Abstract Background Photon counting detector CT (PCD‐CT) has the potential to sort detected x‐ray photons into more than two energy bins to perform multi‐material decomposition using K‐edge materials without additional mathematical constraints/assumptions. The availability of multiple energy thresholds in PCD‐CT opens the possibility for unique clinical applications such as simultaneous multi‐contrast‐agent imaging. Purpose To evaluate the technical performance of a PCD‐CT system with four energy thresholds for conducting multi‐material decomposition of iodine, gadolinium, and water after a comprehensive system calibration procedure. Methods Experiments were performed on a commercial PCD‐CT scanner (NAEOTOM Alpha, Siemens Healthineers) using a research mode with four energy thresholds. Material calibration was performed by scanning contrast materials with known concentration placed in various sizes of cylindrical water‐equivalent phantoms at various tube currents and positions. From these data, per‐voxel contrast models were derived for each material by multiple linear regressions up to second order, where the predictor variables were combinations of tube current, phantom diameter, and distance to isocenter. After calibration, small (20 cm diameter) and large (30 cm × 40 cm) uniform multi‐energy CT phantoms and an anthropomorphic thorax phantom (31 cm × 39 cm), each containing bone, soft tissue, and several quantitative inserts of iodine (0.2–5.0 mg/ml), gadolinium (0.3–5.0 mg/ml), and a mixture of both (5.0 mg/ml each) were scanned using the four‐energy threshold mode at 140 kV with energy thresholds set at 20, 52, 75, and 82 keV. Images for each energy threshold were reconstructed with a filtered back‐projection algorithm and a quantitative kernel (Qr44). Subsequent image‐based material decomposition was performed on individual voxels of the energy threshold images using the models derived from the calibration process to generate water, iodine, and gadolinium basis images. Quantitative material concentrations and image noise magnitudes, and noise power spectra (NPS) were measured. Results Iodine and gadolinium concentrations above 1.25 mg/ml were visible in the material basis images in all phantoms. Averaged quantitative accuracy for iodine and gadolinium in the small, large, and thorax phantoms were 0.39 ± 0.30 mg/ml, 0.96 ± 0.53 mg/ml, and 0.53 ± 0.35 mg/ml, respectively. In the water basis images, accuracy was within 24 HU in all phantoms. Noise magnitudes in iodine and gadolinium basis images were 2.91 and 3.52 times that of the lowest energy threshold image for the small phantom, and were 6.92 and 7.17 times that of the lowest threshold image for the large phantom. Noise texture did not change between the energy threshold and material basis images for either size phantom as measured by the NPS. Conclusions After a comprehensive system calibration, a commercial PCD‐CT with four energy thresholds performed multiple material decomposition of iodine, gadolinium, and water for concentrations above 1.25 mg/ml in human‐sized phantoms. Noise amplification and quantitative accuracy from the decomposition greatly depended on object size.
Simultaneous ultra-high resolution multi-energy cardiac imaging in a dual-source photon counting detector CT system
Abstract Objectives To assess quantitative and qualitative image characteristics in phantoms and patients using a simultaneous ultra-high resolution (UHR) and multi-energy (ME) dual-source cardiac scan mode in a photon counting detector (PCD) CT scanner. Methods UHR-ME cardiac scans were performed to determine the spatial resolution and multi-energy performance. UHR reconstructions were completed to measure transverse and axial spatial resolution in terms of modulation transfer function (MTF) and slice sensitivity profile (SSP). Virtual monoenergetic images (VMIs), virtual non-contrast (VNC) images, and iodine concentration images were created using moderately sharp reconstruction kernels to assess ME performance. With IRB approval, coronary CT angiograms were acquired in 19 patients using the UHR-ME mode, from which iodine contrast-to-noise ratio (CNR) was measured. Various ME post-processing tasks were performed to show the utility of the spectral capabilities. Results VMIs showed a mean CT number error of 6.0%, while iodine accuracy was 0.71 mg/cc (root-mean-square-error). Spatial resolution matched well with a standard UHR mode. Patient images showed a trend of higher CNR at lower keV, while higher keV images showed decreased calcium blooming. ME techniques to separate iodine and calcium were used successfully. Conclusions The combination of UHR-ME cardiac mode retains UHR image quality while providing flexibility for ME post-processing. Advances in knowledge Cardiac UHR-ME PCD-CT scanning offers simultaneous UHR and ME imaging without loss of spatial or temporal resolution or quantitative accuracy.
First Clinical Photon-counting Detector CT System: Technical Evaluation
Abstract We report a comprehensive evaluation of a full field-of-view (FOV) photon-counting detector (PCD) computed tomography (CT) system using phantoms, and qualitatively assess image quality in patient examples. A whole-body PCD-CT system with 50 cm FOV, 5.76 cm z-detector coverage and two acquisition modes (standard: 144 × 0.4 mm collimation and ultra-high resolution (UHR): 120 × 0.2 mm collimation) was used in this study. Phantoms were scanned to assess image uniformity, CT number accuracy, noise power spectrum, spatial resolution, material decomposition and virtual monoenergetic imaging (VMI) performance. Four patients were scanned on the PCD-CT system with matched or lower radiation dose than their prior clinical CT scans performed using energy-integrating detector (EID) CT, and the potential clinical impact of PCD-CT was qualitatively evaluated. Phantom results showed water CT numbers within ±5 HU, and image uniformity measured between peripheral and central regions-of-interests to be within ±5 HU. For the UHR mode using a dedicated sharp kernel, the cut-off spatial frequency was 40 line-pairs cm −1 , which corresponds to a 125 μ m limiting in-plane spatial resolution. The full-width-at-half-maximum for the section sensitivity profile was 0.33 mm for the smallest slice thickness (0.2 mm) using the UHR mode. Material decomposition in a multi-energy CT phantom showed accurate material classification, with a root-mean-squared-error of 0.3 mg cc −1 for iodine concentrations (2–15 mg cc −1 ) and 14.2 mg cc −1 for hydroxyapatite concentrations (200 and 400 mg cc −1 ). The average percent error for CT numbers corresponding to the iodine concentrations in VMI (40–70 keV) was 2.75%. Patient PCD-CT images demonstrated better delineation of anatomy for chest and temporal bone exams performed with the UHR mode, which allowed the use of very sharp kernels not possible with EID-CT. VMI and virtual non-contrast images generated from a patient head CT angiography exam using the standard acquisition mode demonstrated the multi-energy capability of the PCD-CT system.
Energy‐integrating‐detector multi‐energy CT: Implementation and a phantom study
PurposeMulti‐energy computed tomography (MECT) has a great potential to enable many novel clinical applications such as simultaneous multi‐contrast imaging. The purpose of this study was to implement triple‐beam MECT on a traditional energy‐integrating‐detector (EID) CT platform (EID‐MECT).MethodsThis was accomplished by mounting a z‐axis split‐filter (0.05 mm Au, 0.6 mm Sn) on Tube A of a dual‐source EID CT scanner. With the two split x‐ray beams from Tube A and the third beam from Tube B, three beams with different x‐ray spectra can be simultaneously acquired. With Tube B operated at 70 or 80 kV and Tube A at 120 or 140 kV, four different triple‐beam configurations were calibrated for MECT measurements: 70/Au120/Sn120, 80/Au120/Sn120, 70/Au140/Sn140, and 80/Au140/Sn140 kV. Iodine (I), gadolinium (Gd), bismuth (Bi) samples, and their mixtures were prepared for 2 three‐material‐decomposition tasks and 1 four‐material‐decomposition task. For each task, samples were placed in a water phantom and scanned using each of the four triple‐beam configurations. For comparison, the same phantom was also scanned using three other dual‐energy CT (DECT) or MECT technologies: twin‐beam DECT (TB‐DECT), dual‐source DECT (DS‐DECT), and photon‐counting‐detector CT (PCD‐CT), all with optimal x‐ray spectrum settings and at equal volume CT dose index (CTDIvol). The phantom for four‐material decomposition (I/Gd/Bi/Water imaging) was scanned using the PCD‐CT only (140 kV with 25, 50, 75, and 90 keV). Image‐based material decomposition was performed to acquire material‐specific images, on which the mean basis material concentrations and noise levels were measured and compared across all triple‐beam configurations in EID‐MECT and various DECT/MECT systems.ResultsThe optimal triple‐beam configuration was task‐dependent with 70/Au120/Sn120, 70/Au140/Sn140, and 70/Au120/Sn120 kV for I/Gd/Water, I/Bi/Water, and I/Gd/Bi/Water material decomposition tasks, respectively. At equal radiation dose level, EID‐MECT provided comparable or better quantification accuracy in material‐specific images for all three material decomposition tasks, compared to EID‐based DECT and PCD‐CT systems. In terms of noise level comparison, EID‐MECT‐derived material‐specific images showed lower noise levels than TB‐DECT and DS‐DECT, but slightly higher than that from PCD‐CT in I/Gd/Water imaging. For I/Bi/Water imaging, EID‐MECT showed a comparable noise level to DS‐DECT, and a much lower noise level than TB‐DECT and PCD‐CT in all material‐specific images. For the four‐material decomposition task involving I/Gd/Bi/Water, the bismuth‐specific image derived from EID‐MECT was slightly noisier, but both iodine‐ and gadolinium‐specific images showed much lower noise levels in comparison to PCD‐CT.ConclusionsFor the first time, an EID‐based MECT system that can simultaneously acquire three x‐ray spectra measurements was implemented on a clinical scanner, which demonstrated comparable or better imaging performance than existing DECT and MECT systems.
Technical Note: kV‐independent coronary calcium scoring: A phantom evaluation of score accuracy and potential radiation dose reduction
Purpose To determine the accuracy of CT number and calcium score of a kV‐independent technique based on an artificial 120 kV reconstruction, and its potential to reduce radiation dose. Methods Anthropomorphic chest phantoms were scanned on a third‐generation dual‐source CT system equipped with the artificial 120 kV reconstruction. First, a phantom module containing a 20‐mm diameter hydroxyapatite (HA) insert was scanned inside the chest phantoms at different tube potentials (70–140 kV) to evaluate calcium CT number accuracy. Next, three small HA inserts (diameter/length = 5 mm) were inserted into a pork steak and scanned inside the phantoms to evaluate calcium score accuracy at different kVs. Finally, the same setup was scanned using automatic exposure control (AEC) at 120 kV, and then with automatic kV selection (auto‐kV). Phantoms were also scanned at 120 kV using a size‐dependent mA chart. CT numbers of soft tissue and calcium were measured from different kV images. Calcium score of each small HA insert was measured using commercial software. Results The CT number difference from 120 kV was small with tube potentials from 90 to 140 kV for both soft tissue and calcium (maximal difference of 4/5 HU, respectively). Consistent calcium scores were obtained from images of different kVs compared to 120 kV, with a relative difference <8%. Auto‐kV provided a 25–34% dose reduction compared to AEC alone. Conclusion A kV‐independent calcium scoring technique can produce artificial 120 kV images with consistent soft tissue and calcium CT numbers compared to standard 120 kV examinations. When coupled with auto‐kV, this technique can reduce radiation by 25–34% compared to that with AEC alone, while providing consistent calcium scores as that of standard 120 kV examinations.
Individualized Delay for Abdominal Computed Tomography Angiography Bolus-Tracking Based on Sequential Monitoring: Increased Aortic Contrast Permits Decreased Injection Rate and Lower Iodine Dose
Objective The aim of this study was to determine if computed tomography (CT) angiography using an individualized transition delay (CTA-ID) would facilitate reductions in injection rate and iodine dose. Methods The CTA-ID was performed in 20 patients with routine injection rate and iodine dose; 20 patients with injection rate lowered by 1 mL/s; and 40 patients with injection rate lowered by 1 mL/s with 29% less iodine. Routine CTAs in the same or size-matched patients served as controls. Diagnostic image quality and intra-arterial CT numbers were assessed. Results The median transition delay between aortic threshold and CTA-ID image acquisition was significantly longer than with conventional bolus tracking (mean increase, 13.3 seconds; P < 0.0001), with image quality being the same or better. Intra-arterial CT numbers were 200 Hounsfield units or greater for 80 of 80 CTA-ID, but not for 6 of 49 (12%) internal control or for 11 of 80 (14%) size-matched control patients. Conclusion The CTA-ID bolus-tracking software alters transition delays to permit diagnostic CTA examinations despite slower injection rate and less iodine.
Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets
Abstract Photon-counting computed tomography (PCCT) uses a photon counting detector to count individual photons and allocate them to specific energy bins by comparing photon energy to preset thresholds. This enables simultaneous multi-energy CT with a single source and detector. Phantom studies were performed to assess the spectral performance of a research PCCT scanner by assessing the accuracy of derived images sets. Specifically, we assessed the accuracy of iodine quantification in iodine map images and of CT number accuracy in virtual monoenergetic images (VMI). Vials containing iodine with five known concentrations were scanned on the PCCT scanner after being placed in phantoms representing the attenuation of different size patients. For comparison, the same vials and phantoms were also scanned on 2nd and 3rd generation dual-source, dual-energy scanners. After material decomposition, iodine maps were generated, from which iodine concentration was measured for each vial and phantom size and compared with the known concentration. Additionally, VMIs were generated and CT number accuracy was compared to the reference standard, which was calculated based on known iodine concentration and attenuation coefficients at each keV obtained from the U.S. National Institute of Standards and Technology (NIST). Results showed accurate iodine quantification (root mean square error of 0.5 mgI/cc) and accurate CT number of VMIs (percentage error of 8.9%) using the PCCT scanner. The overall performance of the PCCT scanner, in terms of iodine quantification and VMI CT number accuracy, was comparable to that of EID-based dual-source, dual-energy scanners.
Dual energy CT kidney stone differentiation in photon counting computed tomography
Feasibility of Discriminating Uric Acid From Non–Uric Acid Renal Stones Using Consecutive Spatially Registered Low- and High-Energy Scans Obtained on a Conventional CT Scanner