Technical performance of dual‐contrast‐agent K‐edge imaging with four energy thresholds on a commercial photon counting detector CT
Treb, Kevin , Marsh, Jeffrey F., Shanblatt, Elisabeth R. , Nowak, Tristan , Dunning, Chelsea A. S. , Fung, George S. K. , Schmidt, Bernhard , McCollough, C, Leng, Shuai, Treb, Kevin J, Treb, Kevin , Leng, Shuai

Medical Physics | October 8, 2025 | Volume: 52 | Issue: 10 | Pages: No page available

10.1002/mp.70063 Get It

Abstract Background Photon counting detector CT (PCD‐CT) has the potential to sort detected x‐ray photons into more than two energy bins to perform multi‐material decomposition using K‐edge materials without additional mathematical constraints/assumptions. The availability of multiple energy thresholds in PCD‐CT opens the possibility for unique clinical applications such as simultaneous multi‐contrast‐agent imaging. Purpose To evaluate the technical performance of a PCD‐CT system with four energy thresholds for conducting multi‐material decomposition of iodine, gadolinium, and water after a comprehensive system calibration procedure. Methods Experiments were performed on a commercial PCD‐CT scanner (NAEOTOM Alpha, Siemens Healthineers) using a research mode with four energy thresholds. Material calibration was performed by scanning contrast materials with known concentration placed in various sizes of cylindrical water‐equivalent phantoms at various tube currents and positions. From these data, per‐voxel contrast models were derived for each material by multiple linear regressions up to second order, where the predictor variables were combinations of tube current, phantom diameter, and distance to isocenter. After calibration, small (20 cm diameter) and large (30 cm × 40 cm) uniform multi‐energy CT phantoms and an anthropomorphic thorax phantom (31 cm × 39 cm), each containing bone, soft tissue, and several quantitative inserts of iodine (0.2–5.0 mg/ml), gadolinium (0.3–5.0 mg/ml), and a mixture of both (5.0 mg/ml each) were scanned using the four‐energy threshold mode at 140 kV with energy thresholds set at 20, 52, 75, and 82 keV. Images for each energy threshold were reconstructed with a filtered back‐projection algorithm and a quantitative kernel (Qr44). Subsequent image‐based material decomposition was performed on individual voxels of the energy threshold images using the models derived from the calibration process to generate water, iodine, and gadolinium basis images. Quantitative material concentrations and image noise magnitudes, and noise power spectra (NPS) were measured. Results Iodine and gadolinium concentrations above 1.25 mg/ml were visible in the material basis images in all phantoms. Averaged quantitative accuracy for iodine and gadolinium in the small, large, and thorax phantoms were 0.39 ± 0.30 mg/ml, 0.96 ± 0.53 mg/ml, and 0.53 ± 0.35 mg/ml, respectively. In the water basis images, accuracy was within 24 HU in all phantoms. Noise magnitudes in iodine and gadolinium basis images were 2.91 and 3.52 times that of the lowest energy threshold image for the small phantom, and were 6.92 and 7.17 times that of the lowest threshold image for the large phantom. Noise texture did not change between the energy threshold and material basis images for either size phantom as measured by the NPS. Conclusions After a comprehensive system calibration, a commercial PCD‐CT with four energy thresholds performed multiple material decomposition of iodine, gadolinium, and water for concentrations above 1.25 mg/ml in human‐sized phantoms. Noise amplification and quantitative accuracy from the decomposition greatly depended on object size.
Four-Dimensional Computed Tomography-Derived Radiolunate Arthrokinematics With a Case Study in Four-Corner Arthrodesis
Trentadue, Taylor P. , Thoreson, Andrew R. , Lopez, Cesar , Leng, Shuai, Amadio, Peter C. , Kakar, Sanjeev , Zhao, Kristin D. , Amadio, Peter, Kakar, Sanjeev , Trentadue, Taylor P , Trentadue, Taylor P , Leng, Shuai

HAND | August 7, 2025 | Volume: 21 | Issue: 8 | Pages: 1286-1296

10.1177/15589447251352124 Get It

Background: The radiolunate joint is conventionally thought to be spared from radiocarpal osteoarthritis, but proximal lunate degenerative changes have been noted. An investigation of radiolunate arthrokinematics in ostensibly healthy wrists may improve understanding of posttraumatic and postoperative outcomes. We hypothesize that four-dimensional computed tomography (4DCT)-derived radiolunate arthrokinematics during motion will differ between wrists with type 1 and type 2 lunates. The clinical-translational relevance of this analysis is highlighted using a 4DCT case study of scaphoid excision with 4-corner arthrodesis (SEFCA). Methods: Four-dimensional computed tomography data were collected during flexion-extension and radioulnar deviation in 19 healthy wrists (mean [SD] age: 43.6 [11.7] years, 21.1% female) and 1 wrist 3 years after SEFCA (male, 52 years). Carpal osteokinematics and joint arthrokinematics were calculated to derive median radiolunate interosseous proximities at each 4DCT-captured timepoint. Results: Median radiolunate interosseous proximities during motion are well approximated by second-order regressions in uninjured wrists. In the arthrodesed wrist, closest proximities occurred at the extremes of motion except maximum radial deviation. Conclusions: This study quantifies a normative range of median radiolunate interosseous proximities during wrist motion. The normative 4DCT datasets provide a reference range for evaluating postoperative arthrokinematics, suggesting the clinical-translational potential of dynamic imaging. The case study highlights applications for patient-level postoperative evaluation, which can be expanded to other pathologies, surgeries, or conditions in the future.
Spectral performance for iodine quantification of a dual‐source, dual‐kV photon counting detector CT
Winfree, Tim N., Treb, Kevin , Leng, Shuai, Winfree, Tim, McCollough, Cynthia, Treb, Kevin , McCollough, Cynthia H. , Leng, Shuai

Medical Physics | February 10, 2025 | Volume: 52 | Issue: 5 | Pages: 2824-2831

10.1002/mp.17679 Get It

Abstract Background Multi‐energy CT (MECT) enables quantification of material concentrations by measuring linear attenuation coefficient line integrals with multiple x‐ray spectra. Photon counting detector (PCD)‐CT utilizes a detector‐based approach for MECT that can suffer from substantial spectral overlap, resulting in amplified material quantification noise. Dual‐source dual‐kV approaches for MECT are currently utilized in some energy‐integrating detector (EID)‐CT systems and can potentially be utilized with PCD‐CT for improved spectral separation. Purpose To evaluate the iodine quantification performance of a novel dual‐source (DS)‐PCD‐CT scan mode and compare to single‐source (SS)‐PCD‐CT and DS‐EID‐CT. Materials and Methods A 30 cm × 40 cm solid water phantom with four iodine inserts (2, 5, 10, and 15 mg/mL) was scanned with the three spectral modalities: SS‐PCD‐CT with two energy thresholds, DS‐PCD‐CT (90/Sn150 kV), and DS‐EID‐CT (90/Sn150 kV). For each modality, full‐dose (12 mGy) and half‐dose scans were acquired, and images were reconstructed with filtered back‐projection using a quantitative (Qr40) kernel. When scanning in a DS configuration, the total radiation dose budget is split between two detectors, increasing the strength of a signal‐dependent filter compared to a SS acquisition. To account for this effect, the modulation transfer function (MTF) for each modality was measured from a 0.05 mm tungsten wire. A linear spatial filter was applied to the SS images to match their MTF to that of the DS images. The resulting high‐ and low‐energy images were input into an image‐domain least squares material decomposition algorithm with iodine and water as the two basis materials. Iodine quantification accuracy and noise measured from the iodine basis images were used as figures of merit, and t‐tests used to compare between modalities. Results The 10% MTF cutoffs were 0.56, 0.57, 0.60, and 0.57 lp/mm for DS‐EID‐CT, DS‐PCD‐CT, SS‐PCD‐CT, and SS‐PCD‐CT after MTF‐matching, respectively, with the SS‐PCD‐CT MTF cutoff dropping to 0.58 lp/mm at half‐dose. Without accounting for the signal‐dependent filter by matching the MTFs, the noise in iodine material basis images from SS‐PCD‐CT was 10% higher than that of DS‐EID‐CT. After matching the MTFs, the noise in the SS‐PCD‐CT iodine image was 9%–22% lower than that of the DS‐EID‐CT. The lowest iodine image noise was from the DS‐PCD‐CT, which was 39%–41% lower than the DS‐EID‐CT. The DS‐PCD‐CT noise magnitude was significantly different from the other modalities. Mean iodine quantification accuracy across all measured concentrations was within 5% for all modalities at full dose, but was only below 5% for the DS‐PCD‐CT at half‐dose. Conclusions SS‐PCD‐CT with two energy thresholds outperformed DS‐EID‐CT in terms of image noise in iodine basis images when spatial resolution was matched. DS‐PCD‐CT gave the lowest noise due to the combination of PCD technology and improved spectral separation from the different x‐ray spectra.
Spatial resolution improvements for photon counting detectors using coincidence counting and frequency weighted reconstruction
Hsieh, Scott S. , Leng, Shuai, McCollough, C, Taguchi, Katsuyuki , Leng, Shuai

Medical Physics | February 6, 2025 | Volume: 52 | Issue: 4 | Pages: 2052-2063

10.1002/mp.17664 Get It

AbstractBackgroundPhoton counting X‐ray detectors (PCDs) provide better spatial resolution than energy integrating X‐ray detectors, but even higher resolution is desired in some applications. Certain charge sharing compensation techniques such as coincidence counting preferentially detect photons that arrive at the boundary between pixels, and this could be used for subpixel localization of incident photons and enhanced spatial resolution.PurposeTo estimate improvements to spatial resolution and detective quantum efficiency that are possible when using coincidence counting for high‐resolution, non‐spectral imaging.MethodsThe modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) were estimated using numerical simulations of a two‐dimensional parallel‐beam CT system. Coincidence counters were modeled either geometrically or with Monte Carlo simulations. The geometric model consisted of narrow coincidence counters that interlaced with wider ordinary pixels, and showed that using standard filtered backprojection decreases low‐frequency DQE, but that a frequency weighting technique could be used to restore DQE. The Monte Carlo simulations were used to estimate the possible improvements that could be expected from real systems. The pixel pitch was 0.25 mm and the source apertures considered were 0, 0.125, and 0.5 mm. A numerical stent phantom was also used to illustrate possible improvements.ResultsAssuming a 0.125 mm source aperture and the Monte Carlo model, the limiting MTF (at 10%) increased from 20 to 40 lp/cm using coincidence counters. This can be explained by the increased sampling (and higher Nyquist limit) possible from coincidence counters. In the geometric model, coincidence counters are compared to conventional double sampling techniques such as in‐plane flying focal spot, and the MTF at 38 lp/cm increased from 5% to 53%. Without the frequency weighting technique, low‐frequency DQE was reduced by about 20%, but these losses are recovered with frequency weighting. Improvements are much more modest with the 0.25 mm source aperture because the system becomes source‐limited.ConclusionsCoincidence counting could be used to increase spatial resolution in PCDs. The increases in system resolution could be large if a high‐resolution X‐ray source were available.
AAPM Task Group Report 299: Quality control in multi‐energy computed tomography
Leng, Shuai, Boedeker, Kirsten , Burk, Laurel M., Dang, Hao , Li, Baojun , Madhav, Priti, Miller, Jessica R. , Nute, J, Giraldo, Juan Carlos Ramírez, Ruchala, Kenneth J., Tao, Shengzhen , Varchena, Vladimir, Vedantham, Srinivasan , Zeng, Rongping , Layman, Rick R. , Leng, Shuai , Duan, Xinhui , Jacobsen, Megan C. , Li, Ke , Little, Kevin J. , Ruchala, Ken, Zhang, Da

Medical Physics | July 29, 2024 | Volume: 51 | Issue: 10 | Pages: 7012-7037

10.1002/mp.17322 Get It

AbstractMulti‐energy computed tomography (MECT) offers the opportunity for advanced visualization, detection, and quantification of select elements (e.g., iodine) or materials (e.g., fat) beyond the capability of standard single‐energy computed tomography (CT). However, the use of MECT requires careful consideration as substantially different hardware and software approaches have been used by manufacturers, including different sets of user‐selected or hidden parameters that affect the performance and radiation dose of MECT. Another important consideration when designing MECT protocols is appreciation of the specific tasks being performed; for instance, differentiating between two different materials or quantifying a specific element. For a given task, it is imperative to consider both the radiation dose and task‐specific image quality requirements. Development of a quality control (QC) program is essential to ensure the accuracy and reproducibility of these MECT applications. Although standard QC procedures have been well established for conventional single‐energy CT, the substantial differences between single‐energy CT and MECT in terms of system implementations, imaging protocols, and clinical tasks warrant QC tests specific to MECT. This task group was therefore charged with developing a systematic QC program designed to meet the needs of MECT applications. In this report, we review the various MECT approaches that are commercially available, including information about hardware implementation, MECT image types, image reconstruction, and postprocessing techniques that are unique to MECT. We address the requirements for MECT phantoms, review representative commercial MECT phantoms, and offer guidance regarding homemade MECT phantoms. We discuss the development of MECT protocols, which must be designed carefully with proper consideration of MECT technology, imaging task, and radiation dose. We then outline specific recommended QC tests in terms of general image quality, radiation dose, differentiation and quantification tasks, and diagnostic and therapeutic applications.