Gong, Hao

0000-0002-1123-7172

Mayo Clinic

Department of Radiology, Mayo Clinic, Rochester, MN, United States of America.

Citations 6

Model-based motion simulation framework for deep learning-assisted motion correction in dynamic wrist CT
Zhao, Kristin D. , Treb, Kevin , Gu, Chunming , Davis, Aeden K , Huang, Shengbing, Treb, Kevin , Trentadue, Taylor P , Sadeghian, Maryam , Baffour, Francis , Trentadue, Taylor P , Leng, Shuai , Gong, Hao , Gu, Chunming , Thoreson, Andrew R. , Lachman, Nirusha , Baffour, Francis, Trentadue, Taylor P. , Kakar, Sanjeev , McCollough, Cynthia H, Leng, Shuai , Gong, Hao

Physics in Medicine & Biology | September 11, 2026 | Volume: 71 | Issue: 18 | Pages: 185014

10.1088/1361-6560/aea684 Get It

Abstract Objective. Four-dimensional CT (4DCT) enables visualization of dynamic wrist joint pathology but may be compromised by motion artifacts. Deep learning (DL)-assisted motion correction has the potential to enhance wrist 4DCT quality, but model development is hindered by scarce training data. To address this, we developed a model-based motion simulation framework that generated realistic 4DCT data with paired static ground truth images to demonstrate wrist motion correction using a physics-informed DL model trained with simulated data. Approach. Wrist motion was simulated by synchronizing rotational and translational movements of carpal bones and connective tissues. Elastic deformation guided by analytically-derived motion vector fields was applied to static wrist scans at neutral positions to create artifact-free images at multiple angular positions. Virtual motion-corrupted 4DCT images were produced via forward projection and reconstruction with synchronized gantry and wrist motion. Experimental data from 4DCT cadaver scans were collected to validate simulation quality. Low-intensity region score (LIRS), positivity, and entropy were used to assess simulated motion artifacts. A physics-informed motion correction network was adapted exclusively using simulated training data and subsequently deployed on simulated, real cadaveric, and in vivo 4DCT scans. LIRS and structural similarity index (SSIM) were used to evaluate motion correction quality. Wilcoxon signed-rank tests were conducted ( α = 0.05). Results. The simulation method created realistic motion artifacts compared to real scan reference ( p > 0.05). Motion artifacts were effectively mitigated across testing cases demonstrating generalizability. In simulated scans, LIRS improved from 0.55 ± 0.12–0.75 ± 0.04 and SSIM from 0.87 ± 0.08–0.95 ± 0.03 at bone regions (each p < 0.01). In experimental cadaveric scans, LIRS improved from 0.05 ± 0.01–0.31 ± 0.17 in marker regions and from 0.58 ± 0.19–0.77 ± 0.14 in bone regions (each p < 0.01). Significance. Our simulation method facilitates training DL-assisted motion correction algorithms by providing high-quality training data, effectively supporting 4DCT image quality enhancement.
CT data harmonization via learned virtual monoenergetic imaging for cross‐kV scan translation and radiomics reproducibility
Chang, Shaojie , Swicklik, Joseph R., Zhou, Zhongxing, Kharat, Shravani, Wellinghoff, Jarod , Gong, Hao , Williamson, Eric E. , Foley, Thomas A. , McCollough, Cynthia H., Leng, Shuai, Gong, Hao , McCollough, Cynthia H. , Leng, Shuai

Medical Physics | March 26, 2026 | Volume: 53 | Issue: 4 | Pages: No page available

10.1002/mp.70403 Get It

Abstract Background Radiomics extracts quantitative imaging features from computed tomography (CT) data for clinical decision‐making. However, variations in acquisition parameters—particularly x‐ray tube voltage (kV)—introduce non‐biological variability in attenuation values, limiting the reproducibility of radiomic features across scanners, protocols, and institutions. Purpose To develop and evaluate a CT dAta harmoNiZAtion framework based on deep learNed vIrTual monoEnergetic imaging (TANZANITE), which leverages the keV flexibility of virtual monoenergetic images (VMIs) to enable cross‐kV scan translation and radiomics harmonization. Methods TANZANITE is a model hub consisting of multiple pre‐trained convolutional neural networks (CNNs), each designed to translate VMIs from 1 keV level to another. Phantom‐based calibration was first used to determine energy‐equivalent (Eff_E) keV levels corresponding to each tube potential (e.g., Eff_E(A) keV for source kV and Eff_E(B) keV for target kV). A CNN trained using 69 120 patches from seven patient cases to map VMIs from Eff_E(A) to Eff_E(B) was selected from the TANZANITE hub and applied directly to clinical CT images acquired at the source kV. This harmonized the images to match the attenuation characteristics of the target kV setting. Evaluation was conducted on independent dual‐energy CT datasets acquired at 100/Sn150 kV. Regions of interest (ROIs) were placed in the kidney, liver, and spine to assess CT number consistency and radiomic feature reproducibility. The concordance correlation coefficient (CCC) was calculated across 93 non‐shape radiomic features. Results After TANZANITE processing with 100 kV images, CT numbers in evaluated organs closely matched the Sn150 kV reference values in four testing patient cases. For example, mean kidney CT numbers changed from 320 HU (100 kV) to 156 HU (TANZANITE), approximating the Sn150 kV value of 160 HU. Similar changes were observed in the liver (157–105 HU vs. 104 HU reference) and spine (45–22 HU vs. 19 HU reference). Radiomic reproducibility improved substantially across organs: mean CCC increased from 0.590 to 0.995 in the liver, 0.300 to 0.970 in the kidney, and 0.630 to 0.968 in the spine. Post‐TANZANITE, over 98% of features exceeded the stability threshold (CCC ≥ 0.900) in all three representative organs. Conclusion TANZANITE provides a flexible, image‐domain harmonization framework by learning the keV‐to‐keV translation in the VMI domain and applying pre‐trained CNNs to clinical kV images. It improves CT number consistency and organ‐specific radiomic reproducibility without requiring raw projection data or scanner‐specific training. This approach supports consistent quantitative imaging across multiple‐kV acquisition protocols, enhancing radiomics reliability in clinical settings.
Deep Learning–based Monoenergetic Imaging for Calcified Coronary Stenosis Assessment at Energy-integrating Detector CT
Chang, Shaojie , Koons, Emily K. , Gong, Hao , Thorne, Jamison E. , Williamson, Eric E. , Foley, Thomas A. , McCollough, Cynthia H., Leng, Shuai, McCollough, Cynthia H. , Leng, Shuai , McCollough, Cynthia H , Leng, Shuai , Williamson, Eric , Thorne, Jamison E , Gong, Hao

Radiology: Cardiothoracic Imaging | March 19, 2026 | Volume: 8 | Issue: 2 | Pages: No page available

10.1148/ryct.250230 Get It

A deep learning–based neural network enabled virtual monoenergetic imaging at energy-integrating detector CT, reduced blooming artifacts, and improved stenosis assessment in heavily calcified coronary plaques, with performance comparable to ultrahigh-resolution photon-counting detector CT.
Motion artifact correction in cardiac CT using cross-phase temporospatial information and synergistic attention gate and spatial transformer sub-networks
Gong, Hao , Ahmed, Zaki, Chang, Shaojie , Koons, Emily K. , Thorne, Jamison E. , Foley, Thomas A. , Gong, Hao , Rajiah, Prabhakar , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Physics in Medicine & Biology | January 5, 2024 | Volume: 69 | Issue: 3 | Pages: 035023

10.1088/1361-6560/ad1b6a Get It

Abstract Objectives. To improve quality of coronary CT angiography (CCTA) images using a generalizable motion-correction algorithm. Approach . A neural network with attention gate and spatial transformer (ATOM) was developed to correct coronary motion. Phantom and patient CCTA images (39 males, 32 females, age range 19–92, scan date 02/2020 to 10/2021) retrospectively collected from dual-source CT were used to create training, development, and testing sets corresponding to 140- and 75 ms temporal resolution, with 75 ms images as labels. To test generalizability, ATOM was deployed for locally adaptive motion-correction in both 140- and 75 ms patient images. Objective metrics were used to assess motion-corrupted and corrected phantom and patient images, including structural-similarity-index (SSIM), dice-similarity-coefficient (DSC), peak-signal-noise-ratio (PSNR), and normalized root-mean-square-error (NRMSE). In objective quality assessment, ATOM was compared with several baseline networks, including U-net, U-net plus attention gate, U-net plus spatial transformer, VDSR, and ResNet. Two cardiac radiologists independently interpreted motion-corrupted and -corrected images at 75 and 140 ms in a blinded fashion and ranked diagnostic image quality (worst to best: 1–4, no ties). Main results . ATOM improved quality metrics ( p < 0.05) before/after correction: in phantom, SSIM 0.87/0.95, DSC 0.85/0.93, PSNR 19.4/22.5, NRMSE 0.38/0.27; in patient images, SSIM 0.82/0.88, DSC 0.88/0.90, PSNR 30.0/32.0, NRMSE 0.16/0.12. ATOM provided more consistent improvement of objective image quality, compared to the presented baseline networks. The motion-corrected images received better ranks than un-corrected at the same temporal resolution ( p < 0.05): 140 ms images 1.65/2.25, and 75 ms images 3.1/3.2. The motion-corrected 75 ms images received the best rank in 65% of testing cases. A fair-to-good inter-reader agreement was observed (Kappa score 0.58). Significance . ATOM reduces motion artifacts, improving visualization of coronary arteries. This algorithm can be used to virtually improve temporal resolution in both single- and dual-source CT.
Deep learning‐based virtual noncalcium imaging in multiple myeloma using dual‐energy CT
Gong, Hao , Glazebrook, Katrina N. , Rhodes, Nicholas G. , Thorne, Jamison E. , Kumar, Shaji , Tiegs-Heiden, Christin A, Gong, Hao , Baffour, Francis , Tiegs‐Heiden, Christin A. , Cook, Joselle , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Medical Physics | August 19, 2022 | Volume: 49 | Issue: 10 | Pages: 6346-6358

10.1002/mp.15934 Get It

AbstractBackgroundDual‐energy CT with virtual noncalcium (VNCa) images allows the evaluation of focal intramedullary bone marrow involvement in patients with multiple myeloma. However, current commercial VNCa techniques suffer from excessive image noise and artifacts due to material decomposition used in synthesizing VNCa images.ObjectivesIn this work, we aim to improve VNCa image quality for the assessment of focal multiple myeloma, using an Artificial intelligence based Generalizable Algorithm for mulTi‐Energy CT (AGATE) method.Materials and methodsAGATE method used a custom dual‐task convolutional neural network (CNN) that concurrently carries out material classification and quantification. The material classification task provided an auxiliary regularization to the material quantification task. CNN parameters were optimized using custom loss functions that involved cross‐entropy, physics‐informed constraints, structural redundancy in spectral and material images, and texture information in spectral images. For training data, CT phantoms (diameters 30 to 45 cm) with tissue‐mimicking inserts were scanned on a third generation dual‐source CT system. Scans were performed at routine dose and half of the routine dose. Small image patches (i.e., 40 × 40 pixels) of tissue‐mimicking inserts with known basis material densities were extracted for training samples. Numerically simulated insert materials with various shapes increased diversity of training samples. Generalizability of AGATE was evaluated using CT images from phantoms and patients. In phantoms, material decomposition accuracy was estimated using mean‐absolute‐percent‐error (MAPE), using physical inserts that were not used during the training. Noise power spectrum (NPS) and modulation transfer function (MTF) were compared across phantom sizes and radiation dose levels. Five patients with multiple myeloma underwent dual‐energy CT, with VNCa images generated using a commercial method and AGATE. Two fellowship‐trained musculoskeletal radiologists reviewed the VNCa images (commercial and AGATE) side‐by‐side using a dual‐monitor display, blinded to VNCa type, rating the image quality for focal multiple myeloma lesion visualization using a 5‐level Likert comparison scale (−2 = worse visualization and diagnostic confidence, −1 = worse visualization but equivalent diagnostic confidence, 0 = equivalent visualization and diagnostic confidence, 1 = improved visualization but equivalent diagnostic confidence, 2 = improved visualization and diagnostic confidence). A post hoc assignment of comparison ratings was performed to rank AGATE images in comparison to commercial ones.ResultsAGATE demonstrated consistent material quantification accuracy across phantom sizes and radiation dose levels, with MAPE ranging from 0.7% to 4.4% across all testing materials. Compared to commercial VNCa images, the AGATE‐synthesized VNCa images yielded considerably lower image noise (50–77% noise reduction) without compromising noise texture or spatial resolution across different phantom sizes and two radiation doses. AGATE VNCa images had markedly reduced area under NPS curves and maintained NPS peak frequency (0.7 lp/cm to 1.0 lp/cm), with similar MTF curves (50% MTF at 3.0 lp/cm). In patients, AGATE demonstrated reduced image noise and artifacts with improved delineation of focal multiple myeloma lesions (all readers comparison scores indicating improved overall diagnostic image quality [scores 1 or 2]).ConclusionsAGATE demonstrated reduced noise and artifacts in VNCa images and ability to improve visualization of bone marrow lesions for assessing multiple myeloma.
Deep learning enabled ultra‐fast‐pitch acquisition in clinical X‐ray computed tomography
Gong, Hao , Ren, Liqiang , Hsieh, Scott S. , Yu, Lifeng , Gong, Hao , McCollough, Cynthia H. , Yu, Lifeng

Medical Physics | August 20, 2021 | Volume: 48 | Issue: 10 | Pages: 5712-5726

10.1002/mp.15176 Get It

AbstractObjectiveIn X‐raycomputed tomography (CT), many important clinical applications may benefit from a fast acquisition speed. The helical scan is the most widely used acquisition mode in clinical CT, where a fast helical pitch can improve the acquisition speed. However, on a typical single‐source helical CT (SSCT) system, the helical pitch p typically cannot exceed 1.5; otherwise, reconstruction artifacts will result from data insufficiency. The purpose of this work is to develop a deep convolutional neural network (CNN) to correct for artifacts caused by an ultra‐fast pitch, which can enable faster acquisition speed than what is currently achievable.MethodsA customized CNN (denoted as ultra‐fast‐pitch network (UFP‐net)) was developed to restore the underlying anatomical structure from the artifact‐corrupted post‐reconstruction data acquired from SSCT with ultra‐fast pitch (i.e., p ≥ 2). UFP‐net employed residual learning to capture the features of image artifacts. UFP‐net further deployed in‐house‐customized functional blocks with spatial‐domain local operators and frequency‐domain non‐local operators, to explore multi‐scale feature representation. Images of contrast‐enhanced patient exams (n = 83) with routine pitch setting (i.e., p < 1) were retrospectively collected, which were used as training and testing datasets. This patient cohort involved CT exams over different scan ranges of anatomy (chest, abdomen, and pelvis) and CT systems (Siemens Definition, Definition Flash, Definition AS+, Siemens Healthcare, Inc.), and the corresponding base CT scanning protocols used consistent settings of major scan parameters (e.g., collimation and pitch). Forward projection of the original images was calculated to synthesize helical CT scans with one regular pitch setting (p = 1) and two ultra‐fast‐pitch setting (p = 2 and 3). All patient images were reconstructed using the standard filtered‐back‐projection (FBP) algorithm. A customized multi‐stage training scheme was developed to incrementally optimize the parameters of UFP‐net, using ultra‐fast‐pitch images as network inputs and regular pitch images as labels. Visual inspection was conducted to evaluate image quality. Structural similarity index (SSIM) and relative root‐mean‐square error (rRMSE) were used as quantitative quality metrics.ResultsThe UFP‐net dramatically improved image quality over standard FBP at both ultra‐fast‐pitch settings. At p = 2, UFP‐net yielded higher mean SSIM (> 0.98) with lower mean rRMSE (< 2.9%), compared to FBP (mean SSIM < 0.93; mean rRMSE > 9.1%). Quantitative metrics at p = 3: UFP‐net—mean SSIM [0.86, 0.94] and mean rRMSE [5.0%, 8.2%]; FBP—mean SSIM [0.36, 0.61] and mean rRMSE [36.0%, 58.6%].ConclusionThe proposed UFP‐net has the potential to enable ultra‐fast data acquisition in clinical CT without sacrificing image quality. This method has demonstrated reasonable generalizability over different body parts when the corresponding CT exams involved consistent base scan parameters.