers in evaluated organs closely matched the Sn150 kV reference values in four testing patient cases. For example, mean kidney CT numbers changed from 320 HU (100 kV) to 156 HU (TANZANITE), approximating the Sn150 kV value of 160 HU. Similar changes were observed in the liver (157–105 HU vs. 104 HU reference) and spine (45–22 HU vs. 19 HU reference). Radiomic reproducibility improved substantially across organs: mean CCC increased from 0.590 to 0.995 in the liver, 0.300 to 0.970 in the kidney, and 0.630 to 0.968 in the spine. Post‐TANZANITE, over 98% of features exceeded the stability threshold (CCC ≥ 0.900) in all three representative organs. Conclusion TANZANITE provides a flexible, image‐domain harmonization framework by learning the keV‐to‐keV translation in the VMI domain and applying pre‐trained CNNs to clinical kV images. It improves CT number consistency and organ‐specific radiomic reproducibility without requiring raw projection data or scanner‐specific training. This approach supports consistent quantitative imaging across multiple‐kV acquisition protocols, enhancing radiomics reliability in clinical settings.
Simultaneous ultra-high resolution multi-energy cardiac imaging in a dual-source photon counting detector CT system
Shanblatt, Elisabeth R. , Swicklik, Joseph R., Allmendinger, Thomas , Schmidt, Bernhard , Flohr, Thomas , McCollough, Cynthia H. , Leng, Shuai , McCollough, Cynthia H , Leng, Shuai , Rajendran, Kishore

British Journal of Radiology | March 30, 2025 | Volume: 98 | Issue: 1175 | Pages: 1873-1879

10.1093/bjr/tqaf069 Get It

Abstract Objectives To assess quantitative and qualitative image characteristics in phantoms and patients using a simultaneous ultra-high resolution (UHR) and multi-energy (ME) dual-source cardiac scan mode in a photon counting detector (PCD) CT scanner. Methods UHR-ME cardiac scans were performed to determine the spatial resolution and multi-energy performance. UHR reconstructions were completed to measure transverse and axial spatial resolution in terms of modulation transfer function (MTF) and slice sensitivity profile (SSP). Virtual monoenergetic images (VMIs), virtual non-contrast (VNC) images, and iodine concentration images were created using moderately sharp reconstruction kernels to assess ME performance. With IRB approval, coronary CT angiograms were acquired in 19 patients using the UHR-ME mode, from which iodine contrast-to-noise ratio (CNR) was measured. Various ME post-processing tasks were performed to show the utility of the spectral capabilities. Results VMIs showed a mean CT number error of 6.0%, while iodine accuracy was 0.71 mg/cc (root-mean-square-error). Spatial resolution matched well with a standard UHR mode. Patient images showed a trend of higher CNR at lower keV, while higher keV images showed decreased calcium blooming. ME techniques to separate iodine and calcium were used successfully. Conclusions The combination of UHR-ME cardiac mode retains UHR image quality while providing flexibility for ME post-processing. Advances in knowledge Cardiac UHR-ME PCD-CT scanning offers simultaneous UHR and ME imaging without loss of spatial or temporal resolution or quantitative accuracy.
Simultaneous high‐pitch multi‐energy CT pulmonary angiography using a dual‐source photon‐counting‐detector CT: A phantom experiment
Bruesewitz, Michael R. , Swicklik, Joseph R., Yalon, Mariana , Yu, Lifeng , Mihailovic, Jelena M , Rajiah, Prabhakar S., Mihailović, Jelena M. , Rajiah, Prabhakar , Fletcher, Joel G. , McCollough, Cynthia H. , Yu, Lifeng

Journal of Applied Clinical Medical Physics | August 29, 2024 | Volume: 25 | Issue: 11 | Pages: No page available

10.1002/acm2.14496 Get It

AbstractPurposeA dual‐source CT system can be operated in a high‐pitch helical mode to provide a temporal resolution of 66 ms, which reduces motion artifacts in CT pulmonary angiography (CTPA). It can also be operated in a multi‐energy (ME) mode to provide iodine maps, beneficial in the evaluation of pulmonary embolism (PE). No energy‐integrating detector (EID) CT can perform simultaneous ME and high‐pitch acquisition. This phantom study aimed to evaluate the ability of a photon‐counting‐detector (PCD) CT to perform simultaneous high‐pitch and ME imaging for CTPA.MethodsA motion phantom was used to mimic the respiratory motion. Two tubes filled with iodine with intravascular thrombus mimicked by injecting glue within the tubes were placed along with 5, 10, and 15 mg/mL iodine samples, on a motion phantom at 20 and 30 revolutions per minute. Separate high‐pitch and ME EID‐CT scans and a single high‐pitch ME PCD scan were acquired and virtual monoenergetic images and iodine maps reconstructed. Percent thrombus occlusion was measured and compared between static and moving images.ResultsWhen there was motion, EID‐CT ME suffered from significant motion artifacts. The measured iodine concentrations with PCD‐CT in high‐pitch ME were more stable when there was a motion, with a lower standard deviation than EID‐CT in ME mode. The estimated percent thrombus occlusion dropped significantly with applied motion on EID‐CT, while PCD‐CT high‐pitch ME mode showed good agreement between measurements on static or moving images.ConclusionPCD‐CT with combined ME and high‐pitch mode facilitates simultaneous accurate iodine quantification and assessment of intravascular occlusion.
Task-based automatic keV selection: leveraging routine virtual monoenergetic imaging for dose reduction on clinical photon-counting detector CT *
Rajendran, Kishore , Bruesewitz, Michael R. , Swicklik, Joseph R., Ferrero, Andrea , Thorne, Jamison E. , Yu, Lifeng , Bruesewitz, Michael, Swicklik, Joseph, Thorne, Jamison, McCollough, Cynthia, Rajendran, Kishore , Yu, Lifeng , McCollough, Cynthia H. , Leng, Shuai

Physics in Medicine & Biology | April 22, 2024 | Volume: 69 | Issue: 11 | Pages: 115029

10.1088/1361-6560/ad41b3 Get It

Abstract Objective . Photon-counting detector (PCD) CT enables routine virtual-monoenergetic image (VMI) reconstruction. We evaluated the performance of an automatic VMI energy level (keV) selection tool on a clinical PCD-CT system in comparison to an automatic tube potential (kV) selection tool from an energy-integrating-detector (EID) CT system from the same manufacturer. Approach. Four torso-shaped phantoms (20–50 cm width) containing iodine (2, 5, and 10 mg cc −1 ) and calcium (100 mg cc −1 ) were scanned on PCD-CT and EID-CT. Dose optimization techniques, task-based VMI energy level and tube-potential selection on PCD-CT (CARE keV) and task-based tube potential selection on EID-CT (CARE kV), were enabled. CT numbers, image noise, and dose-normalized contrast-to-noise ratio (CNR d ) were compared. Main results . PCD-CT produced task-specific VMIs at 70, 65, 60, and 55 keV for non-contrast, bone, soft tissue with contrast, and vascular settings, respectively. A 120 kV tube potential was automatically selected on PCD-CT for all scans. In comparison, EID-CT used x-ray tube potentials from 80 to 150 kV based on imaging task and phantom size. PCD-CT achieved consistent dose reduction at 9%, 21% and 39% for bone, soft tissue with contrast, and vascular tasks relative to the non-contrast task, independent of phantom size. On EID-CT, dose reduction factor for contrast tasks relative to the non-contrast task ranged from a 65% decrease (vascular task, 70 kV, 20 cm phantom) to a 21% increase (soft tissue with contrast task, 150 kV, 50 cm phantom) due to size-specific tube potential adaptation. PCD-CT CNR d was equivalent to or higher than those of EID-CT for all tasks and phantom sizes, except for the vascular task with 20 cm phantom, where 70 kV EID-CT CNR d outperformed 55 keV PCD-CT images. Significance . PCD-CT produced more consistent CT numbers compared to EID-CT due to standardized VMI output, which greatly benefits standardization efforts and facilitates radiation dose reduction.