Back to Authors

Lee, Yong S.

https://orcid.org/0009-0005-9707-144X

Mayo Clinic

Mayo Clinic

Citations 17

Feasibility of thin-slice, low noise images created using multi-kernel synthesis to replace multiple image series in head CT
Diehn, Felix E. , Nagelschneider, Alex A. , Passe, Theodore J. , Nelson, Brandon , Cardona, Daniel Gomez , Huber, Nathan R. , Missert, Andrew D, Yu, Lifeng , Johnson, Matthew P. , Holmes, David R. , Lee, Yong S. , Thorne, Jamison E. , Diehn, Felix E , DeLone, David R. , Nelson, Brandon J, Gomez Cardona, Daniel G , Thorne, Jamison E , Fletcher, Joel G , Inoue, Akitoshi , Missert, Andrew D, Yu, Lifeng , McCollough, Cynthia H. , Fletcher, Joel G.

Acta Radiologica | October 17, 2024 | Volume: 65 | Issue: 11 | Pages: 1411-1421

10.1177/02841851241280365 Get It

Background SynthesiZed Improved Resolution and Concurrent nOise reductioN (ZIRCON) is a multi-kernel synthesis method that creates a single series of thin-slice computed tomography (CT) images displaying low noise and high spatial resolution, increasing reader efficiency and minimizing partial volume averaging. Purpose To compare the diagnostic performance of a single set of ZIRCON images to two routine clinical image series using conventional CT head and bone reconstruction kernels for diagnosing intracranial findings and fractures in patients with trauma or suspected acute neurologic deficit. Material and Methods In total, 50 patients underwent clinically indicated head CT in the ER (15 normal, 35 abnormal cases). A non-reader neuroradiologist established the reference standard. Three neuroradiologists reviewed two routine clinical series (head and bone kernels) and a single ZIRCON series, detecting intracranial findings or fractures and rating confidence (0–100). Sensitivity, specificity, and jackknife free-response receiver operating characteristic (JAFROC) figure of merit (FOM) were compared (limit of non-inferiority: −0.10). Results ZIRCON and conventional images demonstrated comparable performance for fractures (sensitivity: 51.5% vs. 54.5%; specificity: 40.2% vs. 34.2%) and intracranial findings (sensitivity: 88.2% vs. 91.4%; specificity: 77.2% vs. 73.7%).The estimated difference of JAFROC FOM demonstrated ZIRCON non-inferiority for acute pathologies overall (0.003 [95% CI=−0.051–0.057]) and fractures (0.048 [95% CI=−0.050–0.145]) but not for intracranial findings alone (−0.024 [95% CI=−0.100–0.052]). Conclusion Thin-slice, low noise, and high spatial resolution images can be created to display intracranial findings and fractures replacing multiple images series in head CT with similar performance. Future studies in more patients and further algorithmic development are warranted.
Infrapopliteal Segments on Lower Extremity CTA: Prospective Intraindividual Comparison of Energy-Integrating Detector CT and Photon-Counting Detector CT
Yalon, Mariana , Thorne, Jamison E. , Lee, Yong S. , Johnson, Matthew P. , Esquivel, Andrea , Rajiah, Prabhakar Shantha, Inoue, Akitoshi , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Rajiah, Prabhakar

American Journal of Roentgenology | December 20, 2023 | Volume: 222 | Issue: 3 | Pages: No page available

10.2214/ajr.23.29778 Get It

Durable Response in Patients With Refractory Fistulizing Perianal Crohn’s Disease Using Autologous Mesenchymal Stem Cells on a Dissolvable Matrix: Results from the Phase I Stem Cell on Matrix Plug Trial
Dozois, Eric J. , Dietz, Allan B. , Lee, Yong S. , Friton, Jessica, Faubion, William A. , Friton, Jessica J, Dietz, Allan B , Lightner, Amy L. , Fletcher, Joel G.

Diseases of the Colon & Rectum | December 20, 2022 | Volume: 66 | Issue: 2 | Pages: 243-252

10.1097/dcr.0000000000002579 Get It

BACKGROUND: Refractory perianal Crohn’s disease remains notoriously difficult to treat. We developed a novel technology using a commercially available bioabsorbable fistula plug to deliver autologous adipose-derived mesenchymal stem cells. OBJECTIVE: This study aimed to assess therapeutic safety and feasibility in the completed STOMP (stem cells on matrix plugs) phase 1 clinical trial. DESIGN: Prospective single-arm phase I clinical trial. SETTING: Tertiary academic medical center. PATIENTS: Adults (aged 18–65 y) with complex single-tract Crohn’s disease perianal fistula who have failed conventional therapy were included in this study. INTERVENTION: Autologous adipose-derived mesenchymal stem cells were isolated, ex vivo culture expanded, and seeded onto a commercially available bioabsorbable fistula plug. Six weeks later, patients returned to the operating room for removal of the seton and placement of the stem cell-loaded plug. MAIN OUTCOME MEASURES: Patients were followed up for a total of 8 visits through 12 months. Safety was the primary end point; clinical healing and MRI response were secondary end points. RESULTS: Twenty patients (12 females; mean age 36 y) were treated with the stem cell–loaded plug. Of the 20 patients enrolled, 3 were not included in the 12-month analysis because of study withdrawal. Through 12 months, no patient experienced a serious adverse event related to the stem cell–loaded plug. Four patients experienced 7 serious adverse events and 12 patients experienced 22 adverse events. Complete clinical healing occurred in 14 of 18 patients at 6 months and 13 of 17 patients at 12 months. MRI response was observed in 12 of 18 patients at 6 months. LIMITATIONS: The main limitations were the small sample size and restrictive inclusion criteria. CONCLUSIONS: A stem cell–loaded plug can safely and effectively deliver cell-based therapy for patients with single-tract fistulizing perianal Crohn’s disease. See Video Abstract at http://links.lww.com/DCR/C70. RESPUESTA DURADERA OBSERVADA EN PACIENTES CON ENFERMEDAD DE CROHN PERIANAL FISTULIZANTE REFRACTARIA MEDIANTE EL USO DE CÉLULAS MADRE MESENQUIMALES AUTÓLOGAS EN UNA MATRIZ DISOLUBLE: RESULTADOS DEL ENSAYO DE FASE I STEM CELL ON MATRIX PLUG ANTECEDENTES: La enfermedad de Crohn perianal refractaria sigue siendo notoriamente difícil de tratar. Desarrollamos una tecnología novedosa utilizando un tapón de fístula bioabsorbible disponible comercialmente para administrar células madre mesenquimales derivadas de tejido adiposo autólogo. OBJETIVO: Evaluar la seguridad y viabilidad terapéutica en el ensayo finalizado STOMP. DISEÑO: Ensayo clínico prospectivo de fase I de un solo brazo. AJUSTE: Centro médico académico terciario. PACIENTES: Adultos (18-65) con fístula perianal compleja de la enfermedad de Crohn de un solo tracto que han fracasado con la terapia convencional. INTERVENCIÓN: Se aislaron células madre mesenquimales derivadas de tejido adiposo autólogo, se expandieron en cultivo ex vivo y se sembraron en un tapón de fístula bioabsorbible disponible comercialmente. Seis semanas después, los pacientes regresaron al quirófano para retirar el setón y colocar el tapón cargado de células madre. PRINCIPALES MEDIDAS DE RESULTADO: Los pacientes fueron seguidos durante un total de 8 visitas durante 12 meses. La seguridad fue el criterio principal de valoración; la curación clínica y la respuesta a la resonancia magnética fueron criterios de valoración secundarios. RESULTADOS: Veinte pacientes (12 mujeres, edad media 36 años) fueron tratados con el tapón cargado de células madre. De los 20 pacientes inscritos, tres no se incluyeron en el análisis de 12 meses porque se retiraron del estudio. A lo largo de 12 meses, ningún paciente experimentó un evento adverso grave relacionado con el tapón cargado de células madre. Cuatro pacientes experimentaron 7 eventos adversos graves y 12 pacientes experimentaron 22 eventos adversos. La curación clínica completa ocurrió en 14 de 18 pacientes a los 6 meses y en 13 de 17 pacientes a los 12 meses. La respuesta a la resonancia magnética se observó en 12 de 18 pacientes a los 6 meses. LIMITACIONES: Las principales limitaciones son el tamaño pequeño de la muestra y los criterios de inclusión restrictivos. CONCLUSIONES: Un tapón cargado de células madre se puede administrar de manera segura y efectiva, una terapia basada en células para pacientes con enfermedad de Crohn perianal fistulizante de un solo tracto. Consule Video Resumen en http://links.lww.com/DCR/C70. (Traducción— Dr. Yesenia Rojas-Khalil)
Diagnostic Performance in Low- and High-Contrast Tasks of an Image-Based Denoising Algorithm Applied to Radiation Dose–Reduced Multiphase Abdominal CT Examinations
Voß, Benjamin, Lee, Nam Ju, Takahashi, Hiroaki , Kozaka, Kazuto , Heiken, Jay P. , Ehman, Eric C. , Vasconcelos, Rogerio N., Fidler, Jeff L. , Lee, Yong S. , Mileto, Achille , Johnson, Matthew P. , Baer‐Beck, Matthias, Weber, Nikkole M. , Michalak, Gregory J. , Halaweish, Ahmed F., Carter, Rickey E. , Inoue, Akitoshi , Voss, Benjamin A, Vasconcelos, Rogerio, Halaweish, Ahmed, Carter, Rickey E , Takahashi, Hiroaki , Lee, Nam Ju, Fidler, Jeff L. , McCollough, Cynthia H. , Fletcher, Joel G.

American Journal of Roentgenology | June 22, 2022 | Volume: 220 | Issue: 1 | Pages: 73-85

10.2214/ajr.22.27806 Get It

Estimating the Clinical Impact of Photon-Counting-Detector CT in Diagnosing Usual Interstitial Pneumonia
Inoue, Akitoshi , Johnson, Tucker F. , White, Darin , Cox, Christian W. , Hartman, Thomas E. , Thorne, Jamison E. , Shanblatt, Elisabeth R. , Johnson, Matthew P. , Carter, Rickey E. , Lee, Yong S. , Fletcher, Joel G , Carter, Rickey E , Inoue, Akitoshi , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Investigative Radiology | June 15, 2022 | Volume: 57 | Issue: 11 | Pages: 734-741

10.1097/rli.0000000000000888 Get It

Objective The aim of this study was to evaluate the clinical impact of a higher spatial resolution, full field-of-view investigational photon-counting detector computed tomography (PCD-CT) on radiologist confidence in imaging findings and diagnosis of usual interstitial pneumonia (UIP) compared with conventional energy-integrating detector CT (EID-CT). Materials and Methods Patients suspected of interstitial lung disease were scanned on a PCD-CT system after informed consent and a clinically indicated EID-CT. In 2 sessions, 3 thoracic radiologists blinded to clinical history and scanner type evaluated CT images of the right and left lungs separately on EID- or PCD-CT, reviewing each lung once/session, rating confidence in imaging findings of reticulation, traction bronchiectasis, honeycombing, ground-glass opacities (GGOs), mosaic pattern, and lower lobe predominance (100-point scale: 0–33, likely absent; 34–66, indeterminate; 67–100, likely present). Radiologists also rated confidence for the probability of UIP (0–20, normal; 21–40, inconsistent with UIP; 41–60, indeterminate UIP; 61–81; probable UIP; 81–100, definite UIP) and graded image quality. Because a confidence scale of 50 represented completely equivocal findings, magnitude score (the absolute value of confidence scores from 50) was used for analysis (higher scores were more confident). Image noise was measured for each modality. The magnitude score was compared using linear mixed effects regression. The consistency of findings and diagnosis between 2 scanners were evaluated using McNemar test and weighted κ statistics, respectively. Results A total of 30 patients (mean age, 68.8 ± 11.0 years; M:F = 18:12) underwent conventional EID-CT (median CTDIvol, 7.88 mGy) and research PCD-CT (median CTDIvol, 6.49 mGy). The magnitude scores in PCD-CT were significantly higher than EID-CT for imaging findings of reticulation (40.7 vs 38.3; P = 0.023), GGO (34.4 vs 31.7; P = 0.019), and mosaic pattern (38.6 vs 35.9; P = 0.013), but not for other imaging findings (P ≥ 0.130) or confidence in UIP (34.1 vs 22.2; P < 0.059). Magnitude score of probability of UIP in PCD-CT was significantly higher than EID-CT in one reader (26.0 vs 21.5; P = 0.009). Photon-counting detector CT demonstrated a decreased number of indeterminate GGO (17 vs 26), an increased number of unlikely GGO (74 vs 50), and an increased number of likely reticulations (140 vs 130) relative to EID-CT. Interobserver agreements among 3 readers for imaging findings and probability of UIP were similar between PCD-CT and EID-CT (intraclass coefficient: 0.507–0.818 vs 0.601–0.848). Photon-counting detector CT had higher scores in overall image quality (4.84 ± 0.38) than those in EID-CT (4.02 ± 0.40; P < 0.001) despite increased image noise (mean 85.5 vs 36.1 HU). Conclusions Photon-counting detector CT provided better image quality and improved the reader confidence for presence or absence of imaging findings of reticulation, GGO, and mosaic pattern with idiosyncratic improvement in confidence in UIP presence.
Letter: normalizing the ileoanal pouch—more than a one‐step technique. Authors' reply
Quinn, Kevin P. , Busciglio, Irene, Burton, Duane D. , Lee, Yong S. , Heiken, Jay P. , Sheedy, Shannon P. , Raffals, Laura E. , Busciglio, Irene A, Inoue, Akitoshi , Raffals, Laura , Fletcher, Joel G.

Alimentary Pharmacology & Therapeutics | June 11, 2022 | Volume: 56 | Issue: 1 | Pages: 176-177

10.1111/apt.16988 Get It

LINKED CONTENTThis article is linked to Quinn et al papers. To view these articles, visit https://doi.org/10.1111/apt.16859 and https://doi.org/10.1111/apt.16954
Editorial: what is normal function of a pelvic pouch? Authors' reply
Quinn, Kevin P. , Busciglio, Irene, Burton, Duane D. , Lee, Yong S. , Heiken, Jay P. , Sheedy, Shannon P. , Raffals, Laura E. , Busciglio, Irene A, Inoue, Akitoshi , Raffals, Laura , Fletcher, Joel G.

Alimentary Pharmacology & Therapeutics | May 11, 2022 | Volume: 55 | Issue: 11 | Pages: 1454-1455

10.1111/apt.16944 Get It

LINKED CONTENTThis article is linked to Quinn et al papers. To view these articles, visit https://doi.org/10.1111/apt.16859 and https://doi.org/10.1111/apt.16916
Defining normal pouch function in patients with ileal pouch‐anal anastomosis: a pilot study
Quinn, Kevin P. , Busciglio, Irene, Burton, Duane D. , Lee, Yong S. , Heiken, Jay P. , Sheedy, Shannon P. , Raffals, Laura E. , Busciglio, Irene A, Inoue, Akitoshi , Raffals, Laura , Fletcher, Joel G.

Alimentary Pharmacology & Therapeutics | March 11, 2022 | Volume: 55 | Issue: 12 | Pages: 1560-1568

10.1111/apt.16859 Get It

SummaryBackgroundMost patients experience good functional outcomes following ileal pouch‐anal anastomosis (IPAA) for ulcerative colitis.AimWe aimed to determine if asymptomatic patients with an IPAA had findings consistent with normal defecation on standard objective anorectal tests.MethodsPatients 18–65 years old with IPAA and self‐reported healthy pouch function were recruited. Patients with chronic pouchitis, Crohn’s disease, anastomotic stricture, or indication for IPAA other than ulcerative or indeterminate colitis were excluded. Patients underwent an interview with an abbreviated Rome Questionnaire followed by high‐resolution ano‐pouch manometry, balloon expulsion test, pouch barostat, and magnetic resonance (MR) defecography.ResultsTwenty patients completed all testing. Six patients were excluded from the final analysis due to symptoms suggestive of pouch evacuation disorder on the abbreviated Rome Questionnaire (n = 2), structural abnormality on MR imaging (n = 3), or both (n = 1). Of the remaining 14 patients, mean anal resting pressure during high‐resolution manometry was 72 ± 16 mmHg, mean anal squeeze pressure was 247 ± 69 mmHg, and mean pouch‐anal gradient during the simulated evacuation was −27 ± 37 mmHg. The meantime to balloon expulsion was 54 seconds. During dynamic MR defecography, the mean descent of ano‐pouch junction was 2.6 cm, and mean pouch evacuation was 44.5% and 74.2% pre‐ and posttoilet phase, respectively.ConclusionsA substantial proportion of patients with IPAA and self‐reported healthy pouch function have anatomic and/or functional abnormalities of the pouch. In asymptomatic IPAA patients with an anatomically normal pouch, we have proposed normal parameters for high‐resolution ano‐pouch manometry, time to balloon expulsion, pouch barostat, and MR defecography.
CT or MR Enterography to Assess Response During Vedolizumab Therapy for Small Bowel Crohn’s Disease
Kwapisz, Lukasz , Bruining, David H. , Lee, Yong S. , Edwards, Phillip K , Holmes, David R. , Carter, Rickey E. , Siegelman, Jenifer , Fletcher, Joel G. , Inoue, Akitoshi , Fletcher, Joel G , Carter, Rickey E

Crohn's & Colitis 360 | February 1, 2022 | Volume: 4 | Issue: 1 | Pages: No page available

10.1093/crocol/otac003 Get It

Abstract Background To describe response to therapy of small bowel (SB) Crohn’s disease (CD) at CT or MR enterography (CTE/MRE) in patients on vedolizumab. Methods Patients with SB CD who underwent CTE/MRE exams greater than 12 months apart on vedolizumab therapy were included. Length (in cm) and inflammation severity (EMBARK score) of inflamed SB segments were assessed. Changes in inflammation length of 3.4 cm or greater or inflammation severity of 2 EMBARK points or greater was categorized as response or progression, as appropriate, with development of newly inflamed segments, strictures, or penetrating complications also indicating progression. Patients not meeting the criteria for response or progression were categorized as having stable disease. Results Of 36 SB CD patients, the large majority had prior surgery (86%; 31), anti-TNF use (92%; 33), and internal penetrating (78%; 28) disease. Thirty-two patients had paired baseline and follow-up CTE/MRE exams without interval surgery, with clinical response observed in 24/32 (75%). Based on imaging response criteria, 22% (7/32; 95% CI: 9%–40%) had response, 50% (16/32; 95% CI: 32%–68%) were stable, and 28% (9/32; 95% CI: 14%–47%) had disease progression. Fifty-six percent of (18/32; 95% CI: 38%–74%) patients had clinical improvement with response or stable disease by imaging. Patients with stable disease had shorter median baseline lengths of SB inflammation (P = .012). Proportion of patients with colonic inflammation, perianal disease, or penetrating complications did not change. Conclusions Most patients on vedolizumab for over 12 months demonstrated response or stable SB disease when using objective cross-sectional radiologic imaging criteria using CTE/MRE.
Impact of dual-energy 50-keV virtual monoenergetic images on radiologist confidence in detection of key imaging findings of small hepatocellular carcinomas using multiphase liver CT
Voß, Benjamin, Khandelwal, Ashish , Wells, Michael , Venkatesh, Sudhakar K. , Lee, Yong S. , Johnson, Matthew P. , Fletcher, Joel G. , Voss, Benjamin A, Wells, Michael L, Inoue, Akitoshi , Fletcher, Joel G , Venkatesh, Sudhakar K

Acta Radiologica | November 1, 2021 | Volume: 63 | Issue: 11 | Pages: 1443-1452

10.1177/02841851211052993 Get It

Background Dual-energy virtual monoenergetic images can increase iodine signal, potentially increasing the conspicuity of hepatic masses. Purpose To determine if dual-energy 50-keV virtual monoenergetic images improve visualization of key imaging findings or diagnostic confidence for small (≤2 cm) hepatocellular carcinomas (HCC) at multiphase, contrast-enhanced liver computed tomography (CT). Material and Methods Patients with chronic liver disease underwent multiphase dual-energy CT imaging for HCC, with late arterial and delayed phase dual-energy 50-keV images reconstructed. Two non-reader subspecialized gastrointestinal (GI) radiologists established the reference standard, determining the location and diagnosis of all hepatic lesions using predetermined criteria. Three GI radiologists interpreted mixed kV CT images without or with dual-energy 50-keV images. Radiologists identified potential HCCs and rated their confidence (0–100 scales) in imaging findings of arterial enhancement, enhancing capsule, tumor washout, and LI-RADS 5 (2018) category. Results In total, 45 patients (14 women; mean age = 59.5 ± 10.9 years) with chronic liver disease were included. Of them, 19 patients had 25 HCCs ≤2 cm (mean size = 1.5 ± 0.4 cm). There were 17 LI-RADS 3 and 4 lesions and 19 benign lesions. Reader confidence in imaging findings of arterial enhancement, enhancing capsule, and non-peripheral washout significantly increased with dual-energy images ( P ≤ 0.022). Overall confidence in HCC diagnosis increased significantly with dual-energy 50-keV images (52.4 vs. 68.8; P = 0.001). Dual-energy images demonstrated a slight but significant decrease in overall image quality. Conclusion Radiologist confidence in key imaging features of small HCCs and confidence in imaging diagnosis increases with use of dual-energy 50-keV images at multiphase, contrast-enhanced liver CT.