Abstract Objective. Four-dimensional CT (4DCT) enables visualization of dynamic wrist joint pathology but may be compromised by motion artifacts. Deep learning (DL)-assisted motion correction has the potential to enhance wrist 4DCT quality, but model development is hindered by scarce training data. To address this, we developed a model-based motion simulation framework that generated realistic 4DCT data with paired static ground truth images to demonstrate wrist motion correction using a physics-informed DL model trained with simulated data. Approach. Wrist motion was simulated by synchronizing rotational and translational movements of carpal bones and connective tissues. Elastic deformation guided by analytically-derived motion vector fields was applied to static wrist scans at neutral positions to create artifact-free images at multiple angular positions. Virtual motion-corrupted 4DCT images were produced via forward projection and reconstruction with synchronized gantry and wrist motion. Experimental data from 4DCT cadaver scans were collected to validate simulation quality. Low-intensity region score (LIRS), positivity, and entropy were used to assess simulated motion artifacts. A physics-informed motion correction network was adapted exclusively using simulated training data and subsequently deployed on simulated, real cadaveric, and in vivo 4DCT scans. LIRS and structural similarity index (SSIM) were used to evaluate motion correction quality. Wilcoxon signed-rank tests were conducted ( α = 0.05). Results. The simulation method created realistic motion artifacts compared to real scan reference ( p > 0.05). Motion artifacts were effectively mitigated across testing cases demonstrating generalizability. In simulated scans, LIRS improved from 0.55 ± 0.12–0.75 ± 0.04 and SSIM from 0.87 ± 0.08–0.95 ± 0.03 at bone regions (each p < 0.01). In experimental cadaveric scans, LIRS improved from 0.05 ± 0.01–0.31 ± 0.17 in marker regions and from 0.58 ± 0.19–0.77 ± 0.14 in bone regions (each p < 0.01). Significance. Our simulation method facilitates training DL-assisted motion correction algorithms by providing high-quality training data, effectively supporting 4DCT image quality enhancement.
Rapid personalized computational modeling of the wrist
Abstract Background/Purpose Diagnosing wrist ligament injuries is challenging; early detection and treatment are important to prevent osteoarthritis progression. Interosseous proximity maps, a proxy measure for joint space, can be generated from volumetric imaging data and may provide important information about wrist health. Artificial intelligence (AI) could enhance accuracy of noninvasive diagnosis based on imaging-derived metrics. This work demonstrates feasibility of AI training using synthetic proximity map data generated from finite element models (FEMs). Methods Personalized wrist FEMs for two asymptomatic participants were created from four-dimensional computed tomography-derived anatomic and kinematic data. Monte Carlo sampling varied 22 ligament material properties and simulated 7,500 unique injury scenarios generating 9,000,000 labeled red, green, and blue (RGB) images of interosseous proximity vector fields from FEM-derived motions. Images were associated with 17 descriptive metrics, including gross wrist angles and bone surface pairs, and used to develop mixed-input convolutional neural networks (CNNs). Model performance was evaluated for identifying specific ligament injuries. Results Average area under receiver operating characteristic curve (AUROC) for CNNs was 0.757 across all injury types and kinematics. In a subset with clinically-relevant functional angles, the average AUROC was 0.824. Best-performing individual ligament AUROCs ranged from 0.807 to 0.999. Sensitivities and specificities exceeded 0.99 for some ligament injury simulations under specific wrist angles and bone surface pairs. Conclusion This study demonstrates the feasibility of using synthetic data from FEMs to train AI models for classifying wrist ligament injuries. Proximity-based RGB images may be a relevant biomarker of ligamentous injury.
Finite Element Modeling of the Scaphoid Shift Maneuver: Implications for Scapholunate Ligament injuries
Abstract Background Computational modeling is a tool being deployed for orthopaedic solutions but its use in the hand and wrist remains limited. This work used a model to simulate a clinically relevant provocative scaphoid shift maneuver (SSM) with different levels of scapholunate interosseous ligament (SLIL) injuries to observe the effect on different metrics. Methods A personalized model simulated the full SSM motion cycle from ulnar deviation with extension to radial deviation with flexion informed by the participant’s motion obtained from dynamic computed tomography. Models repeated the SSM under different levels of SLIL injury and reported changes in joint kinematics, contact mechanics, and ligament forces. Results The fully injured model increased scaphoid dorsal translation, flexion, and radial deviation compared to the intact condition and caused a subluxation of the scaphoid. Radioscaphoid contact areas were approximately 200% greater in the fully injured model compared with all others and the fully injured model was the only condition where contact force decreased across the motion cycle. Ligament forces in the intact condition were on average 33.0 N and 54.2 N for the volar and dorsal SLIL, respectively. Lastly, the long radiolunate, an extrinsic stabilizer, had forces that increased following SLIL injury. Conclusions Computational models can successfully recreate clinically observed behaviors of an SSM, including scaphoid subluxation, while providing new insights via quantification of contact mechanics and ligament forces. Contact mechanics metrics may be important for understanding the long-term progression of untreated SLIL injuries to osteoarthritis. Additionally, ligament force metrics may explain the progression of SLIL injuries from volar SLIL to dorsal SLIL and highlight the importance of repairing extrinsic stabilizers of the joint, due to increased force sharing following SLIL injury. This work provides a pathway to future studies investigating the effects of SLIL injury and repair, both acutely and chronically.
Percutaneous Spinal Cord Stimulator Enables Novel Clonus Biomarker and Management in Persons With Spinal Cord Injury and Multiple Sclerosis: An Exploratory Study
Background: Spasticity is common in spinal cord injury (SCI) and multiple sclerosis (MS), and it can manifest as repeated, rhythmic muscle contractions called clonus. The spontaneous nature of clonus can disrupt independent performance of activities of daily living and negatively impact overall health and quality of life. Objectives: To quantify biomarkers of clonus and explore management of clonus in individuals with SCI or progressive MS using epidural spinal cord stimulation (ES) or dorsal root stimulation (DRS). Methods: Four male participants were included in this case series study: 3 with SCI and 1 with MS. All participants underwent temporary percutaneous ES lead placement over the dorsolateral thoracolumbar region of the spinal cord. Participants with SCI were also implanted with DRS leads at the L4 dorsal root. Clonus was elicited mechanically at the ankle while recording electromyography of the soleus muscle synchronized to direct spinal cord field potential recordings from ES and DRS percutaneous leads. Results: Clonus was evident as a prominent band (5-8 Hz) in recordings from ES leads, DRS leads, soleus muscle, and accelerometry. In 4 participants, percutaneous spinal stimulation reduced median clonus duration and cycle count. Clonus was immediately suppressed upon activation of spinal cord stimulation, and the suppression persisted even when clonus was reinitiated after turning off the stimulation. Conclusion: The use of objective biomarkers, including spinal cord potentials, to quantify clonus in real time combined with the immediate and reversible effects of stimulation highlight the potential of neuromodulation as a therapeutic tool for managing clonus. These data demonstrate preliminary efficacy of ES and DRS for clonus monitoring and treatment in 4 participants.
ISNCSCI Exam Changes Following Spinal Cord Stimulation
Objectives: To describe changes in the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI) exam in sublesional motor and sensory domains following short-term epidural electrical stimulation of lumbosacral spinal segments in individuals with spinal cord injury (SCI). Methods: Twenty individuals with SCI underwent implantation of percutaneous epidural spinal cord stimulation followed by stimulation parameter optimization and 10-12 sessions of stimulation-enabled motor training. Pre-/postintervention ISNCSCI exams were compared to determine changes in motor/sensory scores for regions within 3 levels of the neurological level of injury (NLI) and caudal to this, with subanalyses per motor/sensory complete versus incomplete baseline status. Results: Individuals with motor complete SCI gained 6% ± 3% of available motor points within 3 levels of NLI and 1% ± 0% of motor points caudal to this ( P = .08). Motor incomplete individuals gained 9% ± 22% of available motor points within 3 levels of NLI and lost 4% ± 7% of motor points caudal to this ( P = .63). Following stimulation, changes in motor scores with potential high functional impact occurred in 3 individuals (5 total muscle groups with conversion from baseline <3/5 strength to ≥3/5 at completion). Individuals with sensory complete SCI had fewer sensory gains within 3 levels of NLI (6%) compared to those with sensory incomplete SCI (30%, P = .02). Discussion: Spinal cord stimulation after SCI rapidly induces changes in both motor and sensory domains that are retained after stimulation is removed. These changes primarily occur within 3 levels of the NLI and occur to a greater degree in those with incomplete SCI.
Four-Dimensional Computed Tomography-Derived Radiolunate Arthrokinematics With a Case Study in Four-Corner Arthrodesis
Background: The radiolunate joint is conventionally thought to be spared from radiocarpal osteoarthritis, but proximal lunate degenerative changes have been noted. An investigation of radiolunate arthrokinematics in ostensibly healthy wrists may improve understanding of posttraumatic and postoperative outcomes. We hypothesize that four-dimensional computed tomography (4DCT)-derived radiolunate arthrokinematics during motion will differ between wrists with type 1 and type 2 lunates. The clinical-translational relevance of this analysis is highlighted using a 4DCT case study of scaphoid excision with 4-corner arthrodesis (SEFCA). Methods: Four-dimensional computed tomography data were collected during flexion-extension and radioulnar deviation in 19 healthy wrists (mean [SD] age: 43.6 [11.7] years, 21.1% female) and 1 wrist 3 years after SEFCA (male, 52 years). Carpal osteokinematics and joint arthrokinematics were calculated to derive median radiolunate interosseous proximities at each 4DCT-captured timepoint. Results: Median radiolunate interosseous proximities during motion are well approximated by second-order regressions in uninjured wrists. In the arthrodesed wrist, closest proximities occurred at the extremes of motion except maximum radial deviation. Conclusions: This study quantifies a normative range of median radiolunate interosseous proximities during wrist motion. The normative 4DCT datasets provide a reference range for evaluating postoperative arthrokinematics, suggesting the clinical-translational potential of dynamic imaging. The case study highlights applications for patient-level postoperative evaluation, which can be expanded to other pathologies, surgeries, or conditions in the future.
Percutaneous epidural spinal cord stimulation immediately reduces clonus in an individual with multiple sclerosis
Clonus is a disabling symptom of upper motor neuron dysfunction in patients with multiple sclerosis (MS). We report immediate termination of mechanically evoked clonus by epidural lumbosacral spinal cord stimulation (ES) in a 58-year-old man with secondary progressive MS. This observation was captured during training using video and skin surface electromyography of soleus muscle activity. ES immediately reduced mechanically evoked clonus duration and cycle count compared to trials without stimulation, as determined by a Kruskal–Wallis test ( p < 0.05, n = 2–3 trials), and reverted to baseline status when stimulation was off.
Impact of Reach Height on Estimated Rotator Cuff Compression Risk in Manual Wheelchair Users With Spinal Cord Injury
Reaching is a common daily activity requiring a range of humeral elevation that contributes to rotator cuff compression. The purpose of this study was to estimate supraspinatus and infraspinatus tendon compression risk relative to the acromion and coracoacromial ligament during reaching by manual wheelchair users with spinal cord injury. A cross-sectional design was used to evaluate 8 participants (7 males, median [range] age 36 y [23–61]). Electromagnetic motion capture recorded shoulder kinematics while participants reached for a can at 2 heights: low (0.91 m) and high (1.37 m). Using 1 set of computed tomographic-based bone models and individual glenohumeral kinematics, compression risk was evaluated as the percentage of the reach activity and number of seconds that tendon insertions were less than 5 mm from scapular landmarks. Reach conditions were compared using a Wilcoxon signed-rank test (α = .05). Although not statistically significant, the supraspinatus and infraspinatus relative to the acromion had approximately 40% of the activity duration or 0.8 seconds more time under 5 mm in low versus high reach, indicating increased risk of compression. Compression risk estimates were consistent with prior publications on planar arm movements. Estimating the risk of tendon compression using absolute time may help with understanding cumulative exposure during day-to-day activity.
Prevalence of autonomic dysreflexia during spinal cord stimulation after spinal cord injury
Spinal cord stimulation for motor recovery after spinal cord injury is a popular research intervention, though off-target effects are a concern. Using continual blood pressure and heart rate recordings during passive spinal cord stimulation parameter testing, we identified frequent episodes of autonomic dysreflexia that were rarely associated with symptoms. This presents a previously unrecognized risk of spinal cord stimulation and appropriate vigilance in targeted monitoring is urged to maintain participant safety.