Diagnostic Performance in Low- and High-Contrast Tasks of an Image-Based Denoising Algorithm Applied to Radiation Dose–Reduced Multiphase Abdominal CT Examinations
AbstractPurposeThe purpose of this work is to evaluate the scaled computed tomography (CT) number accuracy of an artificial 120 kV reconstruction technique based on phantom experiments in the context of radiation therapy planning.MethodsAn abdomen‐shaped electron density phantom was scanned on a clinical CT scanner capable of artificial 120 kV reconstruction using different tube potentials from 70 to 150 kV. A series of tissue‐equivalent phantom inserts (lung, adipose, breast, solid water, liver, inner bone, 30%/50% CaCO3, cortical bone) were placed inside the phantom. Images were reconstructed using a conventional quantitative reconstruction kernel as well as the artificial 120 kV reconstruction kernel. Scaled CT numbers of inserts were measured from images acquired at different kVs and compared with those acquired at 120 kV, which were deemed as the ground truth. The relative error was quantified as the percentage deviation of scaled CT numbers acquired at different tube potentials from their ground truth values acquired at 120 kV.ResultsScaled CT numbers measured from images reconstructed using the conventional reconstruction demonstrated a strong kV‐dependence. The relative error in scaled CT numbers ranged from 0.6% (liver insert) to 31.1% (cortical bone insert). The artificial 120 kV reconstruction reduced the kV dependence, especially for bone tissues. The relative error in scaled CT number was reduced to 0.4% (liver insert) and 2.6% (30% CaCO3 insert) using this technique. When tube potential selection was limited to the range of 90 to 150 kV, the relative error was further restrained to <1.2% for all tissue types.ConclusionPhantom results demonstrated that using the artificial 120 kV technique, it was feasible to acquire raw projection data at the desired tube potential and then reconstruct images with scaled CT numbers comparable to those obtained directly at 120 kV. In radiotherapy applications, this technique may allow optimization of tube potential without complicating clinical workflow by eliminating the necessity of maintaining multiple sets of CT calibration curves.
Preconditioning with Foam-mediated External Suction on Flap Microvasculature and Perfusion in a Rodent Model
Background: Foam-mediated external suction (FMES) has previously shown to improve tissue microcirculation. We hypothesized that preconditioning fasciocutaneous perforator flaps with FMES would augment perfusion and demonstrate greater capillary recruitment. Methods: Gluteal perforator flaps were designed on sixteen 400 g rats. Continuous FMES at −125 mm Hg was applied on one side (intervention) to precondition tissue for 5 days, with the contralateral side as a paired control. In group A, we assessed changes following pretreatment, after surgery, and 7 days postprocedure, and in group B, we evaluated changes during preconditioning alone. In group A (N = 8), control and intervention flaps were assessed using laser-assisted indocyanine green fluorescence angiography. In group B, flap regions were assessed using 4-dimensional computed tomographic angiography. All flaps were analyzed for microvessel density using micro–computed tomography and histological assessment using hematoxylin and eosin and CD3 immunohistochemistry. Results: Thirty-two flaps were included in this study (N = 16 intervention and matched controls). Four-dimensional computed tomographic angiography demonstrated 17% greater tissue perfusion in preconditioned flaps (mean, 78.7 HU; SD, 8.8) versus controls (mean, 67.3 HU; SD, 15.7; P < 0.01). Laser-assisted indocyanine green fluorescence angiography showed a 30% higher mean absolute intensity in preconditioned flaps versus controls (P < 0.01). Postsurgery mean absolute intensity in preconditioned flaps remained 21% higher than in controls (P = 0.03). Preconditioned flaps demonstrated a 2-fold increase in mean vessel volume of 9.1 mm3 (SD, 7) versus 4.5 mm3 (SD, 3) in controls (P = 0.04); there was a 33% higher mean area fraction of CD31 in preconditioned flaps, 3.9% (SD, 3) versus 2.9% (SD, 3) in controls (P = 0.03). Conclusion: FMES preconditioning has the potential to augment vascularity of tissue for flap harvest; however, further experimental studies are required to optimize strategies and evaluate long-term effects for clinical applications.
Spatial Accuracy of a Clinically Established Noninvasive Electrocardiographic Imaging System for the Detection of Focal Activation in an Intact Porcine Model
Background: Noninvasive electrocardiographic imaging (ECGi) is used clinically to map arrhythmias before ablation. Despite its clinical use, validation data regarding the accuracy of the system for the identification of arrhythmia foci is limited. Methods: Nine pigs underwent closed-chest placement of endocardial fiducial markers, computed tomography, and pacing in all cardiac chambers with ECGi acquisition. Pacing location was reconstructed from biplane fluoroscopy and registered to the computed tomography using the fiducials. A blinded investigator predicted the pacing location from the ECGi data, and the distance to the true pacing catheter tip location was calculated. Results: A total of 109 endocardial and 9 epicardial locations were paced in 9 pigs. ECGi predicted the correct chamber of origin in 85% of atrial and 92% of ventricular sites. Lateral locations were predicted in the correct chamber more often than septal locations (97% versus 79%, P =0.01). Absolute distances in space between the true and predicted pacing locations were 20.7 (13.8–25.6) mm (median and [first–third] quartile). Distances were not significantly different across cardiac chambers. Conclusions: The ECGi system is able to correctly identify the chamber of origin for focal activation in the vast majority of cases. Determination of the true site of origin is possible with sufficient accuracy with consideration of these error estimates.
Determination of iodine detectability in different types of multiple-energy images for a photon-counting detector computed tomography system
Reappraisal of Perforasomes of the Superficial Femoral, Descending Genicular, and Saphenous Arteries and Clinical Applications to Locoregional Reconstruction
Background: The superficial femoral artery and medial thigh region has been an underused donor site for perforator flaps. This study evaluated perforasomes of the superficial femoral artery and its principal branches to review the clinical applications for locoregional reconstruction. Methods: Twenty-six fresh cadaveric lower extremities were dissected. Perforator size and anatomical course from the superficial femoral artery, descending genicular artery, and saphenous artery branch were documented. Perforators were selectively injected with iodinated contrast to assess vascular territories using computed tomography. A retrospective chart review was conducted on consecutive patients (2014 to 2015). Results: One hundred thirty perforators were mapped in the medial thigh region. Eleven extended medial thigh perforator flaps and 15 hemicircumferential flaps were harvested. The mean distance from the joint line was 16.7 ± 7.3 cm. Perforators arose from the superficial femoral artery (62 percent), saphenous artery branch (23 percent), and descending genicular artery (15 percent). Superficial femoral artery perforators were located around the mid and proximal thigh region (p < 0.001). The median perforasome surface area was 244 cm2, representing 36 percent in hemithigh flaps with preferential filling in the anteromedial region. Proximal perforasomes were the smallest. Perforasome areas based on vessel origin were comparable; however, saphenous artery perforators had a broader perforasome compared with descending genicular (p = 0.01) and superficial femoral artery perforators (p = 0.04). Six clinical case examples were presented for knee, thigh, and lower leg reconstruction. Conclusions: The superficial femoral artery or its branches can provide nontraditional reconstructive perforator flap options in regional reconstruction. They can be simple to harvest using a free-style approach, do not require preoperative imaging, offer a one-stage reconstructive method with low morbidity, and obviate the need for microsurgery or muscle flaps.
Clinical Assessment of Metal Artifact Reduction Methods in Dual-Energy CT Examinations of Instrumented Spines
Purpose Photon counting detectors (PCDs) are being introduced in advanced x‐ray computed tomography (CT) scanners. From a single PCD‐CT acquisition, multiple images can be reconstructed, each based on only a part of the original x‐ray spectrum. In this study, we investigated whether PCD‐CT can be used to estimate stopping power ratios (SPRs) for proton therapy treatment planning, both by comparing to other SPR methods proposed for single energy CT (SECT) and dual energy CT (DECT) as well as to experimental measurements. Methods A previously developed DECT‐based SPR estimation method was adapted to PCD‐CT data, by adjusting the estimation equations to allow for more energy spectra. The method was calibrated directly on noisy data to increase the robustness toward image noise. The new PCD SPR estimation method was tested in theoretical calculations as well as in an experimental setup, using both four and two energy bin PCD‐CT images, and through comparison to two other SPR methods proposed for SECT and DECT. These two methods were also evaluated on PCD‐CT images, full spectrum (one‐bin) or two‐bin images, respectively. In a theoretical framework, we evaluated the effect of patient‐specific tissue variations (density and elemental composition) and image noise on the SPR accuracy; the latter effect was assessed by applying three different noise levels (low, medium, and high noise). SPR estimates derived using real PCD‐CT images were compared to experimentally measured SPRs in nine organic tissue samples, including fat, muscle, and bone tissues. Results For the theoretical calculations, the root‐mean‐square error (RMSE) of the SPR estimation was 0.1% for the new PCD method using both two and four energy bins, compared to 0.2% and 0.7% for the DECT‐ and SECT‐based method, respectively. The PCD method was found to be very robust toward CT image noise, with a RMSE of 2.7% when high noise was added to the CT numbers. Introducing tissue variations, the RMSE only increased to 0.5%; even when adding high image noise to the changed tissues, the RMSE stayed within 3.1%. In the experimental measurements, the RMSE over the nine tissue samples was 0.8% when using two energy bins, and 1.0% for the four‐bin images. Conclusions In all tested cases, the new PCD method produced similar or better results than the SECT‐ and DECT‐based methods, showing an overall improvement of the SPR accuracy. This study thus demonstrated that PCD‐CT scans will be a qualified candidate for SPR estimations.
CT Dental Artifact: Comparison of an Iterative Metal Artifact Reduction Technique with Weighted Filtered Back-Projection
Background Dental hardware produces streak artifacts on computed tomography (CT) images reconstructed with the standard weighted filtered back projection (wFBP) method. Purpose To perform a preliminary evaluation of an iterative metal artifact reduction (IMAR) technique to assess its ability to improve anatomic visualization over wFBP in patients with dental amalgam or other hardware. Material and Methods CT images from patients with dental hardware were reconstructed using wFBP and IMAR software and soft-tissue or bone window/level settings. The anatomy most affected by metal artifacts was identified. Two neuroradiologists determined subjective and objective imaging features, including overall metal artifact score (1 = severe artifacts, 5 = no artifacts), soft-tissue visualization score of the most-compromised structure, and artifact length along the skin surface. CT numbers were used to quantify artifact severity. Results Twenty-four patients were included. IMAR improved overall metal artifact score in 18/24 cases (median =2 ± 0.9 vs. 1 ± 0.6, P < 0.001). Mean CT number in the most-affected anatomical structure significantly improved with IMAR (94.6 vs. 219 HU, P = 0.002) and length of affected skin surface decreased (40.4 mm vs. 118.7 mm, P < 0.001). However, osseous/dental artifactual defects were found in 22/24 cases with IMAR vs. 11/24 with wFBP. Conclusion IMAR software reduced metal artifact both subjectively and objectively and improved visualization of adjacent soft tissues. However, it produced a higher rate of artifactual defects in the teeth and bones than wFBP. Our findings support the use of IMAR as a valuable complement to, but not a replacement for, standard wFBP image reconstruction.
Low‐dose
CT
for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose
CT
Grand Challenge
Purpose Using common datasets, to estimate and compare the diagnostic performance of image‐based denoising techniques or iterative reconstruction algorithms for the task of detecting hepatic metastases. Methods Datasets from contrast‐enhanced CT scans of the liver were provided to participants in an NIH ‐, AAPM ‐ and Mayo Clinic‐sponsored Low Dose CT Grand Challenge. Training data included full‐dose and quarter‐dose scans of the ACR CT accreditation phantom and 10 patient examinations; both images and projections were provided in the training data. Projection data were supplied in a vendor‐neutral standardized format ( DICOM ‐ CT ‐ PD ). Twenty quarter‐dose patient datasets were provided to each participant for testing the performance of their technique. Images were provided to sites intending to perform denoising in the image domain. Fully preprocessed projection data and statistical noise maps were provided to sites intending to perform iterative reconstruction. Upon return of the denoised or iteratively reconstructed quarter‐dose images, randomized, blinded evaluation of the cases was performed using a Latin Square study design by 11 senior radiology residents or fellows, who marked the locations of identified hepatic metastases. Markings were scored against reference locations of clinically or pathologically demonstrated metastases to determine a per‐lesion normalized score and a per‐case normalized score (a faculty abdominal radiologist established the reference location using clinical and pathological information). Scores increased for correct detections; scores decreased for missed or incorrect detections. The winner for the competition was the entry that produced the highest total score (mean of the per‐lesion and per‐case normalized score). Reader confidence was used to compute a Jackknife alternative free‐response receiver operating characteristic ( JAFROC ) figure of merit, which was used for breaking ties. Results 103 participants from 90 sites and 26 countries registered to participate. Training data were shared with 77 sites that completed the data sharing agreements. Subsequently, 41 sites downloaded the 20 test cases, which included only the 25% dose data ( CTDI vol = 3.0 ± 1.8 mG y, SSDE = 3.5 ± 1.3 mG y). 22 sites submitted results for evaluation. One site provided binary images and one site provided images with severe artifacts; cases from these sites were excluded from review and the participants removed from the challenge. The mean (range) per‐lesion and per‐case normalized scores were −24.2% (−75.8%, 3%) and 47% (10%, 70%), respectively. Compared to reader results for commercially reconstructed quarter‐dose images with no noise reduction, 11 of the 20 sites showed a numeric improvement in the mean JAFROC figure of merit. Notably two sites performed comparably to the reader results for full‐dose commercial images. The study was not designed for these comparisons, so wide confidence intervals surrounded these figures of merit and the results should be used only to motivate future testing. Conclusion Infrastructure and methodology were developed to rapidly estimate observer performance for liver metastasis detection in low‐dose CT examinations of the liver after either image‐based denoising or iterative reconstruction. The results demonstrated large differences in detection and classification performance between noise reduction methods, although the majority of methods provided some improvement in performance relative to the commercial quarter‐dose images with no noise reduction applied.